Product type designation |
Power Supply PS598-1 |
Product description |
|
|
SCALANCE PS598-1 POWER SUPPLY 300 WATT INPUT: AC 85-264 V, INLET CONN. FOR NON-HEATING APPARATUS OUTPUT: DC 24 V TERMINALS OR FOR DIRECT CONNECTING TO SCALANCE X-500 |
Type of current supply |
300 W, input: 85-264 V, output:DC 24 |
Electrical data / Input |
Voltage curve / at input |
1-phase AC |
Supply voltage / with AC |
85 ... 264 V |
Supply voltage / 1 / with AC / Rated value |
230 V |
Design of input / wide range input |
Yes |
Overvoltage category |
Category II (20 A rated branch circuit) |
Buffering time / at rated output current / in the event of power failure / minimum |
16 ms |
Line frequency |
|
● 1 / Rated value |
50 Hz |
● 2 / Rated value |
60 Hz |
Line frequency |
47 ... 63 Hz |
Input current / at rated input voltage 230 V / Rated value |
1.8 A |
Current limitation / of inrush current / at 25 °C / maximum |
40 A |
Fuse protection type / at input |
replaceable |
Electrical data / Output |
Voltage curve / at output |
Controlled, isolated DC voltage |
Output voltage / for DC / Rated value |
24 V |
Display version / for normal operation |
Green LED for 24 V OK and fault LED |
Behavior of the output voltage / when switching on |
Overshoot of Ua < 5 % |
ON-delay time / maximum |
1.5 s |
Voltage increase time / of the output voltage / maximum |
15 ms |
Output current |
|
● Rated value |
12.5 A |
● Rated range |
0 ... 12.5 A |
Active power supplied / typical |
300 W |
Product property / Parallel switching of channels |
Yes |
Number of parallel-switched resources / for increasing the power |
2 |
Efficiency in percent |
87 % |
Active power loss |
39 W |
Electrical data / Closed-loop control |
Relative overall tolerance / of the voltage |
2 % |
Residual ripple / maximum |
0.36 V |
Voltage peak / maximum |
240 V |
Relative control precision / of the output voltage |
|
● On slow fluctuation of input voltage |
0.2 % |
● On slow fluctuation of ohm loading |
0.4 % |
● load step of resistive load 50/100/50 % / typical |
3.25 % |
● with rapid fluctuation of the input voltage by +/- 15% / typical |
0.8 % |
Setting time |
|
● load step 50 to 100% / typical |
2 ms |
● load step 100 to 50% / typical |
2 ms |
Electrical data / Protection and monitoring |
Design of the overvoltage protection / at output |
< 37 V |
Response value current limitation / typical |
1.15 A |
Property of the output / Short-circuit proof |
Yes |
Design of short-circuit protection |
Electronic shutdown, automatic restart |
Galvanic isolation / between entrance and outlet |
Yes |
Galvanic isolation |
Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 |
Operating resource protection class |
Class I |
Leakage current |
|
● maximum |
3 mA |
● typical |
0.858 mA |
Interfaces |
Design of the electrical connection |
|
● at input |
IEC plug |
● at output |
for plugging into basic device or screw terminal in accordance with specification |
Mechanical data |
Design, dimensions and weight |
Width |
446 mm |
Height |
44 mm |
Depth |
140 mm |
Net weight |
1.7 kg |
Product property / of the enclosure / housing for side-by-side mounting |
No |
Mounting type |
Plugged into the basic unit or rack mounted |
● 19-inch installation |
Yes |
● wall mounting |
No |
● Standard rail mounting |
No |
● S7-300 rail mounting |
No |
Permitted ambient conditions |
Ambient temperature |
|
● during operation |
60 °C |
● during storage |
-25 ... +70 °C |
● during transport |
-25 ... +70 °C |
Climate class / acc. to EN 60721 |
Climate class 3K3, without condensation |
Protection class IP |
IP20 |
Standards, specifications, approvals |
Standard |
|
● for safety / from CSA and UL |
UL 60950-1, CSA C22.2 Nr. 60950-1 |
● for emitted interference |
EN 55022 (Class B) |
● for interference immunity |
EN 61000-6-2 |
Certificate of suitability |
EN 55022, EN 61000-6-4 |
● CE marking |
Yes |
● C-Tick |
Yes |
● E1 approval |
No |
● E1 approval |
No |
● Railway application in accordance with EN 50155 |
No |
● Railway application in accordance with EN 50124-1 |
No |
● IEC 61850-3 |
No |
Further Information / Internet Links |
Internet-Link |
|
● to website: Industrial communication |
http://www.siemens.com/simatic-net |
● to website: Information and Download Center |
http://www.siemens.com/automation/net/catalog |
● to website: Image database |
http://automation.siemens.com/bilddb |
● to website: CAx Download Manager |
http://www.siemens.com/cax |
● to website: Industry Online Support |
http://support.automation.siemens.com |
last modified: |
23.10.2014 |
Date 12.11.2014 |
Changes preserved © Copyright Siemens AG 2014 |