6ES7412-3HJ14-0AB0 CPU412-3H, 3 SS, 768 KB, F. S7-400H/F/FH

Product Code: 6ES7412-3HJ14-0AB0

Availability: In Stock

Price: $1,712.50
  
 
Artikelnummer 6ES7412-3HJ14-0AB0
SIMATIC S7-400H, CPU 412-3H CENTRAL UNIT FOR S7-400H AND S7-400F/FH, 3 INTERFACES: 1 MPI/DP AND 2 FOR SYNC MODULES 768 KB MEMORY (256 KB DATA/512 KB CODE)
General information
Hardware product version 1
Firmware version V4.5
Engineering with
● Programming package STEP7 V 5.3 SP2 or higher with HW update
CiR - Configuration in RUN
CiR synchronization time, basic load 150 ms
CiR synchronization time, time per I/O slave 40 µs
Supply voltage
24 V DC No; Power supply via system power supply
Input current
from backplane bus 5 V DC, typ. 1.2 A
from backplane bus 5 V DC, max. 1.5 A
from backplane bus 24 V DC, max. 150 mA; Per DP interface
from interface 5 V DC, max. 90 mA; At each DP interface
Power losses
Power loss, typ. 5.5 W
Memory
Type of memory other
Work memory
● Integrated 768 kbyte
● integrated (for program) 512 kbyte
● integrated (for data) 256 kbyte
● expandable No
Load memory
● expandable FEPROM Yes
● expandable FEPROM, max. 64 Mbyte
● integrated RAM, max. 256 kbyte
● expandable RAM Yes
● expandable RAM, max. 64 Mbyte
Backup
● present Yes
● with battery Yes; all data
● without battery No
Battery
Backup battery
● Backup current, typ. 190 µA; Valid up to 40°C
● Backup current, max. 660 µA
● Backup time, max. Dealt with in the module data manual with the secondary conditions and the factors of influence
● Feeding of external backup voltage to CPU 5 to 15 VDC
CPU processing times
for bit operations, typ. 0.075 µs
for word operations, typ. 0.075 µs
for fixed point arithmetic, typ. 0.075 µs
for floating point arithmetic, typ. 0.225 µs
CPU-blocks
DB
● Number, max. 4 095; Number range: 1 to 4095
● Size, max. 64 kbyte
FB
● Number, max. 2 048; Number range: 0 to 2047
● Size, max. 64 kbyte
FC
● Number, max. 2 048; Number range: 0 to 2047
● Size, max. 64 kbyte
OB
● Size, max. 64 kbyte
● Number of time alarm OBs 4
● Number of delay alarm OBs 4
● Number of time interrupt OBs 4
● Number of process alarm OBs 4
Nesting depth
● per priority class 24
● additional within an error OB 1
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2 047
— preset Z 0 to Z 7
Counting range
— lower limit 0
— upper limit 999
IEC counter
● present Yes
● Type SFB
S7 times
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2 047
— preset No times retentive
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
● Type SFB
Data areas and their retentivity
retentive data area, total Total working and load memory (with backup battery)
Flag
● Number, max. 8 kbyte
● Retentivity available Yes
● Retentivity preset MB 0 to MB 15
● Number of clock memories 8; in 1 memory byte
Data blocks
● Number, max. 4 095; Number range: 1 to 4095
● Size, max. 64 kbyte
Local data
● adjustable, max. 16 kbyte
● preset 8 kbyte
Address area
I/O address area
● Inputs 8 kbyte
● Outputs 8 kbyte
of which, distributed
— MPI/DP interface, inputs 2 kbyte
— MPI/DP interface, outputs 2 kbyte
Process image
● Inputs, adjustable 8 kbyte
● Outputs, adjustable 8 kbyte
● Inputs, default 256 byte
● Outputs, default 256 byte
● consistent data, max. 244 byte
● Access to consistent data in process image Yes
Subprocess images
● Number of subprocess images, max. 15
Digital channels
● Inputs 65 536
● Outputs 65 536
● Inputs, of which central 65 536
● Outputs, of which central 65 536
Analog channels
● Inputs 4 096
● Outputs 4 096
● Inputs, of which central 4 096
● Outputs, of which central 4 096
Hardware configuration
Expansion devices, max. 21
connectable OPs 15 without message processing, 8 with message processing
Multicomputing No
Interface modules
● Number of connectable IMs (total), max. 6
● Number of connectable IM 460s, max. 6
● Number of connectable IM 463s, max. 4; Single mode only
Number of DP masters
● Integrated 1
● Via CP 10
● Mixed mode IM + CP permitted No
● via interface module 0
Number of operable FMs and CPs (recommended)
● FM See manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections
● CP, point-to-point See manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections
● PROFIBUS and Ethernet CPs 14; Of which max. 10 CP as DP master
Slots
● Required slots 2
Time of day
Clock
● Hardware clock (real-time clock) Yes
● battery-backed and synchronizable Yes
● Resolution 1 ms
● Deviation per day (buffered), max. 1.7 s; Power off
● Deviation per day (unbuffered) max. 8.6 s; Power on
Operating hours counter
● Number 8
● Number/Number range 0 to 7
● Range of values 0 to 32767 hours
● Granularity 1 hour
● retentive Yes
Clock synchronization
● supported Yes
● to MPI, master Yes
● to MPI, slave Yes
● to DP, master Yes
● to DP, slave Yes
● in AS, master Yes
● in AS, slave Yes
Time difference in system when synchronizing via
● MPI, max. 200 ms
Digital outputs
integrated channels (DO) 0
Interfaces
Number of parallel interfaces 0
Number of 20 mA interfaces (TTY) 0
Number of RS 232 interfaces 0
Number of RS 422 interfaces 0
Number of other interfaces 0
1st interface
Interface type Integrated
Physics RS 485 / PROFIBUS + MPI
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 150 mA
Number of connection resources MPI: 16, DP: 16
Functionality
● MPI Yes
● DP master Yes
● DP slave No
MPI
● Number of connections 16
● Transmission rate, max. 12 Mbit/s
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication No
— S7 communication Yes
DP master
● Number of connections, max. 16
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 32
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— Equidistance mode support No
— SYNC/FREEZE No
— Activation/deactivation of DP slaves No
— Direct data exchange (slave-to-slave communication) No
Address area
— Inputs, max. 2 kbyte
— Outputs, max. 2 kbyte
User data per DP slave
— User data per DP slave, max. 244 byte
— Inputs, max. 244 byte
— Outputs, max. 244 byte
— Slots, max. 244
— per slot, max. 128 byte
DP slave
● Number of connections No configuration of CPU as DP slave
3rd interface
Interface type Pluggable synchronization submodule (FO)
Plug-in interface modules Synchronization submodule IF 960 6ES7 960-1AA04-0XA0
4th interface
Interface type Pluggable synchronization submodule (FO)
Plug-in interface modules Synchronization submodule IF 960 6ES7 960-1AA04-0XA0
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
equidistance No
Communication functions
PG/OP communication Yes
● Number of connectable OPs without message processing 15
● Number of connectable OPs with message processing 8
Global data communication
● supported No
S7 basic communication
● supported No
S7 communication
● supported Yes
● as server Yes
● As client Yes
● User data per job, max. 64 kbyte
● User data per job (of which consistent), max. 462 byte; 1 variable
S5-compatible communication
● supported Yes; (via CP max. 10 and FC AG_SEND and FC AG_RECV)
● User data per job, max. 8 kbyte
● User data per job (of which consistent), max. 240 byte
● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. 24/24
Standard communication (FMS)
● supported Yes; Via CP and loadable FB
Number of connections
● overall 16
● usable for PG communication
— reserved for PG communication 1
— Adjustable for PG communication, max. 0
● usable for OP communication
— reserved for OP communication 1
— adjustable for OP communication, max. 0
● usable for S7 basic communication
— Reserved for S7 basic communication 0
— adjustable for S7 basic communication, max. 0
● usable for S7 communication
— reserved for S7 communication 0
— Adjustable for S7 communication, max. 0
● usable for routing
— Reserved for routing 0
— adjustable for routing, max. 0
S7 message functions
Number of login stations for message functions, max. 8
Symbol-related messages No
Block related messages Yes
simultaneously active Alarm-S blocks, max. 100
Alarm 8-blocks Yes
● Number of instances for alarm 8 and S7 communication blocks, max. 600
● preset, max. 300
Process control messages Yes
Number of archives that can log on simultaneously (SFB 37 AR_SEND) 16
Test commissioning functions
Status block Yes
Single step Yes
Number of breakpoints 4
Status/control
● Status/control variable Yes
● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
● Number of variables, max. 70
Forcing
● Forcing Yes
● Force, variables Inputs/outputs, bit memories, distributed I/Os
● Number of variables, max. 256
Diagnostic buffer
● present Yes
● Number of entries, max. 3 200
— can be set Yes
— preset 120
Configuration
Configuration software
● STEP 7 Yes
programming
● Command set see instruction list
● Nesting levels 8
● Access to consistent data in process image Yes
● System functions (SFC) see instruction list
● System function blocks (SFB) see instruction list
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Number of simultaneously active SFCs
— RD_REC 8
— WR_REC 8
— WR_PARM 8
— PARM_MOD 1
— WR_DPARM 2
— DPNRM_DG 8
— RDSYSST 8
— DP_TOPOL 1
Number of simultaneously active SFBs
— RD_REC 8
— WR_REC 8
Know-how protection
● User program protection/password protection Yes
Dimensions
Width 50 mm
Height 290 mm
Depth 219 mm
Weights
Weight, approx. 990 g
last modified: 25.09.2014