Supply voltage |
24 V DC |
Yes |
permissible range, lower limit (DC) |
20.4 V |
permissible range, upper limit (DC) |
28.8 V |
Load voltage L+ |
● Rated value (DC) |
24 V |
● Reverse polarity protection |
Yes |
Digital outputs |
Load voltage L+ |
— Rated value (DC) |
24 V |
— Reverse polarity protection |
No |
Input current |
Current consumption (in no-load operation), typ. |
200 mA |
Inrush current, typ. |
2.5 A |
I²t |
1 A²·s |
Power losses |
Power loss, typ. |
6 W |
Memory |
Work memory |
● Integrated |
256 kbyte |
● expandable |
No |
Load memory |
● pluggable (MMC) |
Yes |
● pluggable (MMC), max. |
8 Mbyte |
● Data management on MMC (after last programming), min. |
10 y |
Backup |
● present |
Yes |
● without battery |
Yes |
CPU processing times |
for bit operations, typ. |
0.1 µs |
for bit operations, max. |
0.1 µs |
for word operations, typ. |
0.2 µs |
for fixed point arithmetic, typ. |
2 µs |
for floating point arithmetic, typ. |
3 µs |
CPU-blocks |
Number of blocks (total) |
1 024 |
DB |
● Number, max. |
1 023 |
● Size, max. |
64 kbyte |
FB |
● Number, max. |
1 024 |
● Size, max. |
64 kbyte |
FC |
● Number, max. |
1 024 |
● Size, max. |
64 kbyte |
OB |
● Size, max. |
64 kbyte |
● Number of free cycle OBs |
1 |
● Number of time alarm OBs |
1 |
● Number of delay alarm OBs |
1 |
● Number of time interrupt OBs |
1 |
● Number of process alarm OBs |
1 |
● Number of DPV1 alarm OBs |
3 |
● Number isochronous mode OBs |
1 |
● Number of technology synchronous alarm OBs |
1 |
● Number of startup OBs |
1 |
● Number of asynchronous error OBs |
5 |
● Number of synchronous error OBs |
2 |
Nesting depth |
● per priority class |
8 |
● additional within an error OB |
4 |
Counters, timers and their retentivity |
S7 counter |
● Number |
256 |
Retentivity |
— can be set |
Yes |
Counting range |
— can be set |
Yes |
— lower limit |
0 |
— upper limit |
999 |
IEC counter |
● present |
Yes |
S7 times |
● Number |
256 |
of which retentive without battery |
— can be set |
Yes |
Retentivity |
— can be set |
Yes |
Time range |
— lower limit |
10 ms |
— upper limit |
9 990 s |
IEC timer |
● present |
Yes |
Data areas and their retentivity |
Flag |
● Number, max. |
2 048 byte |
● Retentivity available |
Yes |
● Number of clock memories |
8 |
Data blocks |
● Number, max. |
1 023 |
● Size, max. |
64 kbyte |
● Retentivity adjustable |
Yes |
Local data |
● per priority class, max. |
1 024 byte |
Address area |
I/O address area |
● Inputs |
2 048 byte |
● Outputs |
2 048 byte |
of which, distributed |
— Inputs |
2 048 byte |
— Outputs |
2 048 byte |
Process image |
● Inputs, adjustable |
2 048 byte |
● Outputs, adjustable |
2 048 byte |
● Inputs, default |
128 byte |
● Outputs, default |
128 byte |
Subprocess images |
● Number of subprocess images, max. |
1 |
Digital channels |
● Inputs |
16 384 |
● Outputs |
16 384 |
● Inputs, of which central |
512 |
● Outputs, of which central |
512 |
Analog channels |
● Inputs |
1 024 |
● Outputs |
1 024 |
● Inputs, of which central |
64 |
● Outputs, of which central |
64 |
Hardware configuration |
Expansion devices, max. |
0 |
Number of DP masters |
● Integrated |
2 |
● Via CP |
2 |
Number of operable FMs and CPs (recommended) |
● FM |
8 |
● CP, point-to-point |
8 |
● CP, LAN |
10 |
Rack |
● Racks, max. |
1 |
● Modules per rack, max. |
8 |
Time of day |
Clock |
● Hardware clock (real-time clock) |
Yes |
● battery-backed and synchronizable |
Yes |
● Deviation per day, max. |
10 s |
● Backup time |
6 wk |
Operating hours counter |
● Number |
1 |
● retentive |
Yes |
Clock synchronization |
● supported |
Yes |
● to MPI, master |
Yes |
● to MPI, slave |
Yes |
● to DP, master |
Yes |
● to DP, slave |
Yes |
● in AS, master |
Yes |
● in AS, slave |
Yes |
Digital inputs |
Number of digital inputs |
4 |
● of which, inputs usable for technological functions |
4 |
Input characteristic curve in accordance with IEC 61131, type 1 |
Yes |
Number of simultaneously controllable inputs |
horizontal installation |
— up to 40 °C, max. |
4 |
— up to 60 °C, max. |
4 |
vertical installation |
— up to 40 °C, max. |
4 |
Input voltage |
● Rated value, DC |
24 V |
Input current |
● for signal "1", typ. |
7 mA |
Input delay (for rated value of input voltage) |
for counter/technological functions |
— at "0" to "1", max. |
10 µs |
— at "1" to "0", max. |
10 µs |
Cable length |
● Cable length, shielded, max. |
1 000 m |
Digital outputs |
Number of digital outputs |
8 |
● of which high-speed outputs |
8 |
short-circuit protection |
Yes |
Controlling a digital input |
No |
Switching capacity of the outputs |
● Lamp load, max. |
5 W |
Load resistance range |
● lower limit |
48 Ω |
● upper limit |
4 kΩ |
Output voltage |
● for signal "0", max. |
3 V |
Output current |
● for signal "1" rated value |
0.5 A |
● for signal "1" permissible range for 0 to 60 °C, min. |
5 mA |
● for signal "1" permissible range for 0 to 60 °C, max. |
0.6 A |
● for signal "0" residual current, max. |
0.3 mA |
Parallel switching of 2 outputs |
● for increased power |
No |
● for redundant control of a load |
No |
Switching frequency |
● with resistive load, max. |
100 Hz |
● with inductive load, max. |
0.2 Hz |
● on lamp load, max. |
100 Hz |
Aggregate current of outputs (per group) |
horizontal installation |
— up to 40 °C, max. |
4 A |
— up to 60 °C, max. |
3 A |
all other mounting positions |
— up to 40 °C, max. |
3 A |
Cable length |
● Cable length, shielded, max. |
1 000 m |
Analog inputs |
Number of analog inputs |
0 |
Analog outputs |
Number of analog outputs |
0 |
Encoder |
Connectable encoders |
● 2-wire sensor |
No |
Interfaces |
Number of RS 422 interfaces |
0 |
Number of other interfaces |
0 |
1st interface |
Isolated |
Yes |
Power supply to interface (15 to 30 V DC), max. |
200 mA |
Functionality |
● MPI |
Yes |
● DP master |
Yes |
● DP slave |
Yes |
● Point-to-point connection |
No |
MPI |
● Number of connections |
32 |
● Transmission rate, max. |
12 Mbit/s |
Services |
— PG/OP communication |
Yes |
— Routing |
Yes |
— Global data communication |
Yes |
— S7 basic communication |
Yes |
— S7 communication |
Yes |
— S7 communication, as client |
No |
— S7 communication, as server |
Yes |
DP master |
● Transmission rate, max. |
12 Mbit/s |
● Number of DP slaves, max. |
124 |
Services |
— PG/OP communication |
Yes |
— Routing |
Yes |
— Global data communication |
No |
— S7 basic communication |
Yes |
— S7 communication |
Yes |
— S7 communication, as client |
No |
— S7 communication, as server |
Yes |
— Equidistance mode support |
Yes |
— Isochronous mode |
Yes |
— SYNC/FREEZE |
Yes |
— Activation/deactivation of DP slaves |
Yes |
— DPV1 |
Yes |
Address area |
— Inputs, max. |
2 048 byte |
— Outputs, max. |
2 048 byte |
User data per DP slave |
— Inputs, max. |
244 byte |
— Outputs, max. |
244 byte |
DP slave |
● Transmission rate, max. |
12 Mbit/s |
● Automatic baud rate search |
No |
● Address area, max. |
32 |
● User data per address area, max. |
32 byte |
Services |
— PG/OP communication |
Yes |
— Routing |
Yes |
— Global data communication |
No |
— S7 basic communication |
No |
— S7 communication |
Yes |
— S7 communication, as client |
No |
— S7 communication, as server |
Yes |
— Direct data exchange (slave-to-slave communication) |
Yes |
— DPV1 |
No |
Transfer memory |
— Inputs |
244 byte |
— Outputs |
244 byte |
2nd interface |
Isolated |
Yes |
Power supply to interface (15 to 30 V DC), max. |
200 mA |
Functionality |
● MPI |
No |
● DP master |
Yes |
● DP slave |
No |
● Point-to-point connection |
No |
DP master |
● Transmission rate, max. |
12 Mbit/s |
● Number of DP slaves, max. |
64 |
Services |
— PG/OP communication |
No |
— Routing |
No |
— Global data communication |
No |
— S7 basic communication |
No |
— S7 communication |
No |
— Equidistance mode support |
Yes |
— Isochronous mode |
Yes |
— SYNC/FREEZE |
No |
— Activation/deactivation of DP slaves |
Yes |
— DPV1 |
No |
Address area |
— Inputs, max. |
1 024 byte |
— Outputs, max. |
1 024 byte |
User data per DP slave |
— Inputs, max. |
244 byte |
— Outputs, max. |
244 byte |
DP slave |
● Transmission rate, max. |
12 Mbit/s |
Communication functions |
PG/OP communication |
Yes |
Global data communication |
● supported |
Yes |
● Number of GD loops, max. |
8 |
● Number of GD packets, max. |
8 |
● Number of GD packets, transmitter, max. |
8 |
● Number of GD packets, receiver, max. |
8 |
● Size of GD packets, max. |
22 byte |
● Size of GD packet (of which consistent), max. |
22 byte |
S7 basic communication |
● supported |
Yes |
● User data per job, max. |
76 byte |
● User data per job (of which consistent), max. |
76 byte |
S7 communication |
● supported |
Yes |
● as server |
Yes |
● As client |
Yes |
S5-compatible communication |
● supported |
Yes |
Number of connections |
● overall |
16 |
● usable for PG communication |
15 |
— reserved for PG communication |
1 |
— Adjustable for PG communication, min. |
1 |
— Adjustable for PG communication, max. |
15 |
● usable for OP communication |
15 |
— reserved for OP communication |
1 |
— adjustable for OP communication, min. |
1 |
— adjustable for OP communication, max. |
15 |
● usable for S7 basic communication |
12 |
— Reserved for S7 basic communication |
0 |
— adjustable for S7 basic communication, min. |
0 |
— adjustable for S7 basic communication, max. |
12 |
● usable for routing |
8 |
S7 message functions |
Number of login stations for message functions, max. |
16 |
Process diagnostic messages |
Yes |
simultaneously active Alarm-S blocks, max. |
40 |
Test commissioning functions |
Status block |
Yes |
Single step |
Yes |
Number of breakpoints |
2 |
Status/control |
● Status/control variable |
Yes |
● Number of variables, max. |
30 |
● of which status variables, max. |
30 |
● of which control variables, max. |
14 |
Forcing |
● Forcing |
Yes |
● Number of variables, max. |
10 |
Diagnostic buffer |
● present |
Yes |
● Number of entries, max. |
100 |
— can be set |
No |
Interrupts/diagnostics/status information |
Alarms |
● Alarms |
No |
Diagnostic messages |
● Diagnostic functions |
No |
Diagnostics indication LED |
● Status indicator digital output (green) |
Yes |
● Status indicator digital input (green) |
Yes |
Galvanic isolation |
Galvanic isolation digital inputs |
● between the channels and the backplane bus |
Yes |
Galvanic isolation digital outputs |
● between the channels and the backplane bus |
Yes |
Ambient conditions |
Operating temperature |
● Min. |
0 °C |
● max. |
60 °C |
Configuration |
Configuration software |
● STEP 7 |
Yes |
programming |
● Nesting levels |
8 |
Programming language |
— LAD |
Yes |
— FBD |
Yes |
— STL |
Yes |
— SCL |
Yes |
— CFC |
Yes |
— GRAPH |
Yes |
— HiGraph® |
Yes |
Know-how protection |
● User program protection/password protection |
Yes |
Cycle time monitoring |
● lower limit |
1 ms |
● upper limit |
6 000 ms |
● can be set |
Yes |
● preset |
150 ms |
Dimensions |
Width |
160 mm |
Height |
125 mm |
Depth |
130 mm |
Weights |
Weight, approx. |
750 g |
last modified: |
16.09.2014 |