6GK5748-1FC00-0AB0 SCALANCE W748-1 RJ45 (USA-VERSION)

Product Code: 6GK5748-1FC00-0AB0

Availability: In Stock

Price: $100,000,000,000.00
Artikelnummer 6GK5748-1FC00-0AB0
Product type designation SCALANCE W748-1 RJ45
Product description
IWLAN CLIENT, SCALANCE W748-1 RJ45, ONLY FOR USE IN USA, 1 RADIO, 3 R-SMA ANT. CONNECT., IEEE 802.11A/B/G/H/N, 2.4/5GHZ, BRUTTO 450 MBIT/S PRO RADIO, 1 X RJ45 (MAX. 1 GBIT/S), POE, 2X24VDC, IP30 (-20-+60 DGR C), POE, WPA2/802.11I/E, SIGNALLING CONTACT, PLEASE NOTE NATIONAL APPROVALS! SCOPE OF SUPPLY: MANUALS ON CD ROM GERMAN/ENGLISH, 2 X TERMINAL BLOCK
Transmission rate
Transfer rate
● with WLAN / maximum 450 Mbit/s
● for Industrial Ethernet 10 Mbit/s, 1000 Mbit/s
Interfaces
Number of electrical connections
● for network components or terminal equipment 1
● for power supply 1
● for redundant voltage supply 1
Design of the electrical connection
● for network components or terminal equipment RJ45 socket
● for power supply 4-pole screw terminal, PoE
design of the removable storage
● C-PLUG Yes
● KEY-PLUG Yes
Interfaces / wireless
Number of radio cards / permanently installed 1
Transmission mode / for multiple input multiple output (MIMO) 3x3
Number of spatial streams 3
Number of electrical connections / for external antenna(s) 3
Design of the electrical connection / for external antenna(s) R-SMA (socket)
Product property / external antenna can be mounted directly on device Yes
Signal-Inputs/outputs
Number of digital inputs 1
Number of digital outputs 1
Design of the electrical connection / at the digital inputs/outputs 4-pole screw terminal
Signal range / at digital input 24 V DC, safety extra-low voltage
Signal range / at digital output 24 V DC /1 A
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltage DC
Supply voltage / 1
● from terminal block 19.2 V
Supply voltage / 2
● from terminal block 28.8 V
Supply voltage
● from Power-over-Ethernet acc. to IEEE802.3at for type 1 and IEEE802.3af 48 V
● from Power-over-Ethernet acc. to IEEE802.3at for type 2 50 V
Consumed current
● for DC / at 24 V / typical 0.45 A
● with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af / typical 0.22 A
● with Power-over-Ethernet according to IEEE802.3at for type 2 / typical 0.21 A
Active power loss
● for DC / at 24 V / typical 10.7 W
● with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af / typical 10.7 W
● with Power-over-Ethernet according to IEEE802.3at for type 2 / typical 10.7 W
Permitted ambient conditions
Ambient temperature
● during operation -20 ... +60 °C
● during storage -40 ... +85 °C
● during transport -40 ... +85 °C
Relative humidity / at 25 °C / without condensation / during operation / maximum 90 %
Ambient condition / for operation When used under hazardous conditions (Zone 2), the SCALANCE W788-x or W748-x product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529.
Protection class IP IP30
Design, dimensions and weight
Width / of the enclosure / without antenna 200 mm
Height / of the enclosure / without antenna 158 mm
Depth / of the enclosure / without antenna 79 mm
Net weight 1.7 kg
Mounting type
● S7-300 rail mounting Yes
● S7-1500 rail mounting Yes
● wall mounting Yes
Wireless frequencies
Radio frequency
● for WLAN in 2.4 GHz frequency band 2.41 ... 2.48 GHz
● for WLAN in 5 GHz frequency band 4.9 ... 5.8 GHz
Product properties, functions, components / general
Product function / Access Point Mode No
Product function / Client Mode Yes
Product function
● Dual Client No
