6ES7414-4HJ04-0AB0 SIMATIC S7-400H, CPU 414H

Product Code: 6ES7414-4HJ04-0AB0

Availability: In Stock

Price: $3,876.42
  
 
Artikelnummer 6ES7414-4HJ04-0AB0
SIMATIC S7-400H, CPU 414H CENTRAL UNIT FOR S7-400H AND S7-400F/FH, 4 INTERFACES: 1 MPI/DP, 1 DP AND 2 FOR SYNC MODULES, 1.4 MB MEMORY (700 KB DATA/700 KB CODE)
Supply voltage
24 V DC Yes
Input current
from backplane bus 5 V DC, typ. 1 800 A
from backplane bus 5 V DC, max. 2 A
Power losses
Power loss, typ. 4.5 W
Memory
Work memory
● integrated (for program) 700 kbyte
● integrated (for data) 700 kbyte
● expandable No
Load memory
● expandable FEPROM Yes; with Memory Card (FLASH)
● expandable FEPROM, max. 64 Mbyte
● integrated RAM, max. 256 kbyte
● expandable RAM Yes; with Memory Card (RAM)
● expandable RAM, max. 16 Mbyte
Backup
● present Yes
● with battery Yes; all data
● without battery No
Battery
Backup battery
● Backup current, typ. 550 µA
● Backup current, max. 1 530 µA
● Feeding of external backup voltage to CPU 5 to 15 VDC
CPU processing times
for bit operations, typ. 0.06 µs
for word operations, typ. 0.06 µs
for fixed point arithmetic, typ. 0.06 µs
for floating point arithmetic, typ. 0.18 µs
CPU-blocks
DB
● Number, max. 4 095; DB 0 reserved
● Size, max. 64 kbyte
FB
● Number, max. 2 048
● Size, max. 64 kbyte
FC
● Number, max. 2 048
● Size, max. 64 kbyte
OB
● Number, max. see instruction list
● Size, max. 64 kbyte
Nesting depth
● per priority class 24
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2 047
— preset Z 0 to Z 7
Counting range
— lower limit 0
— upper limit 999
IEC counter
● present Yes
● Type SFB
S7 times
● Number 2 048
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
● Type SFB
Data areas and their retentivity
Flag
● Number, max. 8 kbyte
● Retentivity available Yes; from MB 0 to MB 8191
● Retentivity preset MB 0 to MB 15
Data blocks
● Number, max. 4 096; DB 0 reserved
● Size, max. 64 kbyte
Address area
I/O address area
● Inputs 8 kbyte
● Outputs 8 kbyte
of which, distributed
— MPI/DP interface, inputs 2 kbyte
— MPI/DP interface, outputs 2 kbyte
— DP interface, inputs 6 kbyte
— DP interface, outputs 6 kbyte
Process image
● Inputs, adjustable 8 kbyte
● Outputs, adjustable 8 kbyte
● Inputs, default 1 024 byte
● Outputs, default 1 024 byte
Subprocess images
● Number of subprocess images, max. 8
Digital channels
● Inputs 65 536
● Outputs 65 536
● Inputs, of which central 65 536
● Outputs, of which central 65 536
Analog channels
● Inputs 4 096
● Outputs 4 096
● Inputs, of which central 4 096
● Outputs, of which central 4 096
Hardware configuration
Expansion devices, max. 21
Multicomputing No
Interface modules
● Number of connectable IMs (total), max. 6
● Number of connectable IM 460s, max. 6
● Number of connectable IM 463s, max. 6; IM 463-2
Number of DP masters
● Integrated 2
● via IM 467 0
● Via CP 10
● Mixed mode IM + CP permitted No; IM 467 cannot be used jointly with CP 443-5 Ext.
● via interface module 0
Number of operable FMs and CPs (recommended)
● FM 32; Limited by number of slots and number of connections
● CP, point-to-point 32; Limited by number of slots and number of connections
● CP, LAN 32; Limited by number of slots and number of connections
Slots
● Required slots 2
Time of day
Clock
● Hardware clock (real-time clock) Yes
● battery-backed and synchronizable Yes
Operating hours counter
● Number 8
Clock synchronization
● supported Yes
1st interface
Physics RS 485 / PROFIBUS
Isolated Yes
Functionality
● MPI Yes; Default setting
● DP master Yes
● DP slave No
MPI
● Number of connections 32
● Transmission rate, max. 12 Mbit/s
Services
— PG/OP communication Yes
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
DP master
● Number of connections, max. 32
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 32; Number of slots, max. 512
Services
— PG/OP communication Yes
— Global data communication No
— S7 basic communication No
— S7 communication No
— S7 communication, as client No
— S7 communication, as server No
— Equidistance mode support No
— SYNC/FREEZE No
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) No
Address area
— Inputs, max. 2 kbyte
— Outputs, max. 2 kbyte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
— Slots, max. 244
— per slot, max. 128 byte
2nd interface
Physics RS 485 / PROFIBUS
Isolated Yes
Functionality
● DP master Yes; Default setting
● DP slave No
● Point-to-point connection No
DP master
● Number of connections, max. 16
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 96
Services
— PG/OP communication Yes
— Global data communication No
— S7 basic communication No
— S7 communication No
— S7 communication, as client No
— S7 communication, as server No
— Equidistance mode support No
— SYNC/FREEZE No
— Activation/deactivation of DP slaves No
— Direct data exchange (slave-to-slave communication) No
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
Communication functions
PG/OP communication Yes
Global data communication
● supported No
S7 basic communication
● supported No
S7 communication
● supported Yes
● as server Yes
● As client Yes
● User data per job, max. 64 kbyte
S5-compatible communication
● supported Yes; via CP and loadable FC
● User data per job, max. 8 kbyte
Standard communication (FMS)
● supported Yes; Via CP and loadable FB
● User data per job, max. Dependent on CP
Number of connections
● overall 32
● usable for PG communication
— reserved for PG communication 1
— Adjustable for PG communication, max. 0
● usable for OP communication
— reserved for OP communication 1
— adjustable for OP communication, max. 0
● usable for S7 basic communication
— Reserved for S7 basic communication 0
— adjustable for S7 basic communication, max. 0
● usable for routing
— Reserved for routing 0
— adjustable for routing, max. 0
S7 message functions
Number of login stations for message functions, max. 8
Test commissioning functions
Diagnostic buffer
● present Yes
● Number of entries, max. 3 200
— can be set Yes
— preset 120
Configuration
Configuration software
● STEP 7 Yes; V5.0 SP2
programming
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Know-how protection
● User program protection/password protection Yes
Dimensions
Width 50 mm
Height 290 mm
Depth 219 mm
Weights
Weight, approx. 1 070 g
last modified: 13.10.2014

Write a review

Note: HTML is not translated!

Rating: Bad Good

Enter the code in the box below: