Product type designation |
SCALANCE S602 |
|
SCALANCE S602 MODULE FOR PROTECTION OF UNITS AND NETWORKS IN AUTOMATION TECHNOLOGY AND FOR PROTECTION OF INDUSTRIAL COMMUNICATION WITH FIREWALL ADDITIONAL FUNCTIONS: ADDRESS CONVERSION (NAT/NAPT), DHCP-SERVER, SYSLOG, SYMBOL. NAME FOR IP-ADDRESSES, PPPOE, DYNDNS, SNMP (V1+V3) GLOBALE FIREWALL RULES |
Transmission rate |
Transfer rate |
10 Mbit/s, 100 Mbit/s, 1000 Mbit/s |
Interfaces |
Number of electrical/optical connections / for network components or terminal equipment / maximum |
2 |
Number of electrical connections |
|
● for internal network |
1 |
● for external network |
1 |
● for DMZ |
0 |
● for signaling contact |
1 |
● for power supply |
1 |
● for redundant voltage supply |
1 |
Design of the electrical connection |
|
● for internal network |
RJ45 port |
● for external network |
RJ45 port |
● for DMZ |
- |
● for signaling contact |
2-pole terminal block |
● for power supply |
4-pole terminal block |
design of the removable storage / C-PLUG |
Yes |
Signal-Inputs/outputs |
Operating voltage / of the signaling contacts / for DC / Rated value |
24 V |
Operating current / of the signaling contacts / for DC / maximum |
0.1 A |
Supply voltage, current consumption, power loss |
Supply voltage / external |
24 V |
Supply voltage / external |
19.2 ... 28.8 V |
Type of voltage / of the supply voltage |
DC |
Consumed current / maximum |
0.5 A |
Product component / fusing at power supply input |
Yes |
Fuse protection type / at input for supply voltage |
Non-replaceable melting fuse (F 3 A / 32 V) |
Active power loss |
|
● for DC / at 24 V / typical |
6.72 W |
Permitted ambient conditions |
Ambient temperature |
|
● during operation |
-40 ... +60 °C |
● during storage |
-40 ... +80 °C |
● during transport |
-40 ... +80 °C |
Relative humidity / at 25 °C / without condensation / during operation / maximum |
95 % |
Protection class IP |
IP20 |
Design, dimensions and weight |
Design |
compact |
Width |
60 mm |
Height |
125 mm |
Depth |
124 mm |
Net weight |
0.8 kg |
Mounting type |
Screw mounting on horizontal and vertical surfaces |
Mounting type |
|
● 35 mm DIN rail mounting |
Yes |
● S7-300 rail mounting |
Yes |
● wall mounting |
Yes |
Product properties, functions, components / general |
Product function / DynDNS client |
Yes |
Protocol / is supported / PPPoE |
Yes |
Product functions / management, configuration |
Product function / symbolic names for IP addresses |
Yes |
Protocol / is supported |
|
● SNMP v1 |
Yes |
● SNMP v3 |
Yes |
Type of configuration |
SCT: Security Configuration Tool (included in scope of delivery) |
Product functions / Diagnosis |
Product function |
|
● SysLog |
Yes |
● Packet Filter Log |
Yes |
● Audit Log |
Yes |
● System log |
Yes |
Product functions / DHCP |
Product function / DHCP server - internal network |
Yes |
Product functions / Routing |
Product function / Static IP routing |
Yes |
Product functions / Security |
Firewall version |
stateful inspection |
Product function / with VPN connection |
- |
Type of encryption algorithms / with VPN connection |
- |
Type of authentication procedure / with VPN connection |
- |
Type of hashing algorithms / with VPN connection |
- |
Number of possible connections / with VPN connection |
0 |
Number of network nodes / for internal network / with VPN connection |
|
● maximum |
0 |
● Note |
- |
Product function |
|
● Password protection |
Yes |
● Bandwidth limiting |
Yes |
● NAT/NAPT |
Yes |
Product functions / Time |
Product function / pass on time synchronization |
Yes |
Protocol / is supported / NTP |
Yes |
Product component / Hardware real-time clock |
Yes |
Product property / Hardware real-time clock w. battery backup |
Yes |
Standards, specifications, approvals |
Standard |
|
● for hazardous zone |
EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA IIT.., KEMA 07 ATEX 0145 X |
● for safety / from CSA and UL |
UL 60950 / CSA C22.2 No. 60950-00, UL 508 / CSA C22.2 No. 142 |
● for emitted interference |
EN 61000-6-4 : 2007 |
● for interference immunity |
EN 61000-6-2 : 2005 |
Certificate of suitability |
AS/NZS 2064 (Class A), EN 61000-6-2, EN 61000-6-4, marine classification pending |
Certificate of suitability |
|
● CE marking |
Yes |
● C-Tick |
Yes |
Marine classification association |
|
● American Bureau of Shipping Europe Ltd. (ABS) |
No |
● Bureau Veritas (BV) |
No |
● Det Norske Veritas (DNV) |
No |
● Germanische Lloyd (GL) |
No |
● Lloyds Register of Shipping (LRS) |
No |
● Nippon Kaiji Kyokai (NK) |
No |
● Polski Rejestr Statkow (PRS) |
No |
Accessories |
Product expansion / optional / C-PLUG |
Yes |
Further Information / Internet Links |
Internet-Link |
|
● to website: Selector SIMATIC NET SELECTION TOOL |
http://www.siemens.com/snst |
● to website: Industrial communication |
http://www.siemens.com/simatic-net |
● to website: Information and Download Center |
http://www.siemens.com/automation/net/catalog |
● to website: Image database |
http://automation.siemens.com/bilddb |
● to website: CAx Download Manager |
http://www.siemens.com/cax |
● to website: Industry Online Support |
http://support.automation.siemens.com |
last modified: |
23.10.2014 |
Date 30.10.2014 |
Changes preserved © Copyright Siemens AG 2014 |