SIMATIC S7-MODULAR EMBEDDED CONTROLLER, EC31-HMI/RTX, 1 GB RAM, 2 GB FLASH DISK WITH PREINSTALLED SW: WINDOWS XP EMBEDDED; SIMATIC WINAC RTX, SIMATIC SOFTNET-S7/ LEAN, WINCC FLEXIBLE RT 2048 PT, (INCL. SMART ACCESS, ARCHIVES AND RECIPES), INTERFACES: 1. IF: 2 X PROFINET, 2. IF: 1 X FAST ETHERNET, 3. IF: 2 X USB, MMC SLOT, DOCUMENTATION ON CD/DVD, RESTORE CD/DVD |
General information |
Hardware product version |
04 |
Firmware version |
V1.3 |
PC configuration |
Computer platform |
SIMATIC S7 modular embedded controller |
Processor selection |
Intel Core Duo 1.2 GHz |
Main memory |
1 GB RAM |
Flash Disk |
2 Gbyte |
Operating systems |
Windows XP embedded SP2 FP2007 |
Installed software |
● Visualization |
WinCC flexible RT 2008 |
● Control |
SIMATIC WinAC RTX 2009 |
● Communication |
Yes |
Supply voltage |
Rated value, 24 V DC |
Yes |
permissible range, lower limit (DC) |
20.4 V |
permissible range, upper limit (DC) |
28.8 V |
Mains buffering |
● Mains/voltage failure stored energy time |
5 ms |
Input current |
Rated value at 24 V DC |
800 mA; without backplane bus and USB power supply |
Power losses |
Power loss, typ. |
34 W |
Memory |
Type of memory |
512 KB non-volatile memory for retentive data |
Work memory |
● Integrated |
1 Gbyte |
CPU processing times |
for bit operations, typ. |
0.004 µs; Typical |
for fixed point arithmetic, typ. |
0.003 µs; Typical |
for floating point arithmetic, typ. |
0.004 µs; Typical |
CPU-blocks |
DB |
● Number, max. |
Max. code size and max. data size: 4 MB each |
● Size, max. |
64 kbyte |
FB |
● Number, max. |
Max. code size and max. data size: 4 MB each |
● Size, max. |
64 kbyte |
FC |
● Number, max. |
Max. code size and max. data size: 4 MB each |
● Size, max. |
64 kbyte |
OB |
● Number, max. |
Max. code size and max. data size: 4 MB each |
● Size, max. |
64 kbyte |
● Number of free cycle OBs |
1; OB 1 |
● Number of time alarm OBs |
1; OB 10 |
● Number of delay alarm OBs |
1; OB 20 |
● Number of time interrupt OBs |
9; OB 30-38 |
● Number of process alarm OBs |
1; OB 40 |
● Number of startup OBs |
2; OB 100, 102 |
● Number of asynchronous error OBs |
7; OB 80, 82-85, 86, 88 |
● Number of synchronous error OBs |
2; OB 121, 122 |
Nesting depth |
● per priority class |
24 |
● additional within an error OB |
24 |
Counters, timers and their retentivity |
S7 counter |
● Number |
2 048 |
Retentivity |
— can be set |
Yes |
— lower limit |
0 |
— upper limit |
2 047 |
— preset |
8 |
Counting range |
— can be set |
Yes |
— lower limit |
0 |
— upper limit |
999 |
IEC counter |
● present |
Yes |
● Type |
SFB |
S7 times |
● Number |
2 048 |
Retentivity |
— can be set |
Yes |
— lower limit |
0 |
— upper limit |
2 047 |
Time range |
— lower limit |
10 ms |
— upper limit |
9 990 s |
IEC timer |
● present |
Yes |
● Type |
SFB |
Data areas and their retentivity |
retentive data area, total |
512 KB |
Flag |
● Number, max. |
16 kbyte |
● of which retentive without battery |
MB 0 to MB 16383 |
● Retentivity preset |
MB 0 to MB 15 |
● Number of clock memories |
8 |
Data blocks |
● Number, max. |
Max. code size and max. data size: 4 MB each |
● Size, max. |
64 kbyte |
Address area |
I/O address area |
● Inputs |
16 kbyte |
● Outputs |
16 kbyte |
of which, distributed |
— Inputs |
8 kbyte |
— Outputs |
8 kbyte |
Process image |
● Inputs, adjustable |
8 kbyte |
● Outputs, adjustable |
8 kbyte |
● Inputs, default |
512 byte |
● Outputs, default |
512 byte |
Subprocess images |
● Number of subprocess images, max. |
15 |
Digital channels |
● Inputs |
128 000 |
● Outputs |
128 000 |
Analog channels |
● Inputs |
8 000 |
● Outputs |
8 000 |
Hardware configuration |
Integrated power supply |
Yes |
Time of day |
Clock |
● Hardware clock (real-time clock) |
Yes; Resolution: 1 s |
Clock synchronization |
● supported |
Yes |
● to PC-CP, slave |
Yes |
● on Ethernet via NTP |
Yes |
Interfaces |
Number of USB interfaces |
2 |
USB port |
2 x USB 2.0 high speed/high current |
serial interface |
0 |
Industrial Ethernet |
● Industrial Ethernet interface |
X1: 2 ports 10/100 Mbit/s (ERTEC-based) X2: 1 port 10/100 Mbit/s |
1st interface |
Interface type |
PROFINET |
Physics |
2x RJ45 |
Automatic detection of transmission speed |
Yes |
Autonegotiation |
Yes |
Autocrossing |
Yes |
Number of connection resources |
32 |
Functionality |
● MPI |
No |
● DP master |
No |
● DP slave |
No |
● PROFINET IO Device |
No |
