Product type designation |
SCALANCE PE408PoE |
Product description |
|
|
PE408POE PORT EXTENDER FOR SCALANCE XM-400 MANAGED MODULAR IE SWITCH; EXPANSION: 8 X 10/100/1000 MBIT/S RJ45 WITH UP TO ,8 PORTS POE ACCORDING TO IEEE802.3AT; FOR POE SEPARATE POWER SUPPLY REQUIRED |
Transmission rate |
Transfer rate |
10 Mbit/s, 100 Mbit/s, 1000 Mbit/s |
Interfaces |
Number of electrical/optical connections |
|
● for network components or terminal equipment / maximum |
8 |
Number of electrical connections |
|
● for network components or terminal equipment |
8 |
● for Power-over-Ethernet / for network components or terminal equipment |
8 |
Design of the electrical connection |
|
● for network components or terminal equipment |
RJ45 port |
● for Power-over-Ethernet / for network components or terminal equipment |
RJ45 port |
● for power supply |
2-pole terminal block |
Number of extender expansion interfaces |
2 |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage |
DC |
Supply voltage |
|
● external |
54 V |
● external |
51.3 ... 56.7 V |
Product component / fusing at power supply input |
Yes |
Consumed current / maximum |
0.2 A |
Active power loss |
|
● for DC / at 24 V |
4.8 W |
Permitted ambient conditions |
Ambient temperature |
|
● during operation |
-40 ... +60 °C |
● during storage |
-40 ... +85 °C |
● during transport |
-40 ... +85 °C |
Relative humidity |
|
● at 25 °C / without condensation / during operation / maximum |
95 % |
Protection class IP |
IP20 |
Design, dimensions and weight |
Design |
SIMATIC S7-1500 device design |
Width |
70 mm |
Height |
147 mm |
Depth |
125 mm |
Net weight |
0.7 kg |
Mounting type |
|
● 19-inch installation |
No |
● 35 mm DIN rail mounting |
Yes |
● wall mounting |
No |
● S7-300 rail mounting |
Yes |
● S7-1500 rail mounting |
Yes |
Standards, specifications, approvals |
Standard |
|
● for FM |
FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
● for hazardous zone |
EN 60079-0: 2009, EN60079-15: 2010, II 3 G Ex nA IIC T4 Gc, KEMA 07 ATEX 0145 X |
● for safety / from CSA and UL |
UL 60950-1, CSA C22.2 No. 60950-1-03 |
● for hazardous zone / from CSA and UL |
ISA 12.12.01-2012 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
● for emitted interference |
EN 61000-6-4 (Class A) |
● for interference immunity |
EN 61000-6-2 |
Certificate of suitability |
EN 61000-6-2, EN 61000-6-4 |
● CE marking |
Yes |
● C-Tick |
Yes |
● KC approval |
No |
● E1 approval |
No |
● E1 approval |
No |
Further Information / Internet Links |
Internet-Link |
|
● to website: Selector SIMATIC NET SELECTION TOOL |
http://www.siemens.com/snst |
● to website: Industrial communication |
http://www.siemens.com/simatic-net |
● to website: Information and Download Center |
http://www.siemens.com/automation/net/catalog |
● to website: Image database |
http://automation.siemens.com/bilddb |
● to website: CAx Download Manager |
http://www.siemens.com/cax |
● to website: Industry Online Support |
http://support.automation.siemens.com |
Security information |
Security information |
Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4) |
last modified: |
23.10.2014 |
Date 03.11.2014 |
Changes preserved © Copyright Siemens AG 2014 |