6ES7315-6TH13-0AB0 CPU315T-2 DP, 256KB

Product Code: 6ES7315-6TH13-0AB0

Availability: In Stock

Price: $1,607.01
  
 
Artikelnummer 6ES7315-6TH13-0AB0
Supply voltage
24 V DC Yes
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Load voltage L+
● Rated value (DC) 24 V
● Reverse polarity protection Yes
Digital outputs
Load voltage L+
— Rated value (DC) 24 V
— Reverse polarity protection No
Input current
Current consumption (in no-load operation), typ. 200 mA
Inrush current, typ. 2.5 A
I²t 1 A²·s
Power losses
Power loss, typ. 6 W
Memory
Work memory
● Integrated 256 kbyte
● expandable No
Load memory
● pluggable (MMC) Yes
● pluggable (MMC), max. 8 Mbyte
● Data management on MMC (after last programming), min. 10 y
Backup
● present Yes
● without battery Yes
CPU processing times
for bit operations, typ. 0.1 µs
for bit operations, max. 0.1 µs
for word operations, typ. 0.2 µs
for fixed point arithmetic, typ. 2 µs
for floating point arithmetic, typ. 3 µs
CPU-blocks
Number of blocks (total) 1 024
DB
● Number, max. 1 023
● Size, max. 64 kbyte
FB
● Number, max. 1 024
● Size, max. 64 kbyte
FC
● Number, max. 1 024
● Size, max. 64 kbyte
OB
● Size, max. 64 kbyte
● Number of free cycle OBs 1
● Number of time alarm OBs 1
● Number of delay alarm OBs 1
● Number of time interrupt OBs 1
● Number of process alarm OBs 1
● Number of DPV1 alarm OBs 3
● Number isochronous mode OBs 1
● Number of technology synchronous alarm OBs 1
● Number of startup OBs 1
● Number of asynchronous error OBs 5
● Number of synchronous error OBs 2
Nesting depth
● per priority class 8
● additional within an error OB 4
Counters, timers and their retentivity
S7 counter
● Number 256
Retentivity
— can be set Yes
Counting range
— can be set Yes
— lower limit 0
— upper limit 999
IEC counter
● present Yes
S7 times
● Number 256
of which retentive without battery
— can be set Yes
Retentivity
— can be set Yes
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
Data areas and their retentivity
Flag
● Number, max. 2 048 byte
● Retentivity available Yes
● Number of clock memories 8
Data blocks
● Number, max. 1 023
● Size, max. 64 kbyte
● Retentivity adjustable Yes
Local data
● per priority class, max. 1 024 byte
Address area
I/O address area
● Inputs 2 048 byte
● Outputs 2 048 byte
of which, distributed
— Inputs 2 048 byte
— Outputs 2 048 byte
Process image
● Inputs, adjustable 2 048 byte
● Outputs, adjustable 2 048 byte
● Inputs, default 128 byte
● Outputs, default 128 byte
Subprocess images
● Number of subprocess images, max. 1
Digital channels
● Inputs 16 384
● Outputs 16 384
● Inputs, of which central 512
● Outputs, of which central 512
Analog channels
● Inputs 1 024
● Outputs 1 024
● Inputs, of which central 64
● Outputs, of which central 64
Hardware configuration
Expansion devices, max. 0
Number of DP masters
● Integrated 2
● Via CP 2
Number of operable FMs and CPs (recommended)
● FM 8
● CP, point-to-point 8
● CP, LAN 10
Rack
● Racks, max. 1
● Modules per rack, max. 8
Time of day
Clock
● Hardware clock (real-time clock) Yes
● battery-backed and synchronizable Yes
● Deviation per day, max. 10 s
● Backup time 6 wk
Operating hours counter
● Number 1
● retentive Yes
Clock synchronization
● supported Yes
● to MPI, master Yes
● to MPI, slave Yes
● to DP, master Yes
● to DP, slave Yes
● in AS, master Yes
● in AS, slave Yes
Digital inputs
Number of digital inputs 4
● of which, inputs usable for technological functions 4
Input characteristic curve in accordance with IEC 61131, type 1 Yes
Number of simultaneously controllable inputs
horizontal installation
— up to 40 °C, max. 4
— up to 60 °C, max. 4
vertical installation
— up to 40 °C, max. 4
Input voltage
● Rated value, DC 24 V
Input current
● for signal "1", typ. 7 mA
Input delay (for rated value of input voltage)
for counter/technological functions
— at "0" to "1", max. 10 µs
— at "1" to "0", max. 10 µs
Cable length
● Cable length, shielded, max. 1 000 m
Digital outputs
Number of digital outputs 8
● of which high-speed outputs 8
short-circuit protection Yes
Controlling a digital input No
Switching capacity of the outputs
● Lamp load, max. 5 W
Load resistance range
● lower limit 48 Ω
● upper limit 4 kΩ
Output voltage
● for signal "0", max. 3 V
Output current
● for signal "1" rated value 0.5 A
● for signal "1" permissible range for 0 to 60 °C, min. 5 mA
● for signal "1" permissible range for 0 to 60 °C, max. 0.6 A
● for signal "0" residual current, max. 0.3 mA
Parallel switching of 2 outputs
● for increased power No
● for redundant control of a load No
Switching frequency
● with resistive load, max. 100 Hz
