6ES7317-2EK13-0AB0 CPU317-2 PN/DP, 1 MB

Product Code: 6ES7317-2EK13-0AB0

Availability: In Stock

Price: $2,261.87
  
 
Artikelnummer 6ES7317-2EK13-0AB0
SIMATIC S7-300 CPU 317-2 PN/DP, CENTRAL PROCESSING UNIT WITH 1 MB WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, MICRO MEMORY CARD NECESSARY
General information
Hardware product version 01
Firmware version V2.6
Engineering with
● Programming package STEP 7 V5.4 SP2
Supply voltage
24 V DC Yes
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
External protection for supply cables (recommendation) 2 A min.
Input current
Current consumption (rated value) 650 mA
Current consumption (in no-load operation), typ. 100 mA
Inrush current, typ. 2.5 A
I²t 1 A²·s
Power losses
Power loss, typ. 3.5 W
Memory
Type of memory other
Work memory
● Integrated 1 Mbyte; For program and data
● expandable No
● Size of retentive memory for retentive data blocks 256 kbyte
Load memory
● pluggable (MMC) Yes
● pluggable (MMC), max. 8 Mbyte
● Data management on MMC (after last programming), min. 10 y
Backup
● present Yes; Guaranteed by MMC (maintenance-free)
● without battery Yes; Program and data
CPU processing times
for bit operations, typ. 0.05 µs
for word operations, typ. 0.2 µs
for fixed point arithmetic, typ. 0.2 µs
for floating point arithmetic, typ. 1 µs
CPU-blocks
Number of blocks (total) 2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
● Number, max. 2 047; Number band: 1 to 2047
● Size, max. 64 kbyte
FB
● Number, max. 2 048; Number range: 0 to 2047
● Size, max. 64 kbyte
FC
● Number, max. 2 048; Number range: 0 to 2047
● Size, max. 64 kbyte
OB
● Size, max. 64 kbyte
● Number of free cycle OBs 1; OB 1
● Number of time alarm OBs 1; OB 10
● Number of delay alarm OBs 2; OB 20, 21
● Number of time interrupt OBs 4; OB 32, 33, 34, 35
● Number of process alarm OBs 1; OB 40
● Number of DPV1 alarm OBs 3; OB 55, 56, 57
● Number isochronous mode OBs 1; OB 61
● Number of startup OBs 1; OB 100
● Number of asynchronous error OBs 6; OB 80, 82, 83, 85, 86, 87
● Number of synchronous error OBs 2; OB 121, 122
Nesting depth
● per priority class 16
● additional within an error OB 4
Counters, timers and their retentivity
S7 counter
● Number 512
Retentivity
— can be set Yes
— lower limit 0
— upper limit 511
— preset Z 0 to Z 7
Counting range
— can be set Yes
— lower limit 0
— upper limit 999
IEC counter
● present Yes
● Type SFB
● Number Unlimited (limited only by RAM capacity)
S7 times
● Number 512
Retentivity
— can be set Yes
— lower limit 0
— upper limit 511
— preset No retentivity
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
● Type SFB
● Number Unlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area, total All, max. 256 KB
Flag
● Number, max. 4 096 byte
● Retentivity available Yes; From MB 0 to MB 4095
● Retentivity preset MB 0 to MB 15
● Number of clock memories 8; 1 memory byte
Data blocks
● Number, max. 2 047; Number band: 1 to 2047
● Size, max. 64 kbyte
● Retentivity adjustable Yes; via non-retain property on DB
● Retentivity preset Yes
Local data
● per priority class, max. 1 024 byte
Address area
I/O address area
● Inputs 8 192 byte
● Outputs 8 192 byte
of which, distributed
— Inputs 8 192 byte
— Outputs 8 192 byte
Process image
● Inputs 2 048 byte
● Outputs 2 048 byte
● Inputs, adjustable 2 048 byte
● Outputs, adjustable 2 048 byte
● Inputs, default 256 byte
● Outputs, default 256 byte
Subprocess images
● Number of subprocess images, max. 1
Digital channels
● Inputs 65 536
● Outputs 65 536
● Inputs, of which central 1 024
● Outputs, of which central 1 024
Analog channels
● Inputs 4 096
● Outputs 4 096
● Inputs, of which central 256
● Outputs, of which central 256
Hardware configuration
Expansion devices, max. 3
Number of DP masters
● Integrated 1
● Via CP 4
Number of operable FMs and CPs (recommended)
● FM 8
● CP, point-to-point 8
● CP, LAN 10
Rack
● Racks, max. 4
● Modules per rack, max. 8
Time of day
Clock
● Hardware clock (real-time clock) Yes
● battery-backed and synchronizable Yes
● Deviation per day, max. 10 s
● Backup time 6 wk; At 40 °C ambient temperature
● Behavior of the clock following POWER-ON Clock continues running after POWER OFF
● Behavior of the clock following expiry of backup period Clock continues to run with the time at which the power failure occurred
Operating hours counter
● Number 4
● Number/Number range 0 to 3
● Range of values 0 to 2^31 hours (when using SFC 101)
● Granularity 1 hour
● retentive Yes; Must be restarted at each restart
Clock synchronization
● supported Yes
● to MPI, master Yes
● to MPI, slave Yes
● to DP, master Yes; With DP slave only slave clock
● to DP, slave Yes
● in AS, master Yes
● in AS, slave Yes
● on Ethernet via NTP Yes; As client
Digital inputs
integrated channels (DI) 0
Digital outputs
integrated channels (DO) 0
Analog inputs
Integrated channels (AI) 0
Analog outputs
Integrated channels (AO) 0
Interfaces
Number of parallel interfaces 0
Number of 20 mA interfaces (TTY) 0
Number of RS 232 interfaces 0
Number of RS 422 interfaces 0
Number of other interfaces 0
1st interface
Interface type Integrated RS 485 interface
Physics RS 485
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 200 mA
Functionality
● MPI Yes
● DP master Yes
● DP slave Yes
● Point-to-point connection No
MPI
● Number of connections 32
● Transmission rate, max. 12 Mbit/s
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication Yes
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
DP master
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 124
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication Yes; I blocks only
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
— Equidistance mode support Yes
— Isochronous mode Yes; OB 61
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Number of DP slaves that can be simultaneously activated/deactivated, max. 4
— DPV1 Yes
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
DP slave
● Transmission rate, max. 12 Mbit/s
● Automatic baud rate search Yes; only with passive interface
● Address area, max. 32
● User data per address area, max. 32 byte
Services
— PG/OP communication Yes
— Routing Yes; with interface active
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV1 No
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
2nd interface
Interface type PROFINET
Physics Ethernet RJ45
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 0 mA
Automatic detection of transmission speed Yes; 10/100 Mbit/s
Functionality
● MPI No
● DP master No
● DP slave No
● PROFINET IO Controller Yes
● PROFINET IO Device No
● PROFINET CBA Yes
● Open IE communication Yes; Via TCP/IP, ISO on TCP, and UDP
● Web server Yes
● Point-to-point connection No
PROFINET IO Controller
● Transmission rate, max. 100 Mbit/s
● Number of connectable IO devices, max. 128
● Send cycles 1 ms
● Updating time 1 to 512 ms (minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the volume of configured user data)
Services
— PG/OP communication Yes
— Routing Yes
— S7 communication Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32
— Open IE communication Yes; Via TCP/IP, ISO on TCP, and UDP
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
— User data consistency, max. 254 byte
PROFINET CBA
● acyclic transmission Yes
● Cyclic transmission Yes
Communication functions
PG/OP communication Yes
Data record routing No
Global data communication
● supported Yes
● Number of GD loops, max. 8
● Number of GD packets, max. 8
● Number of GD packets, transmitter, max. 8
● Number of GD packets, receiver, max. 8
● Size of GD packets, max. 22 byte
● Size of GD packet (of which consistent), max. 22 byte
S7 basic communication
● supported Yes
● User data per job, max. 76 byte
● User data per job (of which consistent), max. 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
● supported Yes
● as server Yes
● As client Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
● User data per job, max. See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5-compatible communication
● supported Yes; via CP and loadable FC
Open IE communication
