SIMATIC DP, DISTRIBUTED I/O ET200X:BASIC MOD. BM143/DESINA 8DI/DO CONFIGURABLE,ADD.DIAG- INPUTS,HYBRID FIELD BUS INTERF. (RS485), IDENT CONNECTOR, IP67 |
|
Supply voltage |
Load voltage 1L+ |
Rated value (DC) |
24 V |
Reverse polarity protection |
No |
Load voltage 2L+ |
Rated value (DC) |
24 V |
Reverse polarity protection |
No |
Input current |
from load voltage 1L+ (unswitched voltage) |
180 mA |
from load circuit 1 (unswitched voltage/supply voltage) up to 40 °C |
10 A |
from load circuit 1 (unswitched voltage/supply voltage) up to 55 °C |
8 A |
from load circuit 2 (unswitched voltage/supply voltage) up to 40 °C |
10 A |
from load circuit 2 (unswitched voltage/supply voltage) up to 55 °C |
8 A |
Power losses |
Power loss, typ. |
3.5 W |
Hardware configuration |
Expansion modules |
Number of expansion modules, max. |
7 |
of which motor starters/frequency converters, max. |
6 |
of which, pneumatic interfaces, max. |
6 |
Digital inputs |
Number of digital inputs |
8; 8 process channels, parameterization as DI/DO; 8 function channels, parameter assignment as diagnostics/NC input |
Input characteristic curve in accordance with IEC 61131, type 2 |
Yes |
Input voltage |
Rated value, DC |
24 V; Input voltage for parameterized DI (Pin 4): Rated value 24 VDC, for signal "1": 13 to 30 V, for signal "0": -30 to +5 V: Input voltage for input functionality (Pin 2): Rated value 24 VDC, for signal "1": 13 to 30 VDC, for signal "0": -30 to +2 V |
for signal "0" |
-3 to +5 V |
for signal "1" |
13 to 30 V |
Input current |
for signal "1", typ. |
5 mA |
Input delay (for rated value of input voltage) |
for standard inputs |
at "0" to "1", min. |
1.2 ms |
at "0" to "1", max. |
4.8 ms |
Cable length |
Cable length unshielded, max. |
30 m; for signal lines |
Digital outputs |
Number of digital outputs |
8; 8 process channels, parameterization as DI/DO; 8 function channels, parameter assignment as diagnostics/NC input |
Short-circuit protection |
Yes; Electronic |
Response threshold, typ. |
1,8 A |
Switching capacity of the outputs |
Lamp load, max. |
10 W |
Output current |
for signal "1" rated value |
1.2 A |
for signal "1" permissible range for 0 to 60 °C, min. |
5 mA |
for signal "1" permissible range for 0 to 60 °C, max. |
1.3 A |
for signal "0" residual current, max. |
0.5 mA |
Switching frequency |
with resistive load, max. |
100 Hz |
with inductive load, max. |
2 Hz |
on lamp load, max. |
1 Hz |
Aggregate current of outputs (per group) |
all mounting positions |
up to 60 °C, max. |
Simultaneity factor 50% |
Cable length |
Cable length unshielded, max. |
30 m |
Encoder |
Connectable encoders |
2-wire sensor |
Yes |
Permissible quiescent current (2-wire sensor), max. |
1.5 mA |
1st interface |
Functionality |
DP slave |
Yes |
DP slave |
Transmission rate, min. |
9.6 kbit/s |
Transmission rate, max. |
12 Mbit/s; 9,6 / 19,2 / 45,45 / 93,75 / 187,5 / 500 kbit/s; 1,5 / 12 Mbit/s |
Services |
Direct data exchange (slave-to-slave communication) |
Yes; Sender |
Interrupts/diagnostics/status information |
Alarms |
Diagnostic alarm |
Yes |
Diagnostic messages |
Diagnostics |
Yes; complying with DESINA |
Diagnostics indication LED |
Group error SF (red) |
Yes |
Galvanic isolation |
Galvanic isolation |
No electrical isolation between the load voltages and between the load voltages and all the other circuit components |
between PROFIBUS DP and all other circuit components |
Yes |
Galvanic isolation digital inputs |
between the channels |
No |
between the channels and the backplane bus |
No |
Degree and class of protection |
IP67 |
Yes |
Dimensions |
Width |
175 mm; 180 when screw mounted |
Height |
180 mm; 174 when screw mounted |
Depth |
110 mm; 90 when screw mounted |
Status |
Jun 16, 2014 |