                      SIMATIC S7-1200, DIGITAL I/O SM 1223, 8DI / 8DO, 8DI DC 24 V, SINK/SOURCE, 8DO, TRANSISTOR 0.5A | 
                    
                    
                      | Supply voltage | 
                    
                    
                      | 24 V DC | 
                      Yes | 
                    
                    
                      | permissible range, lower limit (DC) | 
                      20.4 V | 
                    
                    
                      | permissible range, upper limit (DC) | 
                      28.8 V | 
                    
                    
                      | Input current | 
                    
                    
                      | from backplane bus 5 V DC, max. | 
                      145 mA | 
                    
                    
                      | Digital inputs | 
                    
                    
                      | ● from load voltage L+ (without load), max. | 
                      4 mA; per channel | 
                    
                    
                      | Output voltage | 
                    
                    
                      | Power supply to the transmitters | 
                    
                    
                      | ● present | 
                      Yes | 
                    
                    
                      | Power losses | 
                    
                    
                      | Power loss, typ. | 
                      2.5 W | 
                    
                    
                      | Digital inputs | 
                    
                    
                      | Number of digital inputs | 
                      8 | 
                    
                    
                      | ● In groups of | 
                      2 | 
                    
                    
                      | Input characteristic curve in accordance with IEC 61131, type 1 | 
                      Yes | 
                    
                    
                      | Number of simultaneously controllable inputs | 
                    
                    
                      | all mounting positions | 
                    
                    
                      | — up to 40 °C, max. | 
                      8 | 
                    
                    
                      | horizontal installation | 
                    
                    
                      | — up to 40 °C, max. | 
                      8 | 
                    
                    
                      | — up to 50 °C, max. | 
                      8 | 
                    
                    
                      | vertical installation | 
                    
                    
                      | — up to 40 °C, max. | 
                      8 | 
                    
                    
                      | Input voltage | 
                    
                    
                      | ● Type of input voltage | 
                      DC | 
                    
                    
                      | ● Rated value (DC) | 
                      24 V | 
                    
                    
                      | ● for signal "0" | 
                      5 V DC at 1 mA | 
                    
                    
                      | ● for signal "1" | 
                      15 VDC at 2.5 mA | 
                    
                    
                      | Input current | 
                    
                    
                      | ● for signal "0", max. (permissible quiescent current) | 
                      1 mA | 
                    
                    
                      | ● for signal "1", min. | 
                      2.5 mA | 
                    
                    
                      | ● for signal "1", typ. | 
                      4 mA; Typical | 
                    
                    
                      | Input delay (for rated value of input voltage) | 
                    
                    
                      | for standard inputs | 
                    
                    
                      | — Parameterizable | 
                      Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | 
                    
                    
                      | for interrupt inputs | 
                    
                    
                      | — Parameterizable | 
                      Yes | 
                    
                    
                      | Cable length | 
                    
                    
                      | ● Cable length, shielded, max. | 
                      500 m | 
                    
                    
                      | ● Cable length unshielded, max. | 
                      300 m | 
                    
                    
                      | Digital outputs | 
                    
                    
                      | Number of digital outputs | 
                      8 | 
                    
                    
                      | ● In groups of | 
                      1 | 
                    
                    
                      | short-circuit protection | 
                      No; to be provided externally | 
                    
                    
                      | Limitation of inductive shutdown voltage to | 
                      L+ (-48 V) | 
                    