● TCP/IP Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 8
— Data length for connection type 01H, max. 1 460 byte
— Data length for connection type 11H, max. 8 192 byte
● ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 8
— Data length, max. 8 192 byte
● UDP Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 8
— Data length, max. 1 472 byte
Web server
● supported Yes; only read function
● Number of HTTP clients 5
PROFINET CBA (at set setpoint communication load)
● Setpoint for the CPU communication load 50 %
● Number of remote interconnection partners 32
● Number of functions, master/slave 30
● Total of all Master/Slave connections 1 000
● Data length of all incoming connections master/slave, max. 4 000 byte
● Data length of all outgoing connections master/slave, max. 4 000 byte
● Number of device-internal and PROFIBUS interconnections 500
● Data length of device-internal und PROFIBUS interconnections, max. 4 000 byte
● Data length per connection, max. 1 400 byte
Remote interconnections with acyclic transmission
— Sampling frequency: Sampling time, min. 500 ms
— Number of incoming interconnections 100
— Number of outgoing interconnections 100
— Data length of all incoming interconnections, max. 2 000 byte
— Data length of all outgoing interconnections, max. 2 000 byte
— Data length per connection, max. 1 400 byte
Remote interconnections with cyclic transmission
— Transmission frequency: Transmission interval, min. 10 ms
— Number of incoming interconnections 200
— Number of outgoing interconnections 200
— Data length of all incoming interconnections, max. 2 000 byte
— Data length of all outgoing interconnections, max. 2 000 byte
— Data length per connection, max. 450 byte
HMI variables via PROFINET (acyclic)
— Number of stations that can log on for HMI variables (PN OPC/iMap) 3; 2x PN OPC/1x iMap
— HMI variable updating 500 ms
— Number of HMI variables 200
— Data length of all HMI variables, max. 2 000 byte
PROFIBUS proxy functionality
— supported Yes
— Number of linked PROFIBUS devices 16
— Data length per connection, max. 240 byte; Slave-dependent
Number of connections
● overall 32
● usable for PG communication 31
— reserved for PG communication 1
— Adjustable for PG communication, min. 1
— Adjustable for PG communication, max. 31
● usable for OP communication 31
— reserved for OP communication 1
— adjustable for OP communication, min. 1
— adjustable for OP communication, max. 31
● usable for S7 basic communication 30
— Reserved for S7 basic communication 0
— adjustable for S7 basic communication, min. 0
— adjustable for S7 basic communication, max. 30
● usable for S7 communication 16
— reserved for S7 communication 0
— Adjustable for S7 communication, min. 0
— Adjustable for S7 communication, max. 16
● Max. total number of instances 32
● usable for routing X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.
S7 message functions
Number of login stations for message functions, max. 32; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messages Yes
simultaneously active Alarm-S blocks, max. 60
Test commissioning functions
Status block Yes
Single step Yes
Number of breakpoints 2
Status/control
● Status/control variable Yes
● Variables Inputs, outputs, memory bits, DB, times, counters
● Number of variables, max. 30
● of which status variables, max. 30
● of which control variables, max. 14
Forcing
● Forcing Yes
● Force, variables Inputs, outputs
● Number of variables, max. 10
Diagnostic buffer
● present Yes
● Number of entries, max. 500
— can be set No
— Of which powerfail-proof 100
Configuration
Configuration software
● STEP 7 Yes; V5.4 SP2 or higher
programming
● Command set see instruction list
● Nesting levels 8
● System functions (SFC) see instruction list
● System function blocks (SFB) see instruction list
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Know-how protection
● User program protection/password protection Yes
Dimensions
Width 80 mm
Height 125 mm
Depth 130 mm
Weights
Weight, approx. 460 g
last modified: 25.09.2014