Product type designation |
SCALANCE X108PoE |
Product description |
|
|
SCALANCE X108POE UNMANAGED IE SWITCH, 2 X 10/100MBIT/S RJ45 POWER OVER ETHERNET PORTS AND 6 X 10/100MBIT/S RJ45 PORTS, LED-DIAGNOSIS, FAULT SIGNAL. CONTACT WITH SET BUTTON, REDUNDANT POWER SUPPLY |
Transmission rate |
Transfer rate |
10 Mbit/s, 100 Mbit/s |
Interfaces |
Number of electrical/optical connections |
|
● for network components or terminal equipment / maximum |
8 |
Number of electrical connections |
|
● for network components or terminal equipment |
6 |
● for Power-over-Ethernet / for network components or terminal equipment |
2 |
● for signaling contact |
1 |
● for power supply |
1 |
● for redundant voltage supply |
1 |
Design of the electrical connection |
|
● for network components or terminal equipment |
RJ45 port |
● for Power-over-Ethernet / for network components or terminal equipment |
RJ45 port |
● for signaling contact |
2-pole terminal block |
● for power supply |
4-pole terminal block |
Signal-Inputs/outputs |
Operating voltage / of the signaling contacts |
|
● for DC / Rated value |
24 V |
Operating current / of the signaling contacts |
|
● for DC / maximum |
0.1 A |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage |
DC |
Supply voltage |
|
● external |
24 V |
● external |
18 ... 32 V |
Product component / fusing at power supply input |
Yes |
Fuse protection type / at input for supply voltage |
4 A / 125 V |
Consumed current / maximum |
1.7 A |
Active power loss |
|
● for DC / at 24 V |
10 W |
Permitted ambient conditions |
Ambient temperature |
|
● during operation |
-20 ... +60 °C |
● during storage |
-40 ... +80 °C |
● during transport |
-40 ... +80 °C |
● Note |
At 55° C ambient temperature on both sides 40 mm distance to adjacent devices |
Relative humidity |
|
● at 25 °C / without condensation / during operation / maximum |
95 % |
Ambient condition / for operation |
Conformal coating, no |
Coating |
Conformal Coating, no |
Protection class IP |
IP30 |
Design, dimensions and weight |
Design |
compact |
Width |
60 mm |
Height |
125 mm |
Depth |
124 mm |
Net weight |
0.9 kg |
Mounting type |
|
● 35 mm DIN rail mounting |
Yes |
● wall mounting |
Yes |
● S7-300 rail mounting |
Yes |
● S7-1500 rail mounting |
No |
Product functions / management, configuration |
Product function |
|
● multiport mirroring |
No |
● switch-managed |
No |
Standards, specifications, approvals |
Standard |
|
● for FM |
FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
● for hazardous zone |
EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X |
● for safety / from CSA and UL |
UL 60950-1, CSA C22.2 No. 60950-1 |
● for hazardous zone / from CSA and UL |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
● for emitted interference |
EN 61000-6-4:2001 |
● for interference immunity |
EN 61000-6-2:2001 |
Certificate of suitability |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
● CE marking |
Yes |
● C-Tick |
Yes |
● KC approval |
Yes |
● Railway application in accordance with EN 50155 |
Yes |
Marine classification association |
|
● American Bureau of Shipping Europe Ltd. (ABS) |
Yes |
● Bureau Veritas (BV) |
Yes |
● Det Norske Veritas (DNV) |
Yes |
● Germanische Lloyd (GL) |
Yes |
● Lloyds Register of Shipping (LRS) |
Yes |
● Nippon Kaiji Kyokai (NK) |
Yes |
● Polski Rejestr Statkow (PRS) |
No |
● Royal Institution of Naval Architects (RINA) |
No |
MTBF / at 40 °C |
61.64 y |
Further Information / Internet Links |
Internet-Link |
|
● to website: Selector SIMATIC NET SELECTION TOOL |
http://www.siemens.com/snst |
● to website: Industrial communication |
http://www.siemens.com/simatic-net |
● to website: Information and Download Center |
http://www.siemens.com/automation/net/catalog |
● to website: Image database |
http://automation.siemens.com/bilddb |
● to website: CAx Download Manager |
http://www.siemens.com/cax |
● to website: Industry Online Support |
http://support.automation.siemens.com |
Security information |
Security information |
Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4) |
last modified: |
23.10.2014 |
Date 03.11.2014 |
Changes preserved © Copyright Siemens AG 2014 |