6GK5788-2FC00-1AA0 SCALANCE W788C-2 RJ45 CONTROLLER-BASED

Product Code: 6GK5788-2FC00-1AA0

Availability: In Stock

Price: $100,000,000,000.00
Artikelnummer 6GK5788-2FC00-1AA0
Product type designation SCALANCE W788C-2 RJ45
Product description
IWLAN ACCESS POINT, SCALANCE W788C-2 RJ45, FOR USE WITH IWLAN-CONTROLLER, 2 RADIOS, 6 R-SMA ANT.CONNECT., IEEE 802.11A/B/G/H/N, 2.4/5GHZ, BRUTTO 450 MBIT/S PRO RADIO, 1 X RJ45 (MAX. 1 GBIT/S), POE, 2X24VDC, IP30 (-20-+60 DGR C), POE, WPA2/802.11I/E, NOTE NAT. APPROVALS CONTROLLER! SCOPE OF SUPPLY: MANUALS ON CD ROM GERMAN/ENGLISH, 2 X TERMINAL BLOCK
Transmission rate
Transfer rate
● with WLAN / maximum 450 Mbit/s
● for Industrial Ethernet 10 Mbit/s, 1000 Mbit/s
Interfaces
Number of electrical connections
● for network components or terminal equipment 1
● for power supply 1
● for redundant voltage supply 1
Design of the electrical connection
● for network components or terminal equipment RJ45 socket
● for power supply 4-pole screw terminal, PoE
design of the removable storage
● C-PLUG No
● KEY-PLUG No
Interfaces / wireless
Number of radio cards / permanently installed 2
Transmission mode / for multiple input multiple output (MIMO) 3x3
Number of spatial streams 3
Number of electrical connections / for external antenna(s) 6
Design of the electrical connection / for external antenna(s) R-SMA (socket)
Product property / external antenna can be mounted directly on device Yes
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltage DC
Supply voltage / 1
● from terminal block 19.2 V
Supply voltage / 2
● from terminal block 28.8 V
Supply voltage
● from Power-over-Ethernet acc. to IEEE802.3at for type 1 and IEEE802.3af 48 V
● from Power-over-Ethernet acc. to IEEE802.3at for type 2 50 V
Consumed current
● for DC / at 24 V / typical 0.63 A
● with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af / typical 0.22 A
● with Power-over-Ethernet according to IEEE802.3at for type 2 / typical 0.3 A
Active power loss
● for DC / at 24 V / typical 15 W
● with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af / typical 10.7 W
● with Power-over-Ethernet according to IEEE802.3at for type 2 / typical 15 W
Permitted ambient conditions
Ambient temperature
● during operation -20 ... +60 °C
● during storage -40 ... +85 °C
● during transport -40 ... +85 °C
Relative humidity / at 25 °C / without condensation / during operation / maximum 90 %
Ambient condition / for operation When used under hazardous conditions (Zone 2), the SCALANCE W788-x or W748-x product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529.
Protection class IP IP30
Design, dimensions and weight
Width / of the enclosure / without antenna 200 mm
Height / of the enclosure / without antenna 158 mm
Depth / of the enclosure / without antenna 79 mm
Net weight 1.7 kg
Mounting type For mounting on 35 mm DIN rail, an additional mounitng adapter is required
● S7-300 rail mounting Yes
● S7-1500 rail mounting Yes
● wall mounting Yes
Wireless frequencies
Radio frequency
● for WLAN in 2.4 GHz frequency band 2.41 ... 2.48 GHz
● for WLAN in 5 GHz frequency band 4.9 ... 5.8 GHz
Product properties, functions, components / general
Product function / Access Point Mode Yes
Product function / Client Mode No
Number of SSIDs 16
Product functions / management, configuration
Product function
● operation with IWLAN controller Yes
● operation with Enterasys WLAN controller Yes
Product functions / DHCP
Product function
● DHCP client Yes
Product functions / Time
Protocol / is supported
● SIMATIC Time No
Standards, specifications, approvals
Standard
● for FM FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4
● for hazardous zone EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X
● for safety / from CSA and UL UL 60950-1 CSA C22.2 No. 60950-1
● for hazardous zone / from CSA and UL ANSI/ISA 12.12.01-2013, CAN/CSA C22.2 No.213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC
Certificate of suitability
● EC declaration of conformity Yes
● CE marking Yes
● C-Tick Yes
● CCC No
● E1 approval Yes
● Railway application in accordance with EN 50155 No
● Fire protection in accordance with EN 45545-2 No
● NEMA TS2 No
● IEC 61375 No
● IEC 61850-3 No
● NEMA4X No
● Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af Yes
● Power-over-Ethernet according to IEEE802.3at for type 2 Yes
Standard for wireless communication
● IEEE 802.11a Yes
● IEEE 802.11b Yes
● IEEE 802.11e Yes
● IEEE 802.11g Yes
● IEEE 802.11h Yes
● IEEE 802.11i Yes
● IEEE 802.11n Yes
Wireless approval You will find the current list of countries at: www.siemens.de/funkzulassungen
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS) No
● Bureau Veritas (BV) No
● Det Norske Veritas (DNV) No
● Germanische Lloyd (GL) No
● Lloyds Register of Shipping (LRS) No
● Nippon Kaiji Kyokai (NK) No
● Polski Rejestr Statkow (PRS) No
Accessories
accessories 24 V DC screw terminal and screw terminal for digital input and output included in the scope of delivery
Further Information / Internet Links
Internet-Link
● to website: TIA Selection Tool http://www.siemens.com/tia-selection-tool
● to the website: IWLAN http://www.siemens.com/iwlan
● to website: Industry Mall https://mall.industry.siemens.com
● to website: Information and Download Center http://www.siemens.com/automation/net/catalog
● to website: Image database http://automation.siemens.com/bilddb
● to website: CAx Download Manager http://www.siemens.com/cax
● to website: Industry Online Support http://support.automation.siemens.com
Security information
Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4)
last modified: 14.11.2014
Date
20.11.2014
Changes preserved
© Copyright Siemens AG 2014

Write a review

Note: HTML is not translated!

Rating: Bad Good

Enter the code in the box below: