6ES7673-2CC40-0YA0 SIMATIC WINAC SLOT 412 V4.0

Product Code: 6ES7673-2CC40-0YA0

Availability: In Stock

Price: $2,011.85
  
 

SIMATIC WINAC SLOT 412 V4.0, PC BOARD + SW, SINGLE LICENSE F. 1 INSTALL., INCL R-SW, SW AND DOCU. ON CD, CLASS A, 3 LANGUAGES (G,E,F), EXECUTABLE U. WIN 2000/XP PRO, REFERENCE-HW: SIMATIC PC
General information
Hardware product version 01
Firmware version V4.0
Supply voltage
24 V DC Yes; Safety extra low voltage SELV
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
permissible range (ripple included), lower limit (DC) 18.5 V
permissible range (ripple included), upper limit (DC) 30.2 V
Input current
from external supply (24 V DC), max. 1 A
from PCI interface (DC 5 V), max. 0.8 A
from PCI interface (DC 12 V), max. 0.4 A
Power
with external supply , max. 19 W
with supply from the PC, max. 10 W
Power losses
Power loss, max. 11 W
Memory
Work memory
integrated 384 kbyte
integrated (for program) 192 kbyte
integrated (for data) 192 kbyte
Load memory
expandable FEPROM Yes; with Memory Card (FLASH)
expandable FEPROM, max. 64 Mbyte
integrated RAM, max. 256 kbyte
expandable RAM Yes; with Memory Card (FLASH)
expandable RAM, max. 64 Mbyte
Battery
Backup battery
Backup battery
Voltage 3.6 V; Lithium
Backup current, typ. 500 µA
Backup current, max. 1300 µA
Backup time, min. 1110 h
Backup time, typ. 2900 h
CPU processing times
for bit operations, typ. 0.1 µs
for fixed point arithmetic, typ. 0.1 µs
for floating point arithmetic, typ. 0.3 µs
CPU-blocks
DB
Number, max. 511
Size, max. 64 kbyte
FB
Number, max. 256
Size, max. 64 kbyte
FC
Number, max. 256
Size, max. 64 kbyte
OB
Size, max. 64 kbyte
Number of time alarm OBs 2
Number of delay alarm OBs 2
Number of time interrupt OBs 2
Number of process alarm OBs 2
Nesting depth
per priority class 24
additional within an error OB 1
Counters, timers and their retentivity
S7 counter
Number 2048
Retentivity
adjustable Yes
lower limit 0
upper limit 2047
preset Z 0 to Z 7
Counting range
adjustable Yes
lower limit 1
upper limit 999
IEC counter
present Yes
Type SFB
S7 times
Number 2048
Retentivity
lower limit 0
upper limit 2047
preset No times retentive
Time range
lower limit 10 ms
upper limit 9990 s
IEC timer
present Yes
Type SFB
Data areas and their retentivity
Retentivity without UPS and PS Extension Board none
Retentivity with UPS none
Retentivity with PS extension board and battery total working and load memory
Flag
Number, max. 4 kbyte
of which retentive From MB 0 to MB 4095
Retentivity preset MB 0 to MB 15
Number of clock memories 8
Address area
I/O address area
Inputs 4 kbyte
Outputs 4 kbyte
of which, distributed
MPI/DP interface, inputs 2 kbyte
MPI/DP interface, outputs 2 kbyte
DP interface, inputs 4 kbyte; for each line that is operated in isochronous mode, i.e. to which an OB61 to 62 has been assigned, the distributed IO address areas are halved
DP interface, outputs 4 kbyte; for each line that is operated in isochronous mode, i.e. to which an OB61 to 62 has been assigned, the distributed IO address areas are halved
Process image
Inputs, adjustable 4 kbyte
Outputs, adjustable 4 kbyte
Inputs, default 128 byte
Outputs, default 128 byte
Subprocess images
Number of subprocess images, max. 15
Digital channels
Inputs 32000
Outputs 32000
Analog channels
Inputs 2000
Outputs 2000
Hardware configuration
Number of DP masters
overall 2
integrated 2
Number of operable FMs and CPs (recommended)
FM FM distributed: FM 350-1 / 350-2, FM 351, FM 352, FM 353, FM 355 / 355-2
CP, point-to-point CP 340, CP 341 distributed
CP, LAN Over PC CP
Slots
Required slots 1; PCI, PCI format: 3/4
Time of day
Clock
Hardware clock (real-time clock) Yes
battery-backed and synchronizable Yes
Operating hours counter
Number 8
Clock synchronization
supported Yes
to PC-CP, slave Yes
to MPI, master Yes
to MPI, slave Yes
1st interface
Interface type RS 485 / PROFIBUS
Physics RS 485
Isolated Yes
Functionality
MPI Yes
DP master Yes
DP slave Yes
MPI
Number of connections 16
Transmission rate, max. 12 Mbit/s
Services
PG/OP communication Yes
Routing Yes
Global data communication Yes
S7 basic communication Yes
S7 communication Yes
DP master
Number of connections, max. 16
Transmission rate, max. 12 Mbit/s
Number of DP slaves, max. 32
Services
PG/OP communication Yes
Routing Yes
Global data communication No
S7 basic communication Yes
S7 communication Yes
Equidistance mode support Yes
SYNC/FREEZE Yes
Activation/deactivation of DP slaves Yes
Direct data exchange (slave-to-slave communication) Yes
DPV0 Yes
DPV1 Yes
Address area
Inputs, max. 2 kbyte
Outputs, max. 2 kbyte
User data per DP slave
Inputs, max. 244 byte
Outputs, max. 244 byte
DP slave
Services
Routing Yes
2nd interface
Interface type RS 485 / PROFIBUS
Physics RS 485
Isolated Yes
Functionality
MPI No
DP master Yes
DP slave Yes
DP master
Number of connections, max. 16
Transmission rate, max. 12 Mbit/s
Number of DP slaves, max. 64
Services
PG/OP communication Yes
Routing Yes
Global data communication No
S7 basic communication Yes
S7 communication Yes
Equidistance mode support Yes
SYNC/FREEZE Yes
Activation/deactivation of DP slaves Yes
Direct data exchange (slave-to-slave communication) Yes
DPV0 Yes
DPV1 Yes
Address area
Inputs, max. 4 kbyte
Outputs, max. 4 kbyte
User data per DP slave
Inputs, max. 244 byte
Outputs, max. 244 byte
DP slave
Services
PG/OP communication Yes
Routing Yes
Isochronous mode
Isochronous operation (application synchronized up to terminal) Yes
Number of DP masters with isochronous mode 2
User data per isochronous slave, max. 244 byte
equidistance Yes
shortest clock pulse 1.5 ms
Communication functions
PG/OP communication Yes
Global data communication
supported Yes
S7 basic communication
supported Yes
S7 communication
as server Yes
As client Yes
Number of connections
overall 16
usable for PG communication
reserved for PG communication 1
usable for OP communication
reserved for OP communication 1
S7 message functions
Number of login stations for message functions, max. 8
SCAN procedure Yes
Process diagnostic messages Yes; Alarm_S
Alarm 8-blocks Yes
Process control messages Yes
Test commissioning functions
Status block Yes
Single step Yes
Status/control
Status/control variable Yes
Forcing
Forcing Yes
Diagnostic buffer
present Yes
Number of entries, max.
preset 120
Hardware requirements
Hardware required PC with color monitor, keyboard, mouse or pointing device for Windows
Main memory, min. 256 Mbyte
Required memory on hard disk, min. 60 Mbyte
Processor Intel Pentium 800 MHz
Multi-processor system Yes
Hyper-threading Yes
Operating systems
Windows NT 4.0 No
Windows 2000 Yes; Professional, SP3 or higher
Windows XP Yes; Professional, SP1 and SP2
Configuration
Configuration software
STEP 7 Yes; V5.3 SP2 or higher
programming
Nesting levels 7
Programming language
LAD Yes
FBD Yes
STL Yes
SCL Yes
CFC Yes
GRAPH Yes
HiGraph® Yes
Software libraries
Easy Motion Control Yes
Know-how protection
User program protection/password protection Yes
Open Development interfaces
CCX (Custom Code Extension) No
CMI (Controller Management Interface) Yes; With WinAC ODK V4.1
SMX (Shared Memory Extension) Yes; With WinAC ODK V4.1
Inputs 4 kbyte
Outputs 4 kbyte
Dimensions
Width 98 mm
Height 288 mm
Weights
Weight, approx. 300 g
Status Jun 16, 2014

Write a review

Note: HTML is not translated!

Rating: Bad Good

Enter the code in the box below: