6ES7416-3XL04-0AB0 CPU 416-3, 5,6 MB, 3 INTERFACES

Product Code: 6ES7416-3XL04-0AB0

Availability: In Stock

Price: $7,384.30
  
 
Artikelnummer 6ES7416-3XL04-0AB0
SIMATIC S7-400, CPU 416-3 CENTRAL PROCESSING UNIT WITH: 5.6 MB WORKING MEMORY, (2.8 MB CODE, 2,8 MB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE PROFIBUS DP, 3. IF IFM MODULES PLUGGABLE
General information
Firmware version V4.0
Engineering with
● Programming package STEP7 V5.2 SP1 HF3 or higher with HW update
CiR - Configuration in RUN
CiR synchronization time, basic load 100 ms
CiR synchronization time, time per I/O slave 40 µs
Supply voltage
24 V DC Yes
Input current
from backplane bus 5 V DC, typ. 1.2 A
from backplane bus 5 V DC, max. 1.4 A
from backplane bus 24 V DC, max. Total current consumption of the components connected to the MPI/DP interfaces, but no more than 150 mA per interface
Power losses
Power loss, typ. 5 W
Memory
Work memory
● integrated (for program) 2 800 kbyte
● integrated (for data) 2 800 kbyte
● expandable No
Load memory
● expandable FEPROM Yes; with Memory Card (FLASH)
● expandable FEPROM, max. 64 Mbyte
● integrated RAM, max. 256 kbyte
● expandable RAM Yes; with Memory Card (RAM)
● expandable RAM, max. 64 Mbyte
Backup
● present Yes
● with battery Yes; all data
● without battery No
Battery
Backup battery
● Backup current, typ. 550 µA
● Backup current, max. 1 530 µA
● Backup time, max. 144 d
● Feeding of external backup voltage to CPU 5 to 15 VDC
CPU processing times
for bit operations, typ. 0.04 µs
for word operations, typ. 0.04 µs
for fixed point arithmetic, typ. 0.04 µs
for floating point arithmetic, typ. 0.12 µs
CPU-blocks
DB
● Number, max. 4 095; DB 0 reserved
● Size, max. 64 kbyte
FB
● Number, max. 2 048
● Size, max. 64 kbyte
FC
● Number, max. 2 048
● Size, max. 64 kbyte
OB
● Number, max. see instruction list
● Size, max. 64 kbyte
● Number of time alarm OBs 8
● Number of delay alarm OBs 4
● Number of time interrupt OBs 9
● Number of process alarm OBs 8
● Number of multicomputing OBs 1
Nesting depth
● per priority class 24
● additional within an error OB 2
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2 047
— preset Z 0 to Z 7
Counting range
— lower limit 0
— upper limit 999
IEC counter
● present Yes
● Type SFB
S7 times
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2 047
— preset No times retentive
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
● Type SFB
Data areas and their retentivity
retentive data area, total Total working and load memory (with backup battery)
Flag
● Number, max. 16 kbyte
● Retentivity available Yes; MB 0 to MB 16383
● Retentivity preset MB 0 to MB 15
● Number of clock memories 8; 1 memory byte
Data blocks
● Number, max. 4 095; DB 0 reserved
● Size, max. 64 kbyte
Local data
● adjustable, max. 32 kbyte
● preset 16 kbyte
Address area
I/O address area
● Inputs 16 kbyte
● Outputs 16 kbyte
of which, distributed
— MPI/DP interface, inputs 2 kbyte
— MPI/DP interface, outputs 2 kbyte
— DP interface, inputs 8 kbyte; for each line that is operated in isochronous mode, i.e. to which an OB61 to 62 has been assigned, the distributed IO address areas are halved
— DP interface, outputs 8 kbyte; for each line that is operated in isochronous mode, i.e. to which an OB61 to 62 has been assigned, the distributed IO address areas are halved
Process image
● Inputs, adjustable 16 kbyte
● Outputs, adjustable 16 kbyte
● Inputs, default 512 byte
● Outputs, default 512 byte
● consistent data, max. 244 byte
● Access to consistent data in process image Yes
Subprocess images
● Number of subprocess images, max. 15
Digital channels
● Inputs 131 072
● Outputs 131 072
● Inputs, of which central 131 072
● Outputs, of which central 131 072
Analog channels
● Inputs 8 192
● Outputs 8 192
● Inputs, of which central 8 192
● Outputs, of which central 8 192
Hardware configuration
Expansion devices, max. 21; of which 6 ER with K-bus
connectable OPs 63 without message processing, 12 with message processing
Multicomputing Yes; 4 CPUs max. (with UR1 or UR2)
Interface modules
● Number of connectable IMs (total), max. 6
● Number of connectable IM 460s, max. 6
● Number of connectable IM 463s, max. 4; IM 463-2
Number of DP masters
● Integrated 2
● via IM 467 4
● Via CP 10; CP 443-5 Extended
● Mixed mode IM + CP permitted No
● via interface module 1; IF 964-DP
● Number of pluggable S5 modules (via adapter capsule in central device), max. 6
Number of operable FMs and CPs (recommended)
● FM Limited by number of slots and number of connections
● CP, point-to-point CP 440: Limited by number of slots; CP 441: limited by number of connections
● CP, LAN Limited by number of slots and number of connections
● PROFIBUS and Ethernet CPs 14; incl. CP 443-5 Ext. and IM 467
Slots
● Required slots 2
Time of day
Clock
● Hardware clock (real-time clock) Yes
● battery-backed and synchronizable Yes
● Resolution 1 ms
● Deviation per day (buffered), max. 1.7 s; Power on
● Deviation per day (unbuffered) max. 8.6 s; Power off
Operating hours counter
● Number 8
● Number/Number range 0 to 7
● Range of values 0 to 32767 hours
● Granularity 1 hour
● retentive Yes
Clock synchronization
● supported Yes
● to MPI, master Yes
● to MPI, slave Yes
● to DP, master Yes
● to DP, slave Yes
● in AS, master Yes
● in AS, slave Yes
● to IF 964 DP Yes; as Master or Slave
1st interface
Interface type Integrated
Physics RS 485 / PROFIBUS
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 150 mA
Number of connection resources MPI: 44, DP: 32
Functionality
● MPI Yes
● DP master Yes
● DP slave Yes
MPI
● Number of connections 44
● Transmission rate, max. 12 Mbit/s
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication Yes
— S7 basic communication Yes
— S7 communication Yes
DP master
● Number of connections, max. 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 32
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication Yes
— S7 basic communication Yes
— S7 communication Yes
— Equidistance mode support Yes
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) Yes
Address area
— Inputs, max. 2 kbyte
— Outputs, max. 2 kbyte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
— Slots, max. 244
— per slot, max. 128 byte
DP slave
● GSD file http://www.ad.siemens.de/csi_e/gsd
● Transmission rate, max. 12 Mbit/s
● Address area, max. 32
● User data per address area, max. 32 byte
● User data per address area, of which consistent, max. 32 byte
Services
— PG/OP communication Yes
— Routing Yes
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
2nd interface
Interface type Integrated
Physics RS 485 / PROFIBUS
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 150 mA
Number of connection resources 32
Functionality
● DP master Yes
● DP slave Yes
DP master
● Number of connections, max. 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 125
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication Yes
— S7 basic communication Yes
— S7 communication Yes
— Equidistance mode support Yes
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) Yes
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
— Slots, max. 244
— per slot, max. 128 byte
DP slave
● GSD file http://www.ad.siemens.de/csi_e/gsd
● Transmission rate, max. 12 Mbit/s
● Address area, max. 32
● User data per address area, max. 32 byte
● User data per address area, of which consistent, max. 32 byte
Services
— Routing Yes
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
3rd interface
Interface type Pluggable interface module (IF), technical data as for 2nd interface
Plug-in interface modules IF 964-DP
Isochronous mode
Isochronous operation (application synchronized up to terminal) Yes
User data per isochronous slave, max. 244 byte
equidistance Yes
shortest clock pulse 1 ms
max. cycle 32 ms
Communication functions
PG/OP communication Yes
● Number of connectable OPs without message processing 63
● Number of connectable OPs with message processing 12
Global data communication
● supported Yes
● Number of GD loops, max. 16
● Number of GD packets, transmitter, max. 16
● Number of GD packets, receiver, max. 32
● Size of GD packets, max. 64 byte
● Size of GD packet (of which consistent), max. 1 variable
S7 basic communication
● supported Yes; in MPI mode via: SFC X_SEND, X_RCV, X_GET and X_PUT; in DP master mode via: SFC I_GET and I_PUT
● User data per job, max. 76 byte
● User data per job (of which consistent), max. 1 variable
S7 communication
● supported Yes
● as server Yes
● As client Yes
● User data per job, max. 64 kbyte
● User data per job (of which consistent), max. 462 byte; 1 variable
S5-compatible communication
● supported Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5
● User data per job, max. 8 kbyte
● User data per job (of which consistent), max. 240 byte
Standard communication (FMS)
● supported Yes; Via CP and loadable FB
Number of connections
● overall 64
● usable for PG communication
— reserved for PG communication 1
● usable for OP communication
— reserved for OP communication 1
S7 message functions
Number of login stations for message functions, max. 12
Symbol-related messages Yes
Block related messages Yes
simultaneously active Alarm-S blocks, max. 200; ALARM_S/SQ blocks or ALARM_D/DQ blocks
Alarm 8-blocks Yes
● Number of instances for alarm 8 and S7 communication blocks, max. 1 800
● preset, max. 600
Process control messages Yes
Number of archives that can log on simultaneously (SFB 37 AR_SEND) 32
Number of messages
● overall, max. 1 024
● in 100 ms grid, max. 128
● in 500 ms grid, max. 512
● in 1000 ms grid, max. 1 024
Number of additional values
● with 100 ms grid, max. 1
● with 500, 1000 ms grid, max. 10
Test commissioning functions
Status block Yes
Single step Yes
Number of breakpoints 4
Status/control
● Status/control variable Yes
● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
● Number of variables, max. 70
Forcing
● Forcing Yes
● Force, variables Inputs/outputs, bit memories, distributed I/Os
● Number of variables, max. 512
Diagnostic buffer
● present Yes
● Number of entries, max. 3 200
— can be set Yes
— preset 120
Configuration
Configuration software
● STEP 7 Yes
programming
● Command set see instruction list
● Nesting levels 8
● Access to consistent data in process image Yes
● System functions (SFC) see instruction list
● System function blocks (SFB) see instruction list
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Number of simultaneously active SFCs
— DPSYC_FR 2
— D_ACT_DP 4
— RD_REC 8
— WR_REC 8
— WR_PARM 8
— PARM_MOD 1
— WR_DPARM 2
— DPNRM_DG 8
— RDSYSST 8; 1 to 8
— DP_TOPOL 1
Number of simultaneously active SFBs
— RD_REC 8
— WR_REC 8
Know-how protection
● User program protection/password protection Yes
Dimensions
Width 50 mm
Height 290 mm
Depth 219 mm
Weights
Weight, approx. 1 070 g
last modified: 25.09.2014

Write a review

Note: HTML is not translated!

Rating: Bad Good

Enter the code in the box below: