Product type designation |
SCALANCE X302-7EEC |
Product description |
|
|
SCALANCE X302-7EEC; MANAGED IE SWITCH, COMPACT; 2 X 10/100/1000MBIT/S RJ45; 7 X 100MBIT/S LC FO PORTS; 24 V DC POWER SUPPLY; LED-DIAGNOSTICS; FAULT SIGNAL CONTACT; SELECT/SET-BUTTON; PROFINET-IO DEVICE; NETWORK- MANAGEMENT; INTEGRATED REDUNDANCY MANAGER; OFFICE FEATURES (RSTP, VLAN, IGMP,..); C-PLUG IN SCOPE OF SUPPLY |
Transmission rate |
Transfer rate |
10 Mbit/s, 100 Mbit/s, 1000 Mbit/s |
Interfaces |
Number of electrical/optical connections |
|
● for network components or terminal equipment / maximum |
9 |
Number of electrical connections |
|
● for network components or terminal equipment |
2 |
● for signaling contact |
1 |
● for power supply |
1 |
● for redundant voltage supply |
1 |
Design of the electrical connection |
|
● for network components or terminal equipment |
RJ45 port |
● for signaling contact |
2-pole terminal block |
● for power supply |
4-pole terminal block |
Number of optical interfaces |
|
● for fiber optic cable / at 100 Mbit/s |
7 |
Design of the optical interface |
|
● for fiber optic cable / at 100 Mbit/s |
LC port (multimode up to 5 km) |
Connectable optical power relative to 1 mW |
|
● of the transmitter output / minimum |
-19 dB |
● of the transmitter output / maximum |
-14 dB |
● of the receiver input / maximum |
-14 dB |
Optical sensitivity relating to 1 mW / of the receiver input / minimum |
-32 dB |
Damping ratio / of the FOC transmission link / minimum necessary |
0 dB |
Range / at the optical interface / depending on the optical fiber used |
0 ... 5 km |
design of the removable storage / C-PLUG |
Yes |
Signal-Inputs/outputs |
Operating voltage / of the signaling contacts |
|
● for DC / Rated value |
24 V |
Operating current / of the signaling contacts |
|
● for DC / maximum |
0.1 A |
Supply voltage, current consumption, power loss |
Type of voltage supply / redundant power supply unit |
No |
Type of voltage / of the supply voltage |
DC |
Supply voltage |
|
● external |
24 V |
● external |
19.2 ... 57.6 V |
Supply voltage / 2 / Rated value |
|
● Type of voltage / 2 / of the supply voltage |
DC |
Supply voltage |
|
● for DC |
24 V |
● for DC / Rated value / minimum |
19.2 V |
● for DC / Rated value / maximum |
57.6 V |
Product component / fusing at power supply input |
Yes |
Fuse protection type / at input for supply voltage |
T 4 A / 125 V |
Consumed current / maximum |
0.75 A |
Active power loss |
|
● for DC / at 24 V |
17 W |
Permitted ambient conditions |
Ambient temperature |
|
● during operation |
-40 ... +70 °C |
● during storage |
-40 ... +70 °C |
● during transport |
-40 ... +70 °C |
● Note |
A maximum operating temperature of +85 °C is permissible for a duration of 16 hours |
Relative humidity |
|
● at 25 °C / without condensation / during operation / maximum |
95 % |
Ambient condition / for operation |
Conformal coating, no |
Coating |
Conformal Coating, no |
Protection class IP |
IP30 |
Design, dimensions and weight |
Design |
compact |
Width |
216 mm |
Height |
143 mm |
Depth |
110 mm |
Net weight |
1.8 kg |
Mounting type |
Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate |
● 19-inch installation |
Yes |
● 35 mm DIN rail mounting |
Yes |
● wall mounting |
Yes |
● S7-300 rail mounting |
Yes |
● S7-1500 rail mounting |
No |
Product properties, functions, components / general |
Cascading in cases of star topology |
Any (depending only on signal propagation time) |
Product functions / management, configuration |
Product function |
|
● CLI |
Yes |
● web-based management |
Yes |
● MIB support |
Yes |
● TRAPs via email |
Yes |
● Configuration with STEP 7 |
Yes |
● RMON |
Yes |
● Port mirroring |
Yes |
● multiport mirroring |
Yes |
● CoS |
Yes |
● with IRT / PROFINET IO switch |
No |
● PROFINET IO diagnosis |
Yes |
● switch-managed |
Yes |
Protocol / is supported |
|
● Telnet |
Yes |
● HTTP |
Yes |
● HTTPS |
Yes |
● TFTP |
Yes |
● FTP |
Yes |
● BOOTP |
Yes |
● GMRP |
Yes |
● DCP |
Yes |
● LLDP |
Yes |
● IGMP (snooping/querier) |
Yes |
Identification & maintenance function |
|
● I&M0 - device-specific information |
Yes |
● I&M1 – higher-level designation/location designation |
Yes |
Protocol / is supported |
|
● SNMP v1 |
Yes |
● SNMP v2 |
Yes |
● SNMP v3 |
Yes |
Product functions / Diagnosis |
Product function |
|
● Port diagnostics |
Yes |
● Statistics Packet Size |
Yes |
● Statistics packet type |
Yes |
● Error statistics |
Yes |
● SysLog |
Yes |
Product functions / VLAN |
Product function |
|
● VLAN - port based |
Yes |
● VLAN - protocol-based |
No |
● VLAN - IP-based |
No |
● VLAN dynamic |
Yes |
Number of VLANs / maximum |
255 |
Number of VLANs - dynamic / maximum |
255 |
Protocol / is supported / GVRP |
Yes |
Product functions / DHCP |
Product function |
|
● DHCP client |
Yes |
● DHCP Option 82 |
Yes |
● DHCP Option 66 |
Yes |
● DHCP Option 67 |
Yes |
Product functions / Redundancy |
Product function |
|
● Ring redundancy |
Yes |
● High Speed Redundancy Protocol (HRP) |
Yes |
● high speed redundancy protocol (HRP) with redundancy manager |
Yes |
● high speed redundancy protocol (HRP) with standby redundancy |
Yes |
● Media Redundancy Protocol (MRP) |
Yes |
● media redundancy protocol (MRP) with redundancy manager |
Yes |
● redundancy procedure STP |
Yes |
● redundancy procedure RSTP |
Yes |
● redundancy procedure MSTP |
Yes |
● Passive listening |
Yes |
Protocol / is supported |
|
● STP/RSTP |
Yes |
● STP |
Yes |
● RSTP |
Yes |
● MSTP |
No |
● RSTP big network support |
Yes |
● LACP |
Yes |
Product functions / Security |
Product function |
|
● ACL - MAC-based |
Yes |
● ACL - port/MAC-based |
Yes |
● IEEE 802.1x (radius) |
Yes |
● Broadcast/Multicast/Unicast Limiter |
Yes |
● broadcast blocking |
Yes |
Protocol / is supported |
|
● SSH |
Yes |
Product functions / Time |
Product function |
|
● SICLOCK support |
Yes |
Protocol / is supported |
|
● NTP |
Yes |
● SNTP |
Yes |
● IEEE 1588 profile default |
Yes |
Standards, specifications, approvals |
Standard |
|
● for EMC |
IEC 61850, IEEE 1613 |
● for FM |
FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
● for hazardous zone |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 |
● for safety / from CSA and UL |
UL 508 |
● for hazardous zone / from CSA and UL |
ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 |
● for emitted interference |
EN 61000-6-4:2007 (Class A) |
● for interference immunity |
EN 61000-6-2:2005 |
Certificate of suitability |
EN 61000-6-2:2005, EN 61000-6-4:2007 |
● CE marking |
Yes |
● C-Tick |
Yes |
● KC approval |
Yes |
● Railway application in accordance with EN 50155 |
No |
● Railway application in accordance with EN 50124-1 |
No |
● IEC 61850-3 |
Yes |
● IEEE 1613 |
Yes |
MTBF / at 40 °C |
27.2 y |
Further Information / Internet Links |
Internet-Link |
|
● to website: Selector SIMATIC NET SELECTION TOOL |
http://www.siemens.com/snst |
● to website: Industrial communication |
http://www.siemens.com/simatic-net |
● to website: Information and Download Center |
http://www.siemens.com/automation/net/catalog |
● to website: Image database |
http://automation.siemens.com/bilddb |
● to website: CAx Download Manager |
http://www.siemens.com/cax |
● to website: Industry Online Support |
http://support.automation.siemens.com |
Security information |
Security information |
Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4) |
last modified: |
04.11.2014 |
Date 04.11.2014 |
Changes preserved © Copyright Siemens AG 2014 |