 |
|
General information |
Hardware product version |
01 |
Firmware version |
V2.3.3 |
Engineering with |
● Programming package |
STEP 7 V5.3 SP3 |
Supply voltage |
Rated value (DC) |
24 V |
24 V DC |
Yes |
permissible range, lower limit (DC) |
20.4 V |
permissible range, upper limit (DC) |
28.8 V |
external protection for power supply lines (recommendation) |
2 A min. |
Input current |
Current consumption (in no-load operation), typ. |
100 mA |
Rated value at 24 V DC |
100 mA; idling |
Inrush current, max. |
2.5 A; Typical |
Inrush current, typ. |
2.5 A |
I²t |
1 A²·s |
Power loss |
Power loss, typ. |
3.5 W |
Memory |
Work memory |
● integrated |
192 kbyte |
● expandable |
No |
Load memory |
● Plug-in (MMC) |
Yes |
● Plug-in (MMC), max. |
8 Mbyte |
● Data management on MMC (after last programming), min. |
10 y |
● expandable FEPROM |
can be plugged in as MMC |
Backup |
● present |
Yes; maintenance-free |
CPU processing times |
for bit operations, typ. |
0.1 µs |
for bit operations, max. |
0.1 µs |
for word operations, typ. |
0.2 µs |
for fixed point arithmetic, typ. |
2 µs |
CPU-blocks |
Number of blocks (total) |
1 024 |
DB |
● Number, max. |
1 023; From DB 1 to DB 1023 |
● Size, max. |
16 kbyte |
FB |
● Number, max. |
2 048; from FB 0 to FB 2047 |
● Size, max. |
16 kbyte |
FC |
● Number, max. |
2 048; from FC 0 to FC 2047 |
● Size, max. |
16 kbyte |
OB |
● Number, max. |
see instruction list |
● Size, max. |
16 kbyte |
● Number of free cycle OBs |
1; OB 1 |
● Number of time alarm OBs |
1; OB 10 |
● Number of delay alarm OBs |
1; OB 20 |
● Number of time interrupt OBs |
1; OB 35 |
● Number of process alarm OBs |
1; OB 40 |
● Number of startup OBs |
1; OB 100 |
● Number of asynchronous error OBs |
1; OB 80 |
● Number of synchronous error OBs |
2; OB 121, 122 |
Nesting depth |
● per priority class |
8 |
● additional within an error OB |
4 |
Counters, timers and their retentivity |
S7 counter |
● Number |
256 |
of which retentive without battery |
— adjustable |
Yes |
— preset |
Z 0 to Z 7 |
Retentivity |
— adjustable |
Yes |
Counting range |
— adjustable |
Yes |
— lower limit |
0 |
— upper limit |
999 |
IEC counter |
● present |
Yes |
● Type |
SFB |
● Number |
Unlimited (limited only by RAM capacity) |
S7 times |
● Number |
256 |
Retentivity |
— adjustable |
Yes |
— preset |
No retentivity |
Time range |
— lower limit |
10 ms |
— upper limit |
9 990 s |
IEC timer |
● present |
Yes |
● Type |
SFB |
● Number |
Unlimited (limited only by RAM capacity) |
Data areas and their retentivity |
retentive data area, total |
up to 128 KB |
Flag |
● Number, max. |
2 048 byte |
● Retentivity available |
Yes; MB 0 to MB 2047 |
● Retentivity preset |
MB 0 to MB 15 |
● Number of clock memories |
8; 1 memory byte |
Data blocks |
● Number, max. |
1 023; from DB 1 to DB 1024 |
● Size, max. |
16 kbyte |
Local data |
● per priority class, max. |
1 024 byte; max. 510 bytes per block |
Address area |
I/O address area |
● Inputs |
2 048 byte |
● Outputs |
2 048 byte |
of which distributed |
— Inputs |
2 kbyte |
— Outputs |
2 kbyte |
Process image |
● Inputs |
384 byte |
● Outputs |
384 byte |
Digital channels |
● Inputs |
16 384 |
● Outputs |
16 384 |
● Inputs, of which central |
1 024; max. |
● Outputs, of which central |
1 024; max. |
Analog channels |
● Inputs |
1 024 |
● Outputs |
1 024 |
● Inputs, of which central |
256 |
● Outputs, of which central |
256 |
Hardware configuration |
Number of DP masters |
● integrated |
1 |
● via CP |
4 |
Number of operable FMs and CPs (recommended) |
● FM |
8 |
● CP, point-to-point |
8 |
● CP, LAN |
10 |
Rack |
● Racks, max. |
4 |
● Modules per rack, max. |
8 |
Time of day |
Clock |
● Hardware clock (real-time clock) |
Yes |
● battery-backed and synchronizable |
