6GK5204-2BC10-2CA2 SCALANCE X204-2LD TS

Product Code: 6GK5204-2BC10-2CA2

Availability: In Stock

Price: $100,000,000,000.00
Artikelnummer 6GK5204-2BC10-2CA2
Product type designation SCALANCE X204-2LD TS
Product description
SCALANCE X204-2LD TS; MANAGED IE SWITCH; 4 X 10/100MBIT/S RJ45 PORTS; 2 X 100MBIT/S SINGLE MODE BFOC; LED-DIAGNOSTICS, FAULT SIGNAL CONTACT WITH SET-BUTTON, REDUNDANT POWER SUPPLY PROFINET-IO DEVICE, NETWORK- MANAGEMENT; INTEGR. REDUNDANCY MANAGER; INCL. ELECTRON. MANUAL ON CD, C-PLUG OPTIONAL
Transmission rate
Transfer rate 10 Mbit/s, 100 Mbit/s
Interfaces
Number of electrical/optical connections
● for network components or terminal equipment / maximum 6
Number of electrical connections
● for network components or terminal equipment 4
● for signaling contact 1
● for power supply 1
● for redundant voltage supply 1
Design of the electrical connection
● for network components or terminal equipment RJ45 port
● for signaling contact 2-pole terminal block
● for power supply 4-pole terminal block
Number of optical interfaces
● for fiber optic cable / at 100 Mbit/s 2
Design of the optical interface
● for fiber optic cable / at 100 Mbit/s BFOC port (singlemode up to 26 km)
Connectable optical power relative to 1 mW
● of the transmitter output / minimum -15 dB
● of the transmitter output / maximum -7 dB
Optical sensitivity relating to 1 mW / of the receiver input / minimum -34 dB
Damping ratio / of the FOC transmission link / minimum necessary 0 dB
Range / at the optical interface / depending on the optical fiber used 0 ... 26 km
design of the removable storage / C-PLUG Yes
Signal-Inputs/outputs
Operating voltage / of the signaling contacts
● for DC / Rated value 24 V
Operating current / of the signaling contacts
● for DC / maximum 0.05 A
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltage DC
Supply voltage
● external 12 V
● external 10 ... 30 V
Supply voltage
● for DC 24 V
● for DC / Rated value / minimum 10 V
● for DC / Rated value / maximum 30 V
Product component / fusing at power supply input Yes
Fuse protection type / at input for supply voltage 3 A / 32 V
Consumed current / maximum 0.6 A
Active power loss
● for DC / at 24 V 6.6 W
Permitted ambient conditions
Ambient temperature
● during operation -40 ... +60 °C
● during storage -40 ... +70 °C
● during transport -40 ... +70 °C
● Note If the IE switch X-204-2LD TS is installed horizontally a maximum ambient temperature of +40 °C is permitted
Relative humidity
● at 25 °C / without condensation / during operation / maximum 95 %
Ambient condition / for operation Conformal coating, yes
Coating Conformal Coating, yes
Protection class IP IP20
Design, dimensions and weight
Design compact
Width 60 mm
Height 125 mm
Depth 124 mm
Net weight 0.78 kg
Mounting type
● 35 mm DIN rail mounting Yes
● wall mounting Yes
● S7-300 rail mounting Yes
● S7-1500 rail mounting No
Product properties, functions, components / general
Cascading in the case of a redundant ring / at reconfiguration time of <~0.3~s 100
Cascading in cases of star topology Any (depending only on signal propagation time)
Product functions / management, configuration
Product function
● CLI Yes
● web-based management Yes
● MIB support Yes
● TRAPs via email Yes
● Configuration with STEP 7 Yes
● Port mirroring Yes
● multiport mirroring No
● with IRT / PROFINET IO switch No
● PROFINET IO diagnosis Yes
● switch-managed Yes
Protocol / is supported
● Telnet Yes
● HTTP Yes
● HTTPS Yes
● TFTP Yes
● FTP Yes
● BOOTP No
● DCP Yes
● LLDP Yes
Identification & maintenance function
● I&M0 - device-specific information Yes
● I&M1 – higher-level designation/location designation Yes
Protocol / is supported
● SNMP v1 Yes
● SNMP v2 Yes
● SNMP v3 Yes
Product functions / Diagnosis
Product function
● Port diagnostics Yes
● Statistics Packet Size Yes
● Statistics packet type Yes
● Error statistics Yes
Product functions / DHCP
Product function
● DHCP client Yes
Product functions / Redundancy
Product function
● Ring redundancy Yes
● High Speed Redundancy Protocol (HRP) Yes
● high speed redundancy protocol (HRP) with redundancy manager Yes
● high speed redundancy protocol (HRP) with standby redundancy No
● Media Redundancy Protocol (MRP) Yes
● media redundancy protocol (MRP) with redundancy manager Yes
● Passive listening Yes
Product functions / Security
Protocol / is supported
● SSH Yes
Product functions / Time
Product function
● SICLOCK support Yes
Protocol / is supported
● NTP No
● SNTP Yes
Standards, specifications, approvals
Standard
● for FM FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4
● for hazardous zone EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X
● for safety / from CSA and UL UL 60950-1, CSA C22.2 No. 60950-1
● for hazardous zone / from CSA and UL ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4
● for emitted interference EN 61000-6-4 (Class A)
● for interference immunity EN 61000-6-2
Certificate of suitability EN 61000-6-2, EN 61000-6-4
● CE marking Yes
● C-Tick Yes
● KC approval Yes
● Railway application in accordance with EN 50155 Yes
● Railway application in accordance with EN 50124-1 No
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS) No
● Bureau Veritas (BV) No
● Det Norske Veritas (DNV) No
● Germanische Lloyd (GL) No
● Lloyds Register of Shipping (LRS) No
● Nippon Kaiji Kyokai (NK) No
● Polski Rejestr Statkow (PRS) No
MTBF / at 40 °C 85.01 y
Further Information / Internet Links
Internet-Link
● to website: Selector SIMATIC NET SELECTION TOOL http://www.siemens.com/snst
● to website: Industrial communication http://www.siemens.com/simatic-net
● to website: Industry Mall https://mall.industry.siemens.com
● to website: Information and Download Center http://www.siemens.com/automation/net/catalog
● to website: Image database http://automation.siemens.com/bilddb
● to website: CAx Download Manager http://www.siemens.com/cax
● to website: Industry Online Support http://support.automation.siemens.com
Security information
Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4)
last modified: 07.11.2014
Date
28.11.2014
Changes preserved
© Copyright Siemens AG 2014

Write a review

Note: HTML is not translated!

Rating: Bad Good

Enter the code in the box below: