6ES7671-1RC07-0YA0 SIMATIC WINAC RTX F 2009

Product Code: 6ES7671-1RC07-0YA0

Availability: In Stock

Price: $1,541.25
Artikelnummer 6ES7671-1RC07-0YA0
SIMATIC WINAC RTX F 2009, SINGLE LICENSE F. 1 INSTALL., R-SW, SW AND DOCU. ON DVD, LICENSE KEY ON USB STICK, CLASS A, 3 LANGUAGES (D,E), EXECUTABLE UNDER WINDOWS XP SP2, SP3 AND INTERVALZERO RTX, REFERENCE-HW: SIMATIC PC
General information
Hardware product version -
Firmware version 4,5
Engineering with
● Programming package STEP7 V5.4 SP5 or higher + HSP135 as basic requirement for the HSP178 for WinAC RTX F 2009 on Embedded Controller + HSP179 for WinAC RTX F 2009 on PC station / iMap V3.0 SP1 / option package S7 Distributed Safety V5.4 SP5 or higher
Memory
Work memory
● integrated (for program) 4 Mbyte; Adjustable; depends on Non Paged Memory Pool
● integrated (for data) 4 Mbyte; Adjustable; depends on Non Paged Memory Pool
Load memory
● integrated RAM, max. 8 Mbyte; Adjustable; depends on Non Paged Memory Pool
CPU processing times
for bit operations, typ. 0.004 µs; Typical
for fixed point arithmetic, typ. 0.003 µs; Typical
for floating point arithmetic, typ. 0.004 µs; Typical
Reference platform Pentium 4, 2.4 GHz
CPU-blocks
DB
● Number, max. 65 535; Limited only by RAM set for data
● Size, max. 64 kbyte
FB
● Number, max. 65 536; Limited only by RAM set for code
● Size, max. 64 kbyte
FC
● Number, max. 65 536; Limited only by RAM set for code
● Size, max. 64 kbyte
OB
● Number, max. Limited only by RAM for code
● Size, max. 64 kbyte
● Number of free cycle OBs 1; OB 1
● Number of time alarm OBs 1; OB 10
● Number of delay alarm OBs 1; OB 20
● Number of time interrupt OBs 9; OB 30-38
● Number of process alarm OBs 1; OB 40
● Number of ODK OBs 3; OB 52-54
● Number of DPV1 alarm OBs 3; OB 55-57
● Number isochronous mode OBs 2; OB 61-62
● Number of startup OBs 2; OB 100, 102
● Number of asynchronous error OBs 7; OB 80, 82-85, 86, 88
● Number of synchronous error OBs 2; OB 121, 122
Nesting depth
● per priority class 24
● additional within an error OB 24
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2047
— preset 8
Counting range
— can be set Yes
— lower limit 0
— upper limit 999
IEC counter
● present Yes
● Type SFB
S7 times
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2 047
— preset 0
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
● Type SFB
Data areas and their retentivity
Retentivity without UPS and PS Extension Board 128 KB with SIMATIC IPC427C and HMI IPC477C; further SIMATIC PCs on request
Retentivity with UPS all data
Flag
● Number, max. 16 kbyte
● of which retentive MB 0 to MB 16383
● Retentivity preset MB 0 to MB 15
● Number of clock memories 8
Local data
● adjustable, max. 32 kbyte
● preset 16 kbyte
● per priority class, max. 32 kbyte
Address area
I/O address area
● Inputs 16 kbyte
● Outputs 16 kbyte
of which, distributed
— DP interface, inputs 16 kbyte
— DP interface, outputs 16 kbyte
— PN interface, inputs 16 kbyte
— PN interface, outputs 16 kbyte
Process image
● Inputs, adjustable 8 kbyte
● Outputs, adjustable 8 kbyte
● Inputs, default 512 byte
● Outputs, default 512 byte
Subprocess images
● Number of subprocess images, max. 15
Digital channels
● Inputs 128 000
● Outputs 128 000
Analog channels
● Inputs 8 000
● Outputs 8 000
Hardware configuration
Submodules
● Number of submodules, max 4
● of which PROFIBUS, max. 4; Supported interfaces: see 1st and 2nd interface
● of which Industrial Ethernet, max. 1; Supported interfaces: see 3rd and 4th interface
Number of operable FMs and CPs (recommended)
● FM 4; FM distributed: FM 350-1 / 350-2, FM 351, FM 352, FM 353, FM 355 / 355-2
● CP, point-to-point 2; CP 340, CP 341 distributed
● CP, LAN Over PC CP
Time of day
Clock
● Hardware clock (real-time clock) Yes
● battery-backed and synchronizable Yes
Operating hours counter
● Number 8
Clock synchronization
● supported Yes
● to PC-CP, slave Yes
● on Ethernet via NTP Yes
Interfaces
1st interface
Interface type CP 5611-A2, CP 5621, integrated PROFIBUS interface of the SIMATIC PC
Max. no. of simultaneously operable CPs 1
Physics RS 485 / PROFIBUS
Isolated Yes
Power supply to interface (15 to 30 V DC), max. does not exist
Functionality
● MPI No
● DP master Yes
● DP slave No
DP master
● Number of connections, max. 8
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 64
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— Equidistance mode support Yes; Only in conjunction with isochronous mode
— Isochronous mode Yes
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV0 Yes
— DPV1 Yes
Address area
— Inputs, max. 16 kbyte
— Outputs, max. 16 kbyte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
2nd interface
Interface type CP 5613, CP 5613-A2, CP 5603
Max. no. of simultaneously operable CPs 4
Physics RS 485 / PROFIBUS
Isolated Yes
Functionality
● MPI No
● DP master Yes
● DP slave No
DP master
● Number of connections, max. 50
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 125
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— Equidistance mode support Yes; Only in conjunction with isochronous mode
— Isochronous mode Yes
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV0 Yes
— DPV1 Yes
Address area
— Inputs, max. 16 kbyte
— Outputs, max. 16 kbyte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
3rd interface
Interface type PROFINET
Max. no. of simultaneously operable CPs 1; Intel Pro/1000 (Intel 82571EB, 82573L, 82574L, 82541PI; non shared IRQ required); integrated IE interface SIMATIC PC 4x7B, 6x7B, 8x7B and IPC4x7C
Physics Ethernet
Isolated Yes
Automatic detection of transmission speed Yes; 10/100 Mbit/s
Functionality
● PROFINET IO Controller Yes
● PROFINET IO Device No
● PROFINET CBA Yes
● Open IE communication Yes
● Web server No
PROFINET IO Controller
● Transmission rate, min. 100 Mbit/s
● Transmission rate, max. 100 Mbit/s
● Number of connectable IO devices, max. 128
● IRT, supported No
● Prioritized startup supported Yes
— Number of IO Devices, max. 32
● Activation/deactivation of IO Devices Yes
— Maximum number of IO devices that can be activated/deactivated at the same time. 8
● IO Devices changing during operation (partner ports), supported Yes
● Device replacement without swap medium Yes
● Send cycles 1 ms
● Updating time 1 - 512 ms (minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the volume of configured user data)
Services
— PG/OP communication Yes
— Routing Yes; S7 routing
— S7 communication Yes
— Open IE communication Yes
Address area
— Inputs, max. 16 kbyte
— Outputs, max. 16 kbyte
— User data per address area, max. 2 kbyte
— User data consistency, max. 256 byte
SIMATIC communication
● PG/OP communication Yes
● S7 routing Yes
● S7 communication Yes
● Number of connections, max. 16
Open IE communication
● Open IE communication, supported Yes
● Number of connections, max. 32
● Local port numbers used at the system end 0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
4th interface
Interface type PROFINET
Max. no. of simultaneously operable CPs 1; CP 1616 (HW release 8 or above), CP 1604 (HW release 7 or higher), integrated PROFINET interface of SIMATIC PC and S7-mEC
Physics Ethernet
Isolated Yes
Automatic detection of transmission speed Yes; 10/100 Mbit/s
Functionality
● PROFINET IO Controller Yes
● PROFINET CBA Yes
● Open IE communication Yes
● Web server No
PROFINET IO Controller
● Transmission rate, max. 100 Mbit/s
● Number of connectable IO devices, max. 256
● Number of IO devices with IRT and the option "high flexibility" 64
— of which in line, max. 32
● IRT, supported Yes
● Prioritized startup supported Yes
— Number of IO Devices, max. 32
● Activation/deactivation of IO Devices Yes
— Maximum number of IO devices that can be activated/deactivated at the same time. 8
● IO Devices changing during operation (partner ports), supported Yes
● Device replacement without swap medium Yes
● Send cycles 250 µs, 500 µs, 1 ms
● Updating time 0.25...512 depending on the send cycle
Services
— PG/OP communication Yes
— Routing Yes; S7 routing
— S7 communication Yes
— Open IE communication Yes
Address area
— Inputs, max. 16 byte; KB
— Outputs, max. 16 byte; KB
— User data per address area, max. 2 byte
— User data consistency, max. 256 byte; Byte
SIMATIC communication
● PG/OP communication Yes
● S7 routing Yes
● S7 communication Yes
● Number of connections, max. 32
Open IE communication
● Open IE communication, supported Yes
● Number of connections, max. 32
● Local port numbers used at the system end 0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535
Isochronous mode
Isochronous operation (application synchronized up to terminal) Yes; only PROFIBUS
Number of DP masters with isochronous mode 2
User data per isochronous slave, max. 128 byte
equidistance Yes
shortest clock pulse 2.2 ms; 2.2 ms without partial process image; 2.2 ms with partial process image
Communication functions
PG/OP communication Yes
Data record routing No
Global data communication
● supported No
S7 basic communication
● supported No
S7 communication
● supported Yes
● as server Yes
● As client Yes
● User data per job, max. 64 kbyte; Depends on which block is used: BSEND/USEND or PUT/GET
Open IE communication
● TCP/IP Yes
— Number of connections, max. Dependent on interface
— Data length, max. 64 KB - 2 bytes = 65534 bytes
● ISO-on-TCP (RFC1006) No
● UDP Yes
— Number of connections, max. Dependent on interface
— Data length, max. 1 472 byte
Web server
● supported No
PROFINET CBA (at set setpoint communication load)
● Setpoint for the CPU communication load 20 %
● Number of remote interconnection partners 64
● Number of functions, master/slave 30
● Total of all Master/Slave connections 1 000
● Data length of all incoming connections master/slave, max. 6 800 byte
● Data length of all outgoing connections master/slave, max. 6 800 byte
● Number of device-internal and PROFIBUS interconnections 500
● Data length of device-internal und PROFIBUS interconnections, max. 4 000 byte
● Data length per connection, max. 1 400 byte
Remote interconnections with acyclic transmission
— Sampling frequency: Sampling time, min. 500 ms
— Number of incoming interconnections 100
— Number of outgoing interconnections 100
— Data length of all incoming interconnections, max. 2 000 byte
— Data length of all outgoing interconnections, max. 2 000 byte
— Data length per connection, max. 1 400 byte
Remote interconnections with cyclic transmission
— Transmission frequency: Transmission interval, min. 10 ms
— Number of incoming interconnections 200
— Number of outgoing interconnections 200
— Data length of all incoming interconnections, max. 4 800 byte
— Data length of all outgoing interconnections, max. 4 800 byte
— Data length per connection, max. 250 byte
HMI variables via PROFINET (acyclic)
— Number of stations that can log on for HMI variables (PN OPC/iMap) 3
— HMI variable updating 500 ms
— Number of HMI variables 200
— Data length of all HMI variables, max. 2 000 byte
PROFIBUS proxy functionality
— supported Yes
— Number of linked PROFIBUS devices 16
— Data length per connection, max. 240 byte; Slave-dependent
Number of connections
● overall 64
● usable for PG communication
— reserved for PG communication 1
● usable for OP communication
— reserved for OP communication 1
S7 message functions
Number of login stations for message functions, max. 62
SCAN procedure No
Process diagnostic messages Yes; ALARM_S, ALARM_SQ, ALARM_D, ALARM_DQ
simultaneously active Alarm-S blocks, max. 20; of a total of 20 for all SFCs
Alarm 8-blocks Yes
● Number of instances for alarm 8 and S7 communication blocks, max. 600
Process control messages No
Test commissioning functions
Status block Yes
Single step Yes
Status/control
● Status/control variable Yes
Forcing
● Forcing No
Diagnostic buffer
● present Yes
● Number of entries, max.
— preset 120
Hardware requirements
Hardware required PC with color monitor, keyboard, mouse or pointing device for Windows
Main memory, min. 1 Gbyte
Required memory on hard disk, min. 100 Mbyte
Processor Intel Celeron M 900 MHz or compatible (older PC systems with Programmable Interrupt Controllers (PIC) are not suitable for WinAC RTX F 2009.)
● Multi-processor system No
● Hyper-threading Yes
Operating systems
Configuration
Configuration software
● STEP 7 Yes; V5.4 SP5 + HSP135 as basic requirement for the HSP178 for WinAC RTX F 2009 on Embedded Controller + HSP179 for WinAC RTX F 2009 on PC station, engineering tools (optional)
programming
● Nesting levels 8
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Software libraries
— Easy Motion Control Yes
— Software redundancy Yes; V1.2 and higher, only operation of WinAC RTX F with WinAC RTX
Number of simultaneously active SFCs
— DPSYC_FR 20; of a total of 20 for all SFCs
— D_ACT_DP 20; of a total of 20 for all SFCs
— RD_REC 20; of a total of 20 for all SFCs
— WR_REC 20; of a total of 20 for all SFCs
— WR_PARM 20; of a total of 20 for all SFCs
— PARM_MOD 20; of a total of 20 for all SFCs
— WR_DPARM 20; of a total of 20 for all SFCs
— DPNRM_DG 20; of a total of 20 for all SFCs
— RDSYSST 20; of a total of 20 for all SFCs
Number of simultaneously active SFBs
— RD_REC 20; of a total of 20 for all SFBs
— WR_REC 20; of a total of 20 for all SFBs
Know-how protection
● User program protection/password protection Yes
Open Development interfaces
● CCX (Custom Code Extension) Yes; WinAC ODK V4.2 or higher
● CMI (Controller Management Interface) Yes; WinAC ODK V4.2 or higher
● SMX (Shared Memory Extension) Yes; WinAC ODK V4.2 or higher
— Inputs 4 kbyte
— Outputs 4 kbyte
Weights
Weight, approx. 100 g; With packaging
last modified: 14.10.2014