● PROFINET IO Controller |
Yes |
● PROFINET CBA |
Yes |
● Open IE communication |
Yes |
● Point-to-point connection |
No |
PROFINET IO Controller |
● Number of connectable IO devices, max. |
256 |
● Number of IO devices with IRT and the option "high flexibility" |
64 |
● IRT, supported |
Yes |
● Prioritized startup supported |
Yes |
— Number of IO Devices, max. |
32 |
● Activation/deactivation of IO Devices |
Yes |
— Maximum number of IO devices that can be activated/deactivated at the same time. |
8 |
● IO Devices changing during operation (partner ports), supported |
Yes |
— Max. number of IO devices per tool |
8 |
● Send cycles |
Adjustable: 250 µs, 500 µs and 1 ms |
● Updating times |
250 µs - 128 ms (with signal cycle 250 µs); 500 µs - 256 ms (with signal cycle 500 µs); 1 ms - 512 ms (with signal cycle 1 ms) |
Services |
— PG/OP communication |
Yes |
— S7 routing |
Yes |
— S7 communication |
Yes |
— Isochronous mode |
No |
Address area |
— Inputs, max. |
16 kbyte |
— Outputs, max. |
16 kbyte |
— User data per address area, max. |
2 kbyte |
— User data consistency, max. |
256 byte |
PROFINET CBA |
● acyclic transmission |
Yes |
● Cyclic transmission |
Yes |
Open IE communication |
● Open IE communication, supported |
Yes |
● Number of connections, max. |
32 |
● Local port numbers used at the system end |
0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 |
PROFINET functions |
● Detection of accessible nodes, supported |
Yes; DCP |
● Assignment of the IP address, supported |
Yes; DCP |
● Assignment of the device name, supported |
Yes; DCP |
● Topology recognition, supported |
Yes; LLDP, LLDP MIB, SNMP |
● Extended network diagnostics with Standard MIB II, supported |
Yes; Standard MIB II, SNMP |
2nd interface |
Interface type |
Integrated Ethernet interface |
Physics |
Ethernet RJ45 |
Automatic detection of transmission speed |
Yes |
Autonegotiation |
Yes |
Autocrossing |
No |
Number of connection resources |
32 |
Functionality |
● PROFINET IO Controller |
No |
● PROFINET IO Device |
No |
● PROFINET CBA |
No |
Communication functions |
PG/OP communication |
Yes |
Global data communication |
● supported |
No |
S7 basic communication |
● supported |
No |
S7 communication |
● supported |
Yes |
● as server |
Yes |
● As client |
Yes |
Open IE communication |
● TCP/IP |
Yes; Via integrated PROFINET interface (X1) and loadable FBs |
— Number of connections, max. |
32 |
— Data length, max. |
8 192 byte |
● ISO-on-TCP (RFC1006) |
No |
● UDP |
Yes; Via integrated PROFINET interface (X1) and loadable FBs |
— Number of connections, max. |
32 |
— Data length, max. |
1 472 byte |
Number of connections |
● overall |
64 |
● usable for PG communication |
|
— reserved for PG communication |
1 |
● usable for OP communication |
|
— reserved for OP communication |
1 |
S7 message functions |
Number of login stations for message functions, max. |
62; The alarm functions cannot currently be used for central bus modules |
Process diagnostic messages |
Yes; Alarm_S |
Test commissioning functions |
Status/control |
● Status/control variable |
Yes |
Forcing |
● Forcing |
No |
Diagnostic buffer |
● present |
Yes |
EMC |
Emission of radio interference acc. to EN 55 011 |
● Limit class A, for use in industrial areas |
Yes |
Degree and class of protection |
Degree of protection to EN 60529 |
|
● IP20 |
Yes |
Standards, approvals, certificates |
CE mark |
Yes |
CSA approval |
Yes; Included in cULus |
cULus |
Yes |
RCM (formerly C-TICK) |
Yes |
FM approval |
Yes |
Ambient conditions |
Operating temperature |
● Min. |
0 °C |
● max. |
50 °C |
Storage/transport temperature |
● Min. |
-40 °C |
● max. |
70 °C |
Vibrations |
● Operation, checked according to IEC 60068-2-6 |
Yes |
● Transport tested checked to IEC 60068-2-6 |
Yes |
Shock test |
● checked according to IEC 60068-2-27 |
Yes |
● checked according to IEC 60068-2-29 |
Yes |
Shock testing |
● checked according to IEC 60068-2-29 |
Yes |
● Operation, checked according to IEC 60068-2-29 |
Operation, tested according to IEC 60068-2-27 |
● Storage/transport, checked to IEC 60068-2-29 |
Yes |
Configuration |
Configuration software |
● STEP 7 |
Yes |
programming |
Programming language |
— LAD |
Yes |
— FBD |
Yes |
— STL |
Yes |
— SCL |
Yes |
— CFC |
Yes |
— GRAPH |
Yes |
— HiGraph® |
Yes |
Dimensions |
Width |
160 mm |
Height |
125 mm |
Depth |
115 mm |
last modified: |
14.10.2014 |