| Product type designation |
CP 443-5 Basic |
|
SIMATIC NET, CP 443-5 BASIC COMMUNICATIONS PROCESSOR FOR CONNECTING SIMATIC S7-400 TO PROFIBUS, FMS, S5-COMPATIBLE PG/OP AND S7 COMMUNICATION |
| Transmission rate |
| Transfer rate |
|
| ● at the 1st interface / acc. to PROFIBUS |
9.6 kbit/s ... 12 Mbit/s |
| Interfaces |
| Number of interfaces / acc. to Industrial Ethernet |
0 |
| Number of electrical connections |
|
| ● at the 1st interface / acc. to PROFIBUS |
1 |
| Design of the electrical connection |
|
| ● at the 1st interface / acc. to PROFIBUS |
9-pin Sub-D socket (RS485) |
| Supply voltage, current consumption, power loss |
| Type of voltage / of the supply voltage |
DC |
| Supply voltage / 1 / from backplane bus |
5 V |
| Supply voltage |
5 V |
| Relative symmetrical tolerance / for DC |
|
| ● at 5 V |
5 % |
| Active power loss |
6.5 W |
| Permitted ambient conditions |
| Ambient temperature |
|
| ● during operation |
0 ... 60 °C |
| ● during storage |
-40 ... +70 °C |
| ● during transport |
-40 ... +70 °C |
| Relative humidity / at 25 °C / without condensation / during operation / maximum |
95 % |
| Protection class IP |
IP20 |
| Design, dimensions and weight |
| Module format |
Compact module S7-400 single width |
| Width |
25 mm |
| Height |
290 mm |
| Depth |
210 mm |
| Net weight |
0.7 kg |
| Product properties, functions, components / general |
| Number of units |
|
| ● per CPU / maximum |
14 |
| ● Note |
depending on CPU type |
| Performance data |
| Performance data / open communication |
| Number of possible connections / for open communication / by means of SEND/RECEIVE blocks |
|
| ● maximum |
32 |
| Amount of data |
|
| ● as user data per connection / for open communication / by means of SEND/RECEIVE blocks / maximum |
240 byte |
| Performance data / FMS functions |
| Number of possible connections / for FMS connection / maximum |
48 |
| Amount of data / of the variables |
|
| ● for READ job / maximum |
237 byte |
| ● for WRITE job / maximum |
233 byte |
| Number of variables |
|
| ● Configurable from server to FMS partner |
512 |
| ● Loadable from server to FMS partner |
2640 |
| Performance data / S7 communication |
| Number of possible connections / for S7 communication |
|
| ● maximum |
48 |
| Performance data / multi-protocol mode |
| Number of possible connections / of which 2 reserved for PG/OP communication / with multi-protocol mode / maximum |
59 |
| Performance data / telecontrol |
| Protocol / is supported |
|
| ● TCP/IP |
No |
| Product functions / management, configuration |
| Configuration software |
|
| ● required |
STEP 7 V5.1 SP1 or higher and NCM S7 for PROFIBUS |
| Further Information / Internet Links |
| Internet-Link |
|
| ● to website: Selector SIMATIC NET SELECTION TOOL |
http://www.siemens.com/snst |
| ● to website: Industrial communication |
http://www.siemens.com/simatic-net |
| ● to website: Information and Download Center |
http://www.siemens.com/automation/net/catalog |
| ● to website: Image database |
http://automation.siemens.com/bilddb |
| ● to website: CAx Download Manager |
http://www.siemens.com/cax |
| ● to website: Industry Online Support |
http://support.automation.siemens.com |
| last modified: |
03.11.2014 |
Date 07.11.2014 |