                    
                      | Switching capacity of the outputs | 
                    
                    
                      | ● with resistive load, max. | 
                      0.5 A | 
                    
                    
                      | ● on lamp load, max. | 
                      5 W | 
                    
                    
                      | Output voltage | 
                    
                    
                      | ● Rated value (DC) | 
                      24 V | 
                    
                    
                      | ● for signal "0", max. | 
                      0.1 V; with 10 kOhm load | 
                    
                    
                      | ● for signal "1", min. | 
                      20 V DC | 
                    
                    
                      | Output current | 
                    
                    
                      | ● for signal "1" rated value | 
                      0.5 A | 
                    
                    
                      | ● for signal "1" permissible range, max. | 
                      0.5 A | 
                    
                    
                      | ● for signal "0" residual current, max. | 
                      10 µA | 
                    
                    
                      | Output delay with resistive load | 
                    
                    
                      | ● "0" to "1", max. | 
                      50 µs | 
                    
                    
                      | ● "1" to "0", max. | 
                      200 µs | 
                    
                    
                      | Aggregate current of outputs (per group) | 
                    
                    
                      | horizontal installation | 
                    
                    
                      | — up to 50 °C, max. | 
                      4 A; Current per mass | 
                    
                    
                      | Relay outputs | 
                    
                    
                      | Switching capacity of contacts | 
                    
                    
                      | — with inductive load, max. | 
                      0.5 A | 
                    
                    
                      | — on lamp load, max. | 
                      5 W | 
                    
                    
                      | — with resistive load, max. | 
                      0.5 A | 
                    
                    
                      | Cable length | 
                    
                    
                      | ● Cable length, shielded, max. | 
                      500 m | 
                    
                    
                      | ● Cable length unshielded, max. | 
                      150 m | 
                    
                    
                      | Interrupts/diagnostics/status information | 
                    
                    
                      | Alarms | 
                    
                    
                      | ● Alarms | 
                      Yes | 
                    
                    
                      | ● Diagnostic alarm | 
                      Yes | 
                    
                    
                      | Diagnostic messages | 
                    
                    
                      | ● Diagnostic functions | 
                      Yes | 
                    
                    
                      | ● Monitoring the supply voltage | 
                      Yes | 
                    
                    
                      | Diagnostics indication LED | 
                    
                    
                      | ● for status of the inputs | 
                      Yes | 
                    
                    
                      | ● For status of the outputs | 
                      Yes | 
                    
                    
                      | ● for maintenance | 
                      Yes | 
                    
                    
                      | ● Status indicator digital output (green) | 
                      Yes | 
                    
                    
                      | ● Status indicator digital input (green) | 
                      Yes | 
                    
                    
                      | Galvanic isolation | 
                    
                    
                      | Galvanic isolation digital inputs | 
                    
                    
                      | ● between the channels, in groups of | 
                      2 | 
                    
                    
                      | Galvanic isolation digital outputs | 
                    
                    
                      | ● between the channels, in groups of | 
                      1 | 
                    
                    
                      | ● between the channels and the backplane bus | 
                      500 V AC | 
                    
                    
                      | Degree and class of protection | 
                    
                    
                      | Degree of protection to EN 60529 | 
                      
                     | 
                    
                      | ● IP20 | 
                      Yes | 
                    
                    
                      | Standards, approvals, certificates | 
                    
                    
                      | CE mark | 
                      Yes | 
                    
                    
                      | CSA approval | 
                      Yes | 
                    
                    
                      | UL approval | 
                      Yes | 
                    
                    
                      | cULus | 
                      Yes | 
                    
                    
                      | RCM (formerly C-TICK) | 
                      Yes | 
                    
                    
                      | FM approval | 
                      Yes | 
                    
                    
                      | Marine approval | 
                    
                    
                      | ● Marine approval | 
                      Yes | 
                    
                    
                      | Climatic and mechanical conditions for storage and transport | 
                    
                    
                      | Climatic conditions for storage and transport | 
                    
                    
                      | Free fall | 
                    
                    
                      | — Drop height, max. (in packaging) | 
                      0.3 m; five times, in dispatch package | 
                    
                    
                      | Temperature | 
                    
                    
                      | — Permissible temperature range | 
                      -40 °C to +70 °C | 
                    
                    
                      | Air pressure acc. to IEC 60068-2-13 | 
                    
                    
                      | — Permissible air pressure | 
                      1080 to 660 hPa | 
                    
                    
                      | Relative humidity | 
                    
                    
                      | — Permissible range (without condensation) at 25 °C | 
                      95 % | 
                    
                    
                      | Mechanical and climatic conditions during operation | 
                    
                    
                      | Climatic conditions in operation | 
                    
                    
                      | Temperature | 
                    
                    
                      | — Permissible temperature range | 
                      -20 °C to +60 °C horizontal mounting, -20 °C to 50 °C vertical mounting, 95% humidity, non-condensing | 
                    
                    
                      | — Min. | 
                      -20 °C | 
                    
                    
                      | — max. | 
                      60 °C | 
                    
                    
                      | — Permissible temperature change | 
                      5°C to 55°C, 3°C / minute | 
                    
                    
                      | Connection method | 
                    
                    
                      | required front connector | 
                      Yes | 
                    
                    
                      | Mechanics/material | 
                    
                    
                      | Type of housing (front) | 
                      
                     | 
                    
                      | ● plastic | 
                      Yes | 
                    
                    
                      | Dimensions | 
                    
                    
                      | Width | 
                      45 mm | 
                    
                    
                      | Height | 
                      100 mm | 
                    
                    
                      | Depth | 
                      75 mm | 
                    
                    
                      | Weights | 
                    
                    
                      | Weight, approx. | 
                      210 g | 
                    
                    
                      | last modified: | 
                      14.10.2014 |