● with inductive load, max. 0.2 Hz
● on lamp load, max. 100 Hz
Aggregate current of outputs (per group)
horizontal installation
— up to 40 °C, max. 4 A
— up to 60 °C, max. 3 A
all other mounting positions
— up to 40 °C, max. 3 A
Cable length
● Cable length, shielded, max. 1 000 m
Analog inputs
Number of analog inputs 0
Analog outputs
Number of analog outputs 0
Encoder
Connectable encoders
● 2-wire sensor No
Interfaces
Number of RS 422 interfaces 0
Number of other interfaces 0
1st interface
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 200 mA
Functionality
● MPI Yes
● DP master Yes
● DP slave Yes
● Point-to-point connection No
MPI
● Number of connections 32
● Transmission rate, max. 12 Mbit/s
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication Yes
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
DP master
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 124
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
— Equidistance mode support Yes
— Isochronous mode Yes
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— DPV1 Yes
Address area
— Inputs, max. 2 048 byte
— Outputs, max. 2 048 byte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
DP slave
● Transmission rate, max. 12 Mbit/s
● Automatic baud rate search No
● Address area, max. 32
● User data per address area, max. 32 byte
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV1 No
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
2nd interface
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 200 mA
Functionality
● MPI No
● DP master Yes
● DP slave No
● Point-to-point connection No
DP master
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 64
Services
— PG/OP communication No
— Routing No
— Global data communication No
— S7 basic communication No
— S7 communication No
— Equidistance mode support Yes
— Isochronous mode Yes
— SYNC/FREEZE No
— Activation/deactivation of DP slaves Yes
— DPV1 No
Address area
— Inputs, max. 1 024 byte
— Outputs, max. 1 024 byte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
DP slave
● Transmission rate, max. 12 Mbit/s
Communication functions
PG/OP communication Yes
Global data communication
● supported Yes
● Number of GD loops, max. 8
● Number of GD packets, max. 8
● Number of GD packets, transmitter, max. 8
● Number of GD packets, receiver, max. 8
● Size of GD packets, max. 22 byte
● Size of GD packet (of which consistent), max. 22 byte
S7 basic communication
● supported Yes
● User data per job, max. 76 byte
● User data per job (of which consistent), max. 76 byte
S7 communication
● supported Yes
● as server Yes
● As client Yes
S5-compatible communication
● supported Yes
Number of connections
● overall 16
● usable for PG communication 15
— reserved for PG communication 1
— Adjustable for PG communication, min. 1
— Adjustable for PG communication, max. 15
● usable for OP communication 15
— reserved for OP communication 1
— adjustable for OP communication, min. 1
— adjustable for OP communication, max. 15
● usable for S7 basic communication 12
— Reserved for S7 basic communication 0
— adjustable for S7 basic communication, min. 0
— adjustable for S7 basic communication, max. 12
● usable for routing 8
S7 message functions
Number of login stations for message functions, max. 16
Process diagnostic messages Yes
simultaneously active Alarm-S blocks, max. 40
Test commissioning functions
Status block Yes
Single step Yes
Number of breakpoints 2
Status/control
● Status/control variable Yes
● Number of variables, max. 30
● of which status variables, max. 30
● of which control variables, max. 14
Forcing
● Forcing Yes
● Number of variables, max. 10
Diagnostic buffer
● present Yes
● Number of entries, max. 100
— can be set No
Interrupts/diagnostics/status information
Alarms
● Alarms No
Diagnostic messages
● Diagnostic functions No
Diagnostics indication LED
● Status indicator digital output (green) Yes
● Status indicator digital input (green) Yes
Galvanic isolation
Galvanic isolation digital inputs
● between the channels and the backplane bus Yes
Galvanic isolation digital outputs
● between the channels and the backplane bus Yes
Ambient conditions
Operating temperature
● Min. 0 °C
● max. 60 °C
Configuration
Configuration software
● STEP 7 Yes
programming
● Nesting levels 8
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Know-how protection
● User program protection/password protection Yes
Cycle time monitoring
● lower limit 1 ms
● upper limit 6 000 ms
● can be set Yes
● preset 150 ms
Dimensions
Width 160 mm
Height 125 mm
Depth 130 mm
Weights
Weight, approx. 750 g
last modified: 16.09.2014