● iPCF client Yes; Only in combination with the ''KEY-PLUG W780 iFeatures'' or ''KEY-PLUG W740 iFeatures''
● iPCF-MC client No; Only in combination with ''KEY-PLUG W780 iFeatures'' or ''KEY-PLUG W740 iFeatures''
Number of iPCF-capable radio modules 1
Product functions / management, configuration
Number of manageable IP addresses / in client 8
Product function
● CLI Yes
● web-based management Yes
● MIB support Yes
● TRAPs via email Yes
● Configuration with STEP 7 No
● configuration with STEP 7 in the TIA Portal No
● forced roaming with IWLAN No
● WDS No
Protocol / is supported
● Address Resolution Protocol (ARP) Yes
● ICMP Yes
● Telnet Yes
● HTTP Yes
● HTTPS Yes
● TFTP Yes
● DCP Yes
● LLDP Yes
Identification & maintenance function
● I&M0 - device-specific information Yes
● I&M1 – higher-level designation/location designation Yes
Product functions / Diagnosis
Product function
● PROFINET IO diagnosis No
● Link Check No
● connection monitoring IP-Alive No
● SysLog Yes
Protocol / is supported
● SNMP v1 Yes
● SNMP v2 Yes
● SNMP v3 Yes
Product functions / VLAN
Product function
● function VLAN with IWLAN No
Product functions / DHCP
Product function
● DHCP client Yes
● in Client Mode / DHCP server via LAN No
Product functions / Security
Product function
● Management security, ACL-IP based Yes
● IEEE 802.1x (radius) Yes
● NAT/NAPT No
● access protection according to IEEE802.11i Yes
● WPA/WPA2 Yes
● TKIP/AES Yes
Protocol / is supported
● SSH Yes
Product functions / Time
Protocol / is supported
● SNTP Yes
● SIMATIC Time Yes
Standards, specifications, approvals
Standard
● for hazardous zone EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X
● for safety / from CSA and UL UL 60950-1 CSA C22.2 No. 60950-1
● for hazardous zone / from CSA and UL ANSI/ISA 12.12.01-2013, CAN/CSA C22.2 No.213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC
Certificate of suitability
● EC declaration of conformity Yes
● CE marking Yes
● C-Tick Yes
● CCC No
● E1 approval Yes
● Railway application in accordance with EN 50155 No
● Fire protection in accordance with EN 45545-2 No
● NEMA TS2 No
● IEC 61375 No
● IEC 61850-3 No
● NEMA4X No
● Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af Yes
● Power-over-Ethernet according to IEEE802.3at for type 2 Yes
Standard for wireless communication
● IEEE 802.11a Yes
● IEEE 802.11b Yes
● IEEE 802.11e Yes
● IEEE 802.11g Yes
● IEEE 802.11h Yes
● IEEE 802.11i Yes
● IEEE 802.11n Yes
Wireless approval For operation in the USA, you can find more detailed information at: www.siemens.com/simatic-net/ik-info
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS) No
● Bureau Veritas (BV) No
● Det Norske Veritas (DNV) No
● Germanische Lloyd (GL) No
● Lloyds Register of Shipping (LRS) No
● Nippon Kaiji Kyokai (NK) No
● Polski Rejestr Statkow (PRS) No
Accessories
accessories 24 V DC screw terminal and screw terminal for digital input and output included in the scope of delivery
Further Information / Internet Links
Internet-Link
● to website: Information and Download Center http://www.siemens.com/automation/net/catalog
● to website: Image database http://automation.siemens.com/bilddb
● to website: CAx Download Manager http://www.siemens.com/cax
● to website: Industry Online Support http://support.automation.siemens.com
last modified: 23.10.2014
Date
31.10.2014
Changes preserved
© Copyright Siemens AG 2014

Write a review

Note: HTML is not translated!

Rating: Bad Good

Enter the code in the box below: