SIMATIC S7-400, DIG.OUTPUT MOD. SM 422, OPTIC. ISOLATED, 32 DO, 24V DC, 0.5A WITH 0,15 MS OUTPUT DELAY, DIAGNOSTICS | 
| Supply voltage | 
| Load voltage L+ | 
| ● Rated value (DC) | 
24 V | 
| ● permissible range, lower limit (DC) | 
20.4 V | 
| ● permissible range, upper limit (DC) | 
28.8 V | 
| Load voltage L1 | 
| ● permissible range, lower limit (AC) | 
20.4 V | 
| ● permissible range, upper limit (AC) | 
28.8 V | 
| Input current | 
| from load voltage L+ (without load), max. | 
120 mA | 
| from backplane bus 5 V DC, max. | 
200 mA | 
| Power loss | 
| Power loss, max. | 
8 W | 
| Digital outputs | 
| Number of digital outputs | 
32 | 
| Limitation of inductive shutdown voltage to | 
L+ (-45 V) | 
| Switching capacity of the outputs | 
| ● Lamp load, max. | 
5 W | 
| Output voltage | 
| ● for signal "1", min. | 
L+ (-0.8 V) | 
| Output current | 
| ● for signal "1" rated value | 
0.5 A | 
| ● for signal "1" permissible range for 0 to 60 °C, min. | 
5 mA | 
| ● for signal "1" permissible range for 0 to 60 °C, max. | 
0.6 A | 
| ● for signal "0" residual current, max. | 
0.5 mA | 
| Switching frequency | 
| ● with resistive load, max. | 
100 Hz | 
| ● with inductive load, max. | 
2 Hz | 
| Total current of the outputs (per group) | 
| all mounting positions | 
| — up to 60 °C, max. | 
2 A | 
| Cable length | 
| ● Cable length, shielded, max. | 
1 000 m | 
| ● Cable length unshielded, max. | 
600 m | 
| Interrupts/diagnostics/status information | 
| Alarms | 
| ● Diagnostic alarm | 
Yes; Parameterizable | 
| Diagnostic messages | 
| ● Diagnostics | 
Yes; internal/ external fault | 
| Galvanic isolation | 
| Galvanic isolation digital outputs | 
| ● between the channels, in groups of | 
8 | 
| ● between the channels and the backplane bus | 
Yes | 
| Isolation | 
| Isolation tested with | 
500 V DC | 
| Dimensions | 
| Width | 
25 mm | 
| Height | 
290 mm | 
| Depth | 
210 mm | 
| Weights | 
| Weight, approx. | 
600 g | 
| last modified: | 