6ES7677-1DD00-0BF0 S7-MEC, EC31-HMI/RTX 128 PT

Product Code: 6ES7677-1DD00-0BF0

Availability: In Stock

Price: $1,911.15
Artikelnummer 6ES7677-1DD00-0BF0
SIMATIC S7-MODULAR EMBEDDED CONTROLLER, EC31-HMI/RTX, 1 GB RAM, 2 GB FLASH DISK WITH PREINSTALLED SW: WINDOWS XP EMBEDDED; SIMATIC WINAC RTX, SIMATIC SOFTNET-S7/ LEAN, WINCC FLEXIBLE RT 128 PT, (INCL. SMART ACCESS, ARCHIVES AND RECIPES), INTERFACES: 1. IF: 2 X PROFINET, 2. IF: 1 X FAST ETHERNET, 3. IF: 2 X USB, MMC SLOT, DOCUMENTATION ON CD/DVD, RESTORE CD/DVD
General information
Hardware product version 04
Firmware version V1.3
PC configuration
Computer platform SIMATIC S7 modular embedded controller
Processor selection Intel Core Duo 1.2 GHz
Main memory 1 GB RAM
Flash Disk 2 Gbyte
Operating systems Windows XP embedded SP2 FP2007
Installed software
● Visualization WinCC flexible RT 2008
● Control SIMATIC WinAC RTX 2009
● Communication Yes
Supply voltage
Rated value, 24 V DC Yes
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Mains buffering
● Mains/voltage failure stored energy time 5 ms
Input current
Rated value at 24 V DC 800 mA; without backplane bus and USB power supply
Power losses
Power loss, typ. 34 W
Memory
Type of memory 512 KB non-volatile memory for retentive data
Work memory
● Integrated 1 Gbyte
CPU processing times
for bit operations, typ. 0.004 µs; Typical
for fixed point arithmetic, typ. 0.003 µs; Typical
for floating point arithmetic, typ. 0.004 µs; Typical
CPU-blocks
DB
● Number, max. Max. code size and max. data size: 4 MB each
● Size, max. 64 kbyte
FB
● Number, max. Max. code size and max. data size: 4 MB each
● Size, max. 64 kbyte
FC
● Number, max. Max. code size and max. data size: 4 MB each
● Size, max. 64 kbyte
OB
● Number, max. Max. code size and max. data size: 4 MB each
● Size, max. 64 kbyte
● Number of free cycle OBs 1; OB 1
● Number of time alarm OBs 1; OB 10
● Number of delay alarm OBs 1; OB 20
● Number of time interrupt OBs 9; OB 30-38
● Number of process alarm OBs 1; OB 40
● Number of startup OBs 2; OB 100, 102
● Number of asynchronous error OBs 7; OB 80, 82-85, 86, 88
● Number of synchronous error OBs 2; OB 121, 122
Nesting depth
● per priority class 24
● additional within an error OB 24
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2 047
— preset 8
Counting range
— can be set Yes
— lower limit 0
— upper limit 999
IEC counter
● present Yes
● Type SFB
S7 times
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2 047
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
● Type SFB
Data areas and their retentivity
retentive data area, total 512 KB
Flag
● Number, max. 16 kbyte
● of which retentive without battery MB 0 to MB 16383
● Retentivity preset MB 0 to MB 15
● Number of clock memories 8
Data blocks
● Number, max. Max. code size and max. data size: 4 MB each
● Size, max. 64 kbyte
Address area
I/O address area
● Inputs 16 kbyte
● Outputs 16 kbyte
of which, distributed
— Inputs 8 kbyte
— Outputs 8 kbyte
Process image
● Inputs, adjustable 8 kbyte
● Outputs, adjustable 8 kbyte
● Inputs, default 512 byte
● Outputs, default 512 byte
Subprocess images
● Number of subprocess images, max. 15
Digital channels
● Inputs 128 000
● Outputs 128 000
Analog channels
● Inputs 8 000
● Outputs 8 000
Hardware configuration
Integrated power supply Yes
Time of day
Clock
● Hardware clock (real-time clock) Yes; Resolution: 1 s
Clock synchronization
● supported Yes
● to PC-CP, slave Yes
● on Ethernet via NTP Yes
Interfaces
Number of USB interfaces 2
USB port 2 x USB 2.0 high speed/high current
serial interface 0
Industrial Ethernet
● Industrial Ethernet interface X1: 2 ports 10/100 Mbit/s (ERTEC-based) X2: 1 port 10/100 Mbit/s
1st interface
Interface type PROFINET
Physics 2x RJ45
Automatic detection of transmission speed Yes
Autonegotiation Yes
Autocrossing Yes
Number of connection resources 32
Functionality
● MPI No
● DP master No
● DP slave No
● PROFINET IO Device No
● PROFINET IO Controller Yes
● PROFINET CBA Yes
● Open IE communication Yes
● Point-to-point connection No
PROFINET IO Controller
● Number of connectable IO devices, max. 256
● Number of IO devices with IRT and the option "high flexibility" 64
● IRT, supported Yes
● Prioritized startup supported Yes
— Number of IO Devices, max. 32
● Activation/deactivation of IO Devices Yes
— Maximum number of IO devices that can be activated/deactivated at the same time. 8
● IO Devices changing during operation (partner ports), supported Yes
— Max. number of IO devices per tool 8
● Send cycles Adjustable: 250 µs, 500 µs and 1 ms
● Updating times 250 µs - 128 ms (with signal cycle 250 µs); 500 µs - 256 ms (with signal cycle 500 µs); 1 ms - 512 ms (with signal cycle 1 ms)
Services
— PG/OP communication Yes
— S7 routing Yes
— S7 communication Yes
— Isochronous mode No
Address area
— Inputs, max. 16 kbyte
— Outputs, max. 16 kbyte
— User data per address area, max. 2 kbyte
— User data consistency, max. 256 byte
PROFINET CBA
● acyclic transmission Yes
● Cyclic transmission Yes
Open IE communication
● Open IE communication, supported Yes
● Number of connections, max. 32
● Local port numbers used at the system end 0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
PROFINET functions
● Detection of accessible nodes, supported Yes; DCP
● Assignment of the IP address, supported Yes; DCP
● Assignment of the device name, supported Yes; DCP
● Topology recognition, supported Yes; LLDP, LLDP MIB, SNMP
● Extended network diagnostics with Standard MIB II, supported Yes; Standard MIB II, SNMP
2nd interface
Interface type Integrated Ethernet interface
Physics Ethernet RJ45
Automatic detection of transmission speed Yes
Autonegotiation Yes
Autocrossing No
Number of connection resources 32
Functionality
● PROFINET IO Controller No
● PROFINET IO Device No
● PROFINET CBA No
Communication functions
PG/OP communication Yes
Global data communication
● supported No
S7 basic communication
● supported No
S7 communication
● supported Yes
● as server Yes
● As client Yes
Open IE communication
● TCP/IP Yes; Via integrated PROFINET interface (X1) and loadable FBs
— Number of connections, max. 32
— Data length, max. 8 192 byte
● ISO-on-TCP (RFC1006) No
● UDP Yes; Via integrated PROFINET interface (X1) and loadable FBs
— Number of connections, max. 32
— Data length, max. 1 472 byte
Number of connections
● overall 64
● usable for PG communication
— reserved for PG communication 1
● usable for OP communication
— reserved for OP communication 1
S7 message functions
Number of login stations for message functions, max. 62; The alarm functions cannot currently be used for central bus modules
Process diagnostic messages Yes; Alarm_S
Test commissioning functions
Status/control
● Status/control variable Yes
Forcing
● Forcing No
Diagnostic buffer
● present Yes
EMC
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes
Degree and class of protection
Degree of protection to EN 60529
● IP20 Yes
Standards, approvals, certificates
CE mark Yes
CSA approval Yes; Included in cULus
cULus Yes
RCM (formerly C-TICK) Yes
FM approval Yes
Ambient conditions
Operating temperature
● Min. 0 °C
● max. 50 °C
Storage/transport temperature
● Min. -40 °C
● max. 70 °C
Vibrations
● Operation, checked according to IEC 60068-2-6 Yes
● Transport tested checked to IEC 60068-2-6 Yes
Shock test
● checked according to IEC 60068-2-27 Yes
● checked according to IEC 60068-2-29 Yes
Shock testing
● checked according to IEC 60068-2-29 Yes
● Operation, checked according to IEC 60068-2-29 Operation, tested according to IEC 60068-2-27
● Storage/transport, checked to IEC 60068-2-29 Yes
Configuration
Configuration software
● STEP 7 Yes
programming
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Dimensions
Width 160 mm
Height 125 mm
Depth 115 mm
last modified: 14.10.2014