Yes |
● Deviation per day, max. |
10 s |
● Backup time |
6 wk; At 40 °C ambient temperature |
Operating hours counter |
● Number |
1 |
● Range of values |
0 to 2^31 hours (when using SFC 101) |
● Granularity |
1 hour |
● retentive |
Yes; Must be restarted at each restart |
Clock synchronization |
● supported |
Yes |
● to MPI, master |
Yes |
● to MPI, slave |
Yes |
● in AS, master |
Yes |
● in AS, slave |
Yes |
1. Interface |
Interface type |
Integrated RS 485 interface |
Physics |
RS 485 |
isolated |
Yes |
Power supply to interface (15 to 30 V DC), max. |
200 mA |
Functionality |
● MPI |
Yes |
● DP master |
Yes |
● DP slave |
Yes |
● Point-to-point connection |
No |
MPI |
● Number of connections |
16 |
● Transmission rate, max. |
12 Mbit/s |
Services |
— PG/OP communication |
Yes |
— Routing |
Yes |
— Global data communication |
Yes |
— S7 basic communication |
Yes |
— S7 communication |
Yes |
— S7 communication, as client |
No |
— S7 communication, as server |
Yes |
DP master |
● Transmission rate, max. |
12 Mbit/s |
● Number of DP slaves, max. |
124 |
Services |
— PG/OP communication |
Yes |
— Routing |
Yes |
— Global data communication |
No |
— S7 basic communication |
Yes |
— S7 communication |
Yes |
— S7 communication, as client |
No |
— S7 communication, as server |
Yes |
— Equidistance mode support |
Yes |
— SYNC/FREEZE |
Yes |
— DPV1 |
Yes |
DP slave |
● Transmission rate, max. |
12 Mbit/s |
● Address area, max. |
32; With max. 32 bytes each |
Services |
— Routing |
Yes; Only with active interface |
— Global data communication |
No |
— S7 basic communication |
Yes |
— S7 communication |
Yes |
— S7 communication, as client |
No |
— S7 communication, as server |
Yes |
— Direct data exchange (slave-to-slave communication) |
Yes |
— DPV1 |
No |
Transfer memory |
— Inputs |
244 byte |
— Outputs |
244 byte |
2. Interface |
Interface type |
PROFINET |
Physics |
Ethernet |
isolated |
Yes |
Power supply to interface (15 to 30 V DC), max. |
0 mA |
automatic detection of transmission rate |
Yes; 10/100 Mbit/s |
Functionality |
● MPI |
No |
● DP master |
No |
● DP slave |
No |
● PROFINET IO Controller |
Yes |
● PROFINET CBA |
Yes |
● Point-to-point connection |
No |
PROFINET IO Controller |
● Transmission rate, max. |
100 Mbit/s |
● Number of connectable IO Devices, max. |
128 |
● Updating time |
1 to 512 ms (minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the volume of configured user data) |
Services |
— PG/OP communication |
Yes |
— Routing |
Yes |
— S7 communication |
Yes; with loadable FBs, max. configurable connections: 16 |
— Open IE communication |
Yes; via TCP/IP |
Address area |
— Inputs, max. |
2 kbyte |
— Outputs, max. |
2 kbyte |
— User data consistency, max. |
256 byte |
PROFINET CBA |
● acyclic transmission |
Yes |
● cyclic transmission |
Yes |
Communication functions |
PG/OP communication |
Yes |
Global data communication |
● supported |
Yes |
● Number of GD loops, max. |
8 |
● Number of GD packets, max. |
8 |
● Number of GD packets, transmitter, max. |
8 |
● Number of GD packets, receiver, max. |
8 |
● Size of GD packets, max. |
22 byte |
● Size of GD packet (of which consistent), max. |
22 byte |
S7 basic communication |
● supported |
Yes |
● User data per job, max. |
76 byte |
● User data per job (of which consistent), max. |
76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
S7 communication |
● supported |
Yes |
● as server |
Yes |
● as client |
Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB |
S5 compatible communication |
● supported |
Yes; Via CP and loadable FB |
Open IE communication |
● TCP/IP |
Yes; via integrated PROFINET interface and loadable FBs |
— Number of connections, max. |
8 |
— Data length, max. |
1 460 byte |
PROFINET CBA (at set setpoint communication load) |
● Setpoint for the CPU communication load |
50 % |
● Number of remote interconnection partners |
32 |
● Number of functions, master/slave |
17 |
● Total of all master/slave connections |
1 000 |
● Data length of all incoming connections master/slave, max. |
4 000 byte |
● Data length of all outgoing connections master/slave, max. |
4 000 byte |
● Number of device-internal and PROFIBUS interconnections |
500 |
● Data length of device-internal und PROFIBUS interconnections, max. |
4 000 byte |
● Data length per connection, max. |
1 400 byte |
Remote interconnections with acyclic transmission |
— Sampling frequency: Sampling time, min. |
500 ms |
— Number of incoming interconnections |
100 |
— Number of outgoing interconnections |
100 |
— Data length of all incoming interconnections, max. |
2 000 byte |
— Data length of all outgoing interconnections, max. |
2 000 byte |
— Data length per connection, max. |
1 400 byte |
Remote interconnections with cyclic transmission |
— Transmission frequency: Transmission interval, min. |
10 ms |
— Number of incoming interconnections |
200 |
— Number of outgoing interconnections |
200 |
— Data length of all incoming interconnections, max. |
2 000 byte |
— Data length of all outgoing interconnections, max. |
2 000 byte |
— Data length per connection, max. |
450 byte |
HMI variables via PROFINET (acyclic) |
— Number of stations that can log on for HMI variables (PN OPC/iMap) |
3; 2x PN OPC/1x iMap |
— HMI variable updating |
500 ms |
— Number of HMI variables |
200 |
— Data length of all HMI variables, max. |
2 000 byte |
PROFIBUS proxy functionality |
— supported |
Yes |
— Number of linked PROFIBUS devices |
16 |
— Data length per connection, max. |
240 byte; Slave-dependent |
Number of connections |
● overall |
16 |
● usable for PG communication |
15; max. |
— reserved for PG communication |
1 |
— adjustable for PG communication, min. |
1 |
— adjustable for PG communication, max. |
15; 1 to 15 |
● usable for OP communication |
15 |
— reserved for OP communication |
1 |
— adjustable for OP communication, min. |
1 |
— adjustable for OP communication, max. |
15; 1 to 15 |
● usable for S7 basic communication |
14 |
— reserved for S7 basic communication |
0 |
— adjustable for S7 basic communication, min. |
0 |
— adjustable for S7 basic communication, max. |
14; 0 to 14 |
S7 message functions |
Number of login stations for message functions, max. |
16; Depending on the configured connections for PG/OP and S7 basic communication |
Process diagnostic messages |
Yes |
simultaneously active Alarm-S blocks, max. |
40 |
Test commissioning functions |
Status block |
Yes |
Single step |
Yes |
Number of breakpoints |
2 |
Status/control |
● Status/control variable |
Yes |
● Variables |
Inputs, outputs, memory bits, DB, times, counters |
● Number of variables, max. |
30 |
● of which status variables, max. |
30 |
● of which control variables, max. |
14 |
Forcing |
● Forcing |
Yes |
● Forcing, variables |
Inputs, outputs |
● Number of variables, max. |
10 |
Diagnostic buffer |
● present |
Yes |
● Number of entries, max. |
100 |
— adjustable |
No |
Configuration |
Configuration software |
● STEP 7 |
Yes; with HSP88, otherwise with SP3 |
Programming |
● Command set |
see instruction list |
● Nesting levels |
8 |
● System functions (SFC) |
see instruction list |
● System function blocks (SFB) |
see instruction list |
Programming language |
— LAD |
Yes |
— FBD |
Yes |
— STL |
Yes |
— SCL |
Yes |
— CFC |
Yes |
— GRAPH |
Yes |
— HiGraph® |
Yes |
Know-how protection |
● User program protection/password protection |
Yes |
Dimensions |
Width |
80 mm |
Height |
125 mm |
Depth |
130 mm |
last modified: |
31.07.2014 |