6GK5414-3FC00-2AA2 SCALANCE X414-3E

Product Code: 6GK5414-3FC00-2AA2

Availability: In Stock

Price: $1,712.50
Artikelnummer 6GK5414-3FC00-2AA2
Product type designation SCALANCE X414-3E
Product description
SCALANCE X414-3E, MODULAR IE SWITCH, 2 X 10/100/1000MBIT/S AND 12 X 10/100MBIT/S RJ45 PORTS, 1 X GIGAGBIT AND 2 X 100 MBIT MEDIA MODULE SLOTS, EXTENDER INTERFACE, INTEGRATED REDUNDANCY MANAGER, OFFICE FEATURES (RSTP, VLAN,..) NETWORK MANAGEMENT, C-PLUG INCLUDED IN THE SCOPE OF SUPPLY
Transmission rate
Transfer rate 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s
Interfaces
Number of electrical/optical connections
● for network components or terminal equipment / maximum 26
Number of electrical connections
● for network components or terminal equipment 14
● for network components or terminal equipment / with extender modules 8
● for operator console 1
● for management purposes 1
● for signaling contact 1
● for media module 3
● for power supply 1
● for redundant voltage supply 1
Design of the electrical connection
● for network components or terminal equipment RJ45 port (2 x 1GE, 12 x FE)
● for network components or terminal equipment / with extender modules RJ45 port via EM495-8
● for operator console RS232 port
● for management purposes RJ45 port
● for signaling contact 4-pole terminal block
● for power supply 4-pole terminal block
Number of optical interfaces
● for fiber optic cable / at 100 Mbit/s 4
● for fiber optic cable / at 1000 Mbit/s 2
● for fiber optic cable / with extender modules 8
Design of the optical interface
● for fiber optic cable / at 100 Mbit/s BFOC or SC ports via media modules MM491-2, MM491-2LD, MM491-2LH+
● for fiber optic cable / at 1000 Mbit/s SC ports via media modules MM492-2, MM492-2LD, MM492-2LH, MM492-2LH+
● for fiber optic cable / with extender modules BFOC or SC ports via media modules MM491-2, MM491-2LD, MM491-2LH+, MM492-2, MM492-2LD, MM492-2LH, MM492-2LH+
Number of extender expansion interfaces 1
Extender extension interface version EM495-8 or EM496-4
design of the removable storage / C-PLUG Yes
Signal-Inputs/outputs
Operating voltage / of the signaling contacts
● for DC / Rated value 24 V
Operating current / of the signaling contacts
● for DC / maximum 0.1 A
Number of digital inputs 2
Number of electrical connections / for digital input signals 2
Design of the electrical connection / for digital input signals 5-pole terminal block
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltage DC
Supply voltage
● external 24 V
● external 20.4 ... 28.8 V
Product component / fusing at power supply input Yes
Fuse protection type / at input for supply voltage F 3,15 A / 250 V
Consumed current / maximum 2 A
Active power loss
● for DC / at 24 V 15 W
● maximum 48 W
Permitted ambient conditions
Ambient temperature
● during operation -40 ... +70 °C
● during storage -40 ... +80 °C
● during transport -40 ... +80 °C
Relative humidity
● at 25 °C / without condensation / during operation / maximum 95 %
Protection class IP IP20
Design, dimensions and weight
Design Modular
Width 344 mm
Height 145 mm
Depth 117 mm
Net weight 3.07 kg
Mounting type
● 35 mm DIN rail mounting Yes
● wall mounting No
● S7-300 rail mounting Yes
● S7-1500 rail mounting No
Product properties, functions, components / general
Cascading in the case of a redundant ring / at reconfiguration time of <~0.3~s 50
Cascading in cases of star topology Any (depending only on signal propagation time)
Product functions / management, configuration
Product function
● CLI Yes
● web-based management Yes
● MIB support Yes
● TRAPs via email Yes
● Configuration with STEP 7 Yes
● RMON Yes
● Port mirroring Yes
● multiport mirroring No
● CoS Yes
● PROFINET IO diagnosis Yes
● switch-managed Yes
Protocol / is supported
● Telnet Yes
● HTTP Yes
● HTTPS Yes
● TFTP Yes
● FTP Yes
● BOOTP Yes
● GMRP Yes
● DCP Yes
● LLDP Yes
● IGMP (snooping/querier) Yes
Identification & maintenance function
● I&M0 - device-specific information Yes
● I&M1 – higher-level designation/location designation Yes
Protocol / is supported
● SNMP v1 Yes
● SNMP v2 Yes
● SNMP v3 Yes
Product functions / Diagnosis
Product function
● Port diagnostics Yes
● Statistics Packet Size Yes
● Statistics packet type Yes
● Error statistics Yes
● SysLog Yes
Product functions / VLAN
Product function
● VLAN - port based Yes
● VLAN - protocol-based No
● VLAN - IP-based No
● VLAN dynamic Yes
Number of VLANs / maximum 64
Number of VLANs - dynamic / maximum 64
Protocol / is supported / GVRP Yes
Product functions / DHCP
Product function
● DHCP client Yes
● DHCP Option 82 Yes
● DHCP Option 66 Yes
● DHCP Option 67 Yes
Product functions / Routing
Product function
● Static IP routing Yes
● Static IP routing IPv6 No
● dynamic IP routing Yes
● dynamic IP routing IPv6 No
Protocol / is supported
● RIPv2 Yes
● RIPnG for IPv6 No
● OSPFv2 Yes
● OSPFv3 for IPv6 No
● VRRP Yes
● VRRP for IPv6 No
Product functions / Redundancy
Product function
● Ring redundancy Yes
● High Speed Redundancy Protocol (HRP) Yes
● high speed redundancy protocol (HRP) with redundancy manager Yes
● high speed redundancy protocol (HRP) with standby redundancy Yes
● Media Redundancy Protocol (MRP) Yes
● media redundancy protocol (MRP) with redundancy manager Yes
● redundancy procedure STP Yes
● redundancy procedure RSTP Yes
● redundancy procedure MSTP No
● Passive listening Yes
Protocol / is supported
● RSTP big network support Yes
● LACP Yes
Product functions / Security
Product function
● ACL - MAC-based Yes
● ACL - port/MAC-based Yes
● IEEE 802.1x (radius) Yes
● Broadcast/Multicast/Unicast Limiter Yes
● broadcast blocking Yes
Protocol / is supported
● SSH Yes
Product functions / Time
Product function
● SICLOCK support Yes
Protocol / is supported
● NTP No
● SNTP Yes
● IEEE 1588 profile default No
Standards, specifications, approvals
Standard
● for FM FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4
● for hazardous zone EN 60079-0: 2009, EN60079-15: 2010, II 3 G Ex nA IIC T4 Gc, KEMA 07 ATEX 0145 X
● for safety / from CSA and UL UL 60950-1, CSA C22.2 No. 60950-1-03
● for hazardous zone / from CSA and UL ISA 12.12.01-2012 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4
● for emitted interference EN 61000-6-4:2001 (Class A)
● for interference immunity EN 61000-6-2:2001
Certificate of suitability EN 61000-6-2:2001, EN 61000-6-4:2001
● CE marking Yes
● C-Tick Yes
● KC approval Yes
● Railway application in accordance with EN 50155 No
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS) Yes
● Bureau Veritas (BV) Yes
● Det Norske Veritas (DNV) Yes
● Germanische Lloyd (GL) Yes
● Lloyds Register of Shipping (LRS) Yes
● Nippon Kaiji Kyokai (NK) Yes
● Polski Rejestr Statkow (PRS) Yes
MTBF / at 40 °C 18 y
Further Information / Internet Links
Internet-Link
● to website: Selector SIMATIC NET SELECTION TOOL http://www.siemens.com/snst
● to website: Industrial communication http://www.siemens.com/simatic-net
● to website: Information and Download Center http://www.siemens.com/automation/net/catalog
● to website: Image database http://automation.siemens.com/bilddb
● to website: CAx Download Manager http://www.siemens.com/cax
● to website: Industry Online Support http://support.automation.siemens.com
Security information
Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4)
last modified: 23.10.2014
Date
30.10.2014
Changes preserved
© Copyright Siemens AG 2014

Write a review

Note: HTML is not translated!

Rating: Bad Good

Enter the code in the box below: