Product type designation |
SCALANCE W746-1 |
Product description |
|
|
IWLAN ETHERNET CLIENT MODULE SCALANCE W746-1, FOR USE OUTSIDE OF USA 1 RADIO INTERFACE, IEEE 802.11B/G/A/H, INDUSTRIAL WIRELESS LAN (IWLAN), 2.4/5GHZ, UP TO 54 MBIT/S, 24VDC WPA2/802.11I/11E, UP TO 8 DEVICES, NAT/PAT, NOTE NATIONAL APPROVALS, POE, IP30 (-20-+60 DGR C) 2XEXT. ANTENNA CONNECTIONS SCOPE OF SUPPLY: MANUALS ON CD ROM GERMAN/ENGLISH 24VDC TERMINAL BLOCK |
Transmission rate |
Transfer rate |
|
● with WLAN / maximum |
54 Mbit/s |
● for Industrial Ethernet |
10 Mbit/s, 100 Mbit/s |
● Note |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Interfaces |
Number of electrical connections |
|
● for network components or terminal equipment |
1 |
● for power supply |
1 |
● for redundant voltage supply |
1 |
Design of the electrical connection |
|
● for network components or terminal equipment |
RJ45 socket |
● for power supply |
4-pole screw terminal, PoE |
design of the removable storage |
|
● C-PLUG |
Yes |
● KEY-PLUG |
No |
Interfaces / wireless |
Number of radio cards / permanently installed |
1 |
Number of electrical connections / for external antenna(s) |
2 |
Design of the electrical connection / for external antenna(s) |
R-SMA (socket) |
Product property / external antenna can be mounted directly on device |
Yes |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage |
DC |
Supply voltage / 1 |
|
● from terminal block |
24 V |
Supply voltage / 2 |
|
● from terminal block |
48 V |
Supply voltage |
|
● from Power-over-Ethernet acc. to IEEE802.3at for type 1 and IEEE802.3af |
48 V |
Consumed current |
|
● for DC / at 24 V / typical |
0.23 A |
● for DC / at 48 V / typical |
0.12 A |
● with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af / typical |
0.12 A |
Active power loss |
|
● for DC / at 24 V / typical |
6 W |
● for DC / at 48 V / typical |
6 W |
● with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af / typical |
6 W |
Permitted ambient conditions |
Ambient temperature |
|
● during operation |
-20 ... +60 °C |
● during storage |
-40 ... +70 °C |
● during transport |
-40 ... +70 °C |
Relative humidity / at 25 °C / without condensation / during operation / maximum |
90 % |
Ambient condition / for operation |
When used under hazardous conditions (Zone 2), the SCALANCE W784-x/xRR or W74x-1 product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529. |
Protection class IP |
IP30 |
Design, dimensions and weight |
Width / of the enclosure / without antenna |
100 mm |
Height / of the enclosure / without antenna |
205 mm |
Depth / of the enclosure / without antenna |
20 mm |
Net weight |
0.29 kg |
Mounting type |
For mounting on 35 mm DIN and S7-300 mounting rail, an additional adapter plate is required |
● S7-1500 rail mounting |
No |
● wall mounting |
Yes |
Wireless frequencies |
Radio frequency |
|
● for WLAN in 2.4 GHz frequency band |
2.41 ... 2.48 GHz |
● for WLAN in 5 GHz frequency band |
4.9 ... 5.8 GHz |
Product properties, functions, components / general |
Product function / Access Point Mode |
No |
Product function / Client Mode |
Yes |
Product function |
|
● Dual Client |
No |
● iHOP |
No |
● iPCF client |
No |
● iPCF-MC client |
No |
Number of iPCF-capable radio modules |
0 |
Product functions / management, configuration |
Number of manageable IP addresses / in client |
8 |
Product function |
|
● CLI |
Yes |
● web-based management |
Yes |
● MIB support |
Yes |
● TRAPs via email |
Yes |
● Configuration with STEP 7 |
Yes |
● configuration with STEP 7 in the TIA Portal |
Yes |
● operation with IWLAN controller |
No |
