6GK5206-1BC00-2AF2 SCALANCE XF206-1

Product Code: 6GK5206-1BC00-2AF2

Availability: In Stock

Price: $417.85
Artikelnummer 6GK5206-1BC00-2AF2
Product type designation SCALANCE XF206-1
Product description
SCALANCE XF206-1, FLAT, MANAGED IE SWITCH, 6 X 10/100MBIT/S RJ45 PORTS, 1 X 100MBIT/S FO PORT, FAULT SIGNAL CONTACT WITH SET- BUTTON, REDUNDANT POWER SUPPLY, PROFINET-IO DEVICE, NETWORKMANAGEMENT, RED.- MANAGER INTEGRATED, INCL. MANUAL ON CD, C-PLUG OPTIONAL
Transmission rate
Transfer rate 10 Mbit/s, 100 Mbit/s
Interfaces
Number of electrical/optical connections
● for network components or terminal equipment / maximum 7
Number of electrical connections
● for network components or terminal equipment 6
● for signaling contact 1
● for power supply 1
● for redundant voltage supply 1
Design of the electrical connection
● for network components or terminal equipment RJ45 port
● for signaling contact 2-pole terminal block
● for power supply 4-pole terminal block
Number of optical interfaces
● for fiber optic cable / at 100 Mbit/s 1
Design of the optical interface
● for fiber optic cable / at 100 Mbit/s BFOC sockets (multimode up to 5 km)
Connectable optical power relative to 1 mW
● of the transmitter output / minimum -19 dB
● of the transmitter output / maximum -14 dB
Damping ratio / of the FOC transmission link / minimum necessary 0 dB
Range / at the optical interface / depending on the optical fiber used 0 ... 5 km
design of the removable storage / C-PLUG Yes
Signal-Inputs/outputs
Operating voltage / of the signaling contacts
● for DC / Rated value 24 V
Operating current / of the signaling contacts
● for DC / maximum 0.1 A
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltage DC
Supply voltage
● external 24 V
● external 18 ... 32 V
Product component / fusing at power supply input Yes
Fuse protection type / at input for supply voltage 1,1 A / 33 V
Consumed current / maximum 0.17 A
Active power loss
● for DC / at 24 V 4.08 W
Permitted ambient conditions
Ambient temperature
● during operation -40 ... +60 °C
● during storage -40 ... +70 °C
● during transport -40 ... +70 °C
● Note If the IE switch XF 200 is installed horizontally a maximum ambient temperature of +40 °C is permitted
Relative humidity
● at 25 °C / without condensation / during operation / maximum 95 %
Protection class IP IP20
Design, dimensions and weight
Design Flat
Width 75 mm
Height 125 mm
Depth 73 mm
Net weight 0.25 kg
Mounting type
● 35 mm DIN rail mounting Yes
● wall mounting No
● S7-300 rail mounting No
● S7-1500 rail mounting No
Product properties, functions, components / general
Cascading in cases of star topology Any (depending only on signal propagation time)
Product functions / management, configuration
Product function
● CLI Yes
● web-based management Yes
● MIB support Yes
● TRAPs via email Yes
● Configuration with STEP 7 Yes
● Port mirroring Yes
● multiport mirroring No
● with IRT / PROFINET IO switch No
● PROFINET IO diagnosis Yes
● switch-managed Yes
Protocol / is supported
● Telnet Yes
● HTTP Yes
● HTTPS Yes
● TFTP Yes
● FTP Yes
● BOOTP No
● DCP Yes
● LLDP Yes
Identification & maintenance function
● I&M0 - device-specific information Yes
● I&M1 – higher-level designation/location designation Yes
Protocol / is supported
● SNMP v1 Yes
● SNMP v2 Yes
● SNMP v3 Yes
Product functions / Diagnosis
Product function
● Port diagnostics Yes
● Statistics Packet Size Yes
● Statistics packet type Yes
● Error statistics Yes
Product functions / DHCP
Product function
● DHCP client Yes
Product functions / Redundancy
Product function
● Ring redundancy Yes
● High Speed Redundancy Protocol (HRP) Yes
● high speed redundancy protocol (HRP) with redundancy manager Yes
● high speed redundancy protocol (HRP) with standby redundancy No
● Media Redundancy Protocol (MRP) Yes
● media redundancy protocol (MRP) with redundancy manager Yes
● Passive listening Yes
Product functions / Security
Protocol / is supported
● SSH Yes
Product functions / Time
Product function
● SICLOCK support Yes
Protocol / is supported
● NTP No
● SNTP Yes
Standards, specifications, approvals
Standard
● for FM FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4
● for hazardous zone EN 60079-0: 2006, EN60079-15: 2005, II 3 (2) G Ex nA [op is] IIC T4, KEMA 07 ATEX 0145 X
● for safety / from CSA and UL UL 60950-1, CSA C22.2 No. 60950-1
● for hazardous zone / from CSA and UL ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4
● for emitted interference EN 61000-6-4:2001 (Class A)
● for interference immunity EN 61000-6-2:2001
Certificate of suitability EN 61000-6-2:2001, EN 61000-6-4:2001
● CE marking Yes
● C-Tick Yes
● KC approval Yes
● Railway application in accordance with EN 50155 No
● Railway application in accordance with EN 50124-1 No
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS) No
● Bureau Veritas (BV) No
● Det Norske Veritas (DNV) No
● Germanische Lloyd (GL) No
● Lloyds Register of Shipping (LRS) No
● Nippon Kaiji Kyokai (NK) No
● Polski Rejestr Statkow (PRS) No
MTBF / at 40 °C 43.52 y
Further Information / Internet Links
Internet-Link
● to website: Selector SIMATIC NET SELECTION TOOL http://www.siemens.com/snst
● to website: Industrial communication http://www.siemens.com/simatic-net
● to website: Information and Download Center http://www.siemens.com/automation/net/catalog
● to website: Image database http://automation.siemens.com/bilddb
● to website: CAx Download Manager http://www.siemens.com/cax
● to website: Industry Online Support http://support.automation.siemens.com
Security information
Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4)
last modified: 04.11.2014
Date
04.11.2014
Changes preserved
© Copyright Siemens AG 2014

Write a review

Note: HTML is not translated!

Rating: Bad Good

Enter the code in the box below: