6GK5204-0BS00-3LA3 SCALANCE X204RNA EEC (PRP)

Product Code: 6GK5204-0BS00-3LA3

Availability: In Stock

Price: $530.88
Artikelnummer 6GK5204-0BS00-3LA3
Product type designation SCALANCE X204RNA EEC
Product description
SCALANCE X204RNA EEC; REDUNDANT NETWORK ACCESS FOR PRP NETWORKS; 2 X 100MBIT/S RJ45 PORTS; 2 X 100MBIT/S COMBO-PORTS; LED-DIAGNOSTICS; FAULT SIGNAL CONTACT WITH SET BUTTON; REDUNDANT POWER SUPPLY, NETZWORK MANAGEMENT; INCL. ELECTRONIC MANUAL ON CD, C-PLUG OPTIONAL
Transmission rate
Transfer rate 100 Mbit/s
Interfaces
Number of electrical/optical connections
● for network components or terminal equipment / maximum 4
● as combo port / for network components or terminal equipment 2
Number of electrical connections
● for network components or terminal equipment 2
● for signaling contact 1
● for power supply 1
● for redundant voltage supply 1
Design of electrical/optical connections / for network components or terminal equipment SFP
Design of the electrical connection
● for network components or terminal equipment RJ45 port
● for signaling contact 3-pole terminal block
● for power supply 3-pole terminal block
Number of optical interfaces
● for fiber optic cable / at 100 Mbit/s 2
Design of the optical interface
● for fiber optic cable / at 100 Mbit/s SFF port
design of the removable storage / C-PLUG Yes
Signal-Inputs/outputs
Operating voltage / of the signaling contacts
● with AC / Rated value 230 V
● for DC / Rated value 24 V
Operating current / of the signaling contacts
● with AC / maximum 0.1 A
● for DC / maximum 0.1 A
Supply voltage, current consumption, power loss
Supply voltage
● with AC 230 V
● with AC / Rated value 85 ... 276 V
Supply voltage / 2 / Rated value
● Type of voltage / 2 / of the supply voltage DC
Supply voltage
● for DC 24 V
● for DC / Rated value / minimum 19.2 V
● for DC / Rated value / maximum 300 V
Product component / fusing at power supply input Yes
Fuse protection type / at input for supply voltage 1,25 A
Consumed current / maximum 0.25 A
Active power loss
● for DC / at 24 V 6 W
Permitted ambient conditions
Ambient temperature
● during operation -40 ... +70 °C
● during storage -40 ... +70 °C
● during transport -40 ... +70 °C
● Note A maximum operating temperature of +85 °C is permissible for a duration of 16 hours
Relative humidity
● at 25 °C / without condensation / during operation / maximum 95 %
Protection class IP IP20
Design, dimensions and weight
Design compact
Width 70 mm
Height 147 mm
Depth 123 mm
Net weight 0.78 kg
Mounting type
● 35 mm DIN rail mounting Yes
● wall mounting No
● S7-300 rail mounting No
● S7-1500 rail mounting No
Product functions / management, configuration
Product function
● CLI Yes
● web-based management Yes
● MIB support Yes
● TRAPs via email Yes
● Configuration with STEP 7 No
● Port mirroring No
● multiport mirroring No
● with IRT / PROFINET IO switch No
● PROFINET IO diagnosis No
● switch-managed No
Protocol / is supported
● Telnet No
● HTTP Yes
● HTTPS Yes
● TFTP No
● FTP No
● BOOTP No
● GMRP No
● DCP No
● LLDP No
● IGMP (snooping/querier) No
Identification & maintenance function
● I&M0 - device-specific information Yes
● I&M1 – higher-level designation/location designation Yes
Protocol / is supported
● SNMP v1 Yes
● SNMP v2 Yes
● SNMP v3 Yes
Product functions / Diagnosis
Product function
● Port diagnostics Yes
● Statistics Packet Size Yes
● Statistics packet type Yes
● Error statistics Yes
Product functions / Redundancy
Product function
● Ring redundancy No
● High Speed Redundancy Protocol (HRP) No
● high speed redundancy protocol (HRP) with redundancy manager No
● high speed redundancy protocol (HRP) with standby redundancy No
● Media Redundancy Protocol (MRP) No
● media redundancy protocol (MRP) with redundancy manager No
● Parallel Redundancy Protocol (PRP) Yes
● High-availability Seamless Redundancy (HSR) No
● High-availability Seamless Redundancy (HSR) and Parallel Redundancy Protocol (PRP) coupling No
● Passive listening No
Product functions / Security
Protocol / is supported
● SSH Yes
Product functions / Time
Product function
● SICLOCK support No
Protocol / is supported
● NTP No
● SNTP Yes
Standards, specifications, approvals
Standard
● for EMC IEC 61850, IEEE 1613
● for FM FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4
● for hazardous zone EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X
● for safety / from CSA and UL UL 508, CSA C22.2 No. 142-M1987
● for emitted interference EN 61000-6-4:2001 (Class A)
● for interference immunity EN 61000-6-4:2001
Certificate of suitability EN 61000-6-4:2001
● CE marking Yes
● C-Tick Yes
● KC approval Yes
● Railway application in accordance with EN 50155 No
● Railway application in accordance with EN 50124-1 No
● IEC 61850-3 Yes
● IEEE 1613 Yes
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS) No
● Bureau Veritas (BV) No
● Det Norske Veritas (DNV) No
● Germanische Lloyd (GL) No
● Lloyds Register of Shipping (LRS) No
● Nippon Kaiji Kyokai (NK) No
● Polski Rejestr Statkow (PRS) No
MTBF / at 40 °C 67.64 y
Accessories
Product expansion / optional / C-PLUG Yes
Further Information / Internet Links
Internet-Link
● to website: Selector SIMATIC NET SELECTION TOOL http://www.siemens.com/snst
● to website: Industrial communication http://www.siemens.com/simatic-net
● to website: Information and Download Center http://www.siemens.com/automation/net/catalog
● to website: Image database http://automation.siemens.com/bilddb
● to website: CAx Download Manager http://www.siemens.com/cax
● to website: Industry Online Support http://support.automation.siemens.com
Security information
Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4)
last modified: 23.10.2014
Date
31.10.2014
Changes preserved
© Copyright Siemens AG 2014