● operation with Enterasys WLAN controller |
No |
● iQoS |
No |
● forced roaming with IWLAN |
No |
● WDS |
No |
Protocol / is supported |
|
● Address Resolution Protocol (ARP) |
Yes |
● ICMP |
Yes |
● Telnet |
Yes |
● HTTP |
Yes |
● HTTPS |
Yes |
● TFTP |
Yes |
● DCP |
Yes |
● LLDP |
Yes |
Identification & maintenance function |
|
● I&M0 - device-specific information |
Yes |
● I&M1 – higher-level designation/location designation |
Yes |
Product functions / Diagnosis |
Product function |
|
● PROFINET IO diagnosis |
Yes |
● Link Check |
No |
● connection monitoring IP-Alive |
No |
● localization via Aeroscout |
No |
● SysLog |
Yes |
Protocol / is supported |
|
● SNMP v1 |
Yes |
● SNMP v2 |
Yes |
● SNMP v3 |
Yes |
Product functions / VLAN |
Product function |
|
● function VLAN with IWLAN |
No |
Product functions / DHCP |
Product function |
|
● DHCP client |
Yes |
● in Client Mode / DHCP server via LAN |
Yes |
Product functions / Security |
Product function |
|
● ACL - MAC-based |
No |
● Management security, ACL-IP based |
No |
● IEEE 802.1x (radius) |
Yes |
● NAT/NAPT |
Yes |
● access protection according to IEEE802.11i |
Yes |
● WPA/WPA2 |
Yes |
● TKIP/AES |
Yes |
Protocol / is supported |
|
● SSH |
Yes |
Product functions / Time |
Protocol / is supported |
|
● SNTP |
Yes |
● SIMATIC Time |
No |
Standards, specifications, approvals |
Standard |
|
● for FM |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
● for hazardous zone |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X (only approved in combination with an enclosure with degree of protection of at least IP 54) |
● for safety / from CSA and UL |
UL 60950-1 CSA C22.2 No. 60950-1 |
● for hazardous zone / from CSA and UL |
ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 (only approved in combination with an enclosure with degree of protection of at least IP 54) |
Certificate of suitability |
|
● EC declaration of conformity |
Yes |
● CE marking |
Yes |
● C-Tick |
Yes |
● E1 approval |
Yes |
● Railway application in accordance with EN 50155 |
Yes |
● NEMA4X |
No |
● Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af |
Yes |
Standard for wireless communication |
|
● IEEE 802.11a |
Yes |
● IEEE 802.11b |
Yes |
● IEEE 802.11e |
Yes |
● IEEE 802.11g |
Yes |
● IEEE 802.11h |
Yes |
● IEEE 802.11i |
Yes |
● IEEE 802.11n |
No |
Wireless approval |
You will find the current list of countries at: www.siemens.de/funkzulassungen |
Marine classification association |
|
● American Bureau of Shipping Europe Ltd. (ABS) |
No |
● Bureau Veritas (BV) |
No |
● Det Norske Veritas (DNV) |
No |
● Germanische Lloyd (GL) |
No |
● Lloyds Register of Shipping (LRS) |
No |
● Nippon Kaiji Kyokai (NK) |
No |
● Polski Rejestr Statkow (PRS) |
No |
Accessories |
accessories |
24 V DC screw terminal included in scope of delivery |
Further Information / Internet Links |
Internet-Link |
|
● to website: TIA Selection Tool |
http://www.siemens.com/tia-selection-tool |
● to the website: IWLAN |
http://www.siemens.com/iwlan |
● to website: Industry Mall |
https://mall.industry.siemens.com |
● to website: Information and Download Center |
http://www.siemens.com/automation/net/catalog |
● to website: Image database |
http://automation.siemens.com/bilddb |
● to website: CAx Download Manager |
http://www.siemens.com/cax |
● to website: Industry Online Support |
http://support.automation.siemens.com |
Security information |
Security information |
Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4) |
last modified: |
04.11.2014 |
Date 05.11.2014 |
Changes preserved © Copyright Siemens AG 2014 |