Product type designation |
SCALANCE W786-2 SFP |
Product description |
|
|
IWLAN ACCESS POINT, SCALANCE W786-2 SFP, ONLY FOR USE IN USA, 2 RADIOS,6 R-SMA ANT. CONNECT., IEEE 802.11A/B/G/H/N, 2.4/5GHZ, BRUTTO 450 MBIT/S PER RADIO, 2 X SFP (MAX. 1 GBIT/S) SWITCH, 24VDC, IP65 (-40-+60 DGR C), TEMP. RANGE DEPENDS ON SFP WPA2/802.11I/E, NOTE NATIONAL APPROVALS! SCOPE OF SUPPLY: MANUALS ON CD-ROM, GERMAN / ENGLISH, 1 X TERMINAL BLOCK. |
Transmission rate |
Transfer rate |
|
● with WLAN / maximum |
450 Mbit/s |
● for Industrial Ethernet |
1000 Mbit/s, 1000 Mbit/s |
Interfaces |
Number of electrical connections |
|
● for power supply |
1 |
● for redundant voltage supply |
0 |
Design of the electrical connection |
|
● for power supply |
2-pole connector (24 V DC) or optionally available power supply adapter (4-pole 24 V DC or 3-pole 110 to 230 V AC) |
Number of optical interfaces |
|
● for fiber optic cable / at 100 Mbit/s |
2 |
● for fiber optic cable / at 1000 Mbit/s |
2 |
Design of the optical interface |
|
● for fiber optic cable / at 100 Mbit/s |
SFP slot |
● for fiber optic cable / at 1000 Mbit/s |
SFP slot |
design of the removable storage |
|
● C-PLUG |
Yes |
● KEY-PLUG |
Yes |
Interfaces / wireless |
Number of radio cards / permanently installed |
2 |
Transmission mode / for multiple input multiple output (MIMO) |
3x3 |
Number of spatial streams |
3 |
Number of electrical connections / for external antenna(s) |
6 |
Design of the electrical connection / for external antenna(s) |
R-SMA (socket) |
Product property / external antenna can be mounted directly on device |
No |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage |
DC |
Supply voltage / 1 |
|
● from terminal block |
19.2 V |
Supply voltage / 2 |
|
● from terminal block |
28.8 V |
Supply voltage |
|
● from optional integrable power supply |
|
— with AC |
100 ... 240 V |
— for DC |
12 ... 24 V |
Permitted ambient conditions |
Ambient temperature |
|
● during operation |
-40 ... +60 °C |
● during storage |
-40 ... +85 °C |
● during transport |
-40 ... +85 °C |
Relative humidity / at 25 °C / without condensation / during operation / maximum |
100 % |
Ambient condition / for operation |
When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
Protection class IP |
IP65 |
Design, dimensions and weight |
Width / of the enclosure / without antenna |
251 mm |
Height / of the enclosure / without antenna |
251 mm |
Depth / of the enclosure / without antenna |
72 mm |
Net weight |
2.24 kg |
Mounting type |
For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
● S7-1500 rail mounting |
No |
● wall mounting |
Yes |
Wireless frequencies |
Radio frequency |
|
● for WLAN in 2.4 GHz frequency band |
2.41 ... 2.48 GHz |
● for WLAN in 5 GHz frequency band |
4.9 ... 5.8 GHz |
Product properties, functions, components / general |
Product function / Access Point Mode |
Yes |
Product function / Client Mode |
Yes |
Number of SSIDs |
16 |
Product function |
|
● Dual Client |
No |
● iPCF Access Point |
Yes; Only in combination with the ''KEY-PLUG W780 iFeatures'' |
● iPCF client |
Yes; Only in combination with the ''KEY-PLUG W780 iFeatures'' or ''KEY-PLUG W740 iFeatures'' |
● iPCF-MC Access Point |
No; Only in combination with the ''KEY-PLUG W780 iFeatures'' |
● iPCF-MC client |
No; Only in combination with ''KEY-PLUG W780 iFeatures'' or ''KEY-PLUG W740 iFeatures'' |
Number of iPCF-capable radio modules |
2 |
Product function / iREF |
No; In combination only with ''KEY-PLUG W780 iFeatures'' |
Number of iREF-capable radio modules |
2 |
Product functions / management, configuration |
Number of manageable IP addresses / in client |
8 |
Product function |
|
● CLI |
Yes |
● web-based management |
Yes |
● MIB support |
Yes |
● TRAPs via email |
Yes |
● Configuration with STEP 7 |
No |
● configuration with STEP 7 in the TIA Portal |
No |
● operation with IWLAN controller |
No |
● operation with Enterasys WLAN controller |
No |
● forced roaming with IWLAN |
Yes |
● WDS |
Yes |
Protocol / is supported |
|
● Address Resolution Protocol (ARP) |
Yes |
● ICMP |
Yes |
● Telnet |
Yes |
● HTTP |
Yes |
● HTTPS |
Yes |
● TFTP |
Yes |
● DCP |
Yes |
● LLDP |
Yes |
Identification & maintenance function |
|
● I&M0 - device-specific information |
Yes |
● I&M1 – higher-level designation/location designation |
Yes |
Product functions / Diagnosis |
Product function |
|
● PROFINET IO diagnosis |
No |
● Link Check |
No |
● connection monitoring IP-Alive |
No |
● localization via Aeroscout |
No |
● SysLog |
Yes |
Protocol / is supported |
|
● SNMP v1 |
Yes |
● SNMP v2 |
Yes |
● SNMP v3 |
Yes |
Product functions / VLAN |
Product function |
|
● function VLAN with IWLAN |
Yes |
Product functions / DHCP |
Product function |
|
● DHCP client |
Yes |
● in Client Mode / DHCP server via LAN |
No |
Product functions / Redundancy |
Protocol / is supported |
|
● STP/RSTP |
Yes |
Product functions / Security |
Product function |
|
● Management security, ACL-IP based |
Yes |
● IEEE 802.1x (radius) |
Yes |
● NAT/NAPT |
No |
● access protection according to IEEE802.11i |
Yes |
● WPA/WPA2 |
Yes |
● TKIP/AES |
Yes |
Protocol / is supported |
|
● SSH |
Yes |
Product functions / Time |
Protocol / is supported |
|
● SNTP |
Yes |
● SIMATIC Time |
Yes |
Standards, specifications, approvals |
Standard |
|
● for FM |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
● for hazardous zone |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
● for safety / from CSA and UL |
UL 60950-1 CSA C22.2 No. 60950-1 |
● for hazardous zone / from CSA and UL |
ANSI/ISA 12.12.01-2013, CAN/CSA C22.2 No.213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC |
Certificate of suitability |
|
● EC declaration of conformity |
Yes |
● CE marking |
Yes |
● C-Tick |
Yes |
● CCC |
No |
● E1 approval |
Yes |
● Railway application in accordance with EN 50155 |
No |
● Fire protection in accordance with EN 45545-2 |
No |
● NEMA TS2 |
No |
● IEC 61375 |
No |
● IEC 61850-3 |
No |
● NEMA4X |
Yes |
● Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af |
No |
● Power-over-Ethernet according to IEEE802.3at for type 2 |
No |
Standard for wireless communication |
|
● IEEE 802.11a |
Yes |
● IEEE 802.11b |
Yes |
● IEEE 802.11e |
Yes |
● IEEE 802.11g |
Yes |
● IEEE 802.11h |
Yes |
● IEEE 802.11i |
Yes |
● IEEE 802.11n |
Yes |
Wireless approval |
You will find the current list of countries at: www.siemens.de/funkzulassungen |
Marine classification association |
|
● American Bureau of Shipping Europe Ltd. (ABS) |
No |
● Bureau Veritas (BV) |
No |
● Det Norske Veritas (DNV) |
No |
● Germanische Lloyd (GL) |
No |
● Lloyds Register of Shipping (LRS) |
No |
● Nippon Kaiji Kyokai (NK) |
No |
● Polski Rejestr Statkow (PRS) |
No |
Accessories |
accessories |
24 V DC screw terminal included in scope of delivery |
Further Information / Internet Links |
Internet-Link |
|
● to website: TIA Selection Tool |
http://www.siemens.com/tia-selection-tool |
● to the website: IWLAN |
http://www.siemens.com/iwlan |
● to website: Industry Mall |
https://mall.industry.siemens.com |
● to website: Information and Download Center |
http://www.siemens.com/automation/net/catalog |
● to website: Image database |
http://automation.siemens.com/bilddb |
● to website: CAx Download Manager |
http://www.siemens.com/cax |
● to website: Industry Online Support |
http://support.automation.siemens.com |
Security information |
Security information |
Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4) |
last modified: |
01.12.2014 |
Date 14.12.2014 |
Changes preserved © Copyright Siemens AG 2014 |