Fatal Error: Can't alloc dataspace in /www/wwwroot/www.kollewin.com/system/secache/secache.php on line 617
Warning: fopen(/www/wwwroot/www.kollewin.com/system/logs/error.txt): failed to open stream: Permission denied in /www/wwwroot/www.kollewin.com/system/library/log.php on line 12
Warning: fwrite() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 14
Warning: fclose() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 16
Warning: alloc datasize:976632435 in /www/wwwroot/www.kollewin.com/system/secache/secache.php on line 617
Warning: fopen(/www/wwwroot/www.kollewin.com/system/logs/error.txt): failed to open stream: Permission denied in /www/wwwroot/www.kollewin.com/system/library/log.php on line 12
Warning: fwrite() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 14
Warning: fclose() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 16
6ES7633-1DF02-0AE3 SIMATIC C7-633/P, COMPACT UNIT
Yes; 4736 Byte: parameterizable for memory bits, times, counters, data
CPU processing times
for bit operations, typ.
0.3 µs
for bit operations, max.
0.6 µs
for word operations, typ.
1 µs
for fixed point arithmetic, typ.
2 µs
for floating point arithmetic, typ.
50 µs
for timer/counter operations, typ.
12 µs
CPU-blocks
DB
● Number, max.
255; DB 0 reserved
FB
● Number, max.
192; see instruction list
FC
● Number, max.
192; see instruction list
OB
● Number, max.
see instruction list
● Number of free cycle OBs
1; OB 1
● Number of time alarm OBs
1; OB 10
● Number of time interrupt OBs
1; OB 35
● Number of process alarm OBs
1; OB 40
● Number of startup OBs
1; OB 100
● Number of asynchronous error OBs
7; OB 80, 81, 82, 85, 87, 121, 122
Nesting depth
● per priority class
8
Counters, timers and their retentivity
S7 counter
● Number
64
of which retentive with battery
— adjustable
Yes
— lower limit
0
— upper limit
63
of which retentive without battery
— adjustable
Yes
— lower limit
0
— upper limit
63
Counting range
— lower limit
0
— upper limit
999
S7 times
● Number
128
of which retentive with battery
— adjustable
Yes
— lower limit
0
— upper limit
127
of which retentive without battery
— adjustable
Yes
— lower limit
0
— upper limit
127
Time range
— lower limit
10 ms
— upper limit
9 990 s
Data areas and their retentivity
Flag
● Number, max.
256 byte
● Retentivity available
Yes
● of which retentive with battery
0 to 2047
● of which retentive without battery
0 to 2047
Address area
I/O address area
● Inputs
1 kbyte
● Outputs
1 kbyte
Process image
● Inputs
128 byte
● Outputs
128 byte
Hardware configuration
Number of modules per system, max.
8
Number of modules per DP slave interface, max.
32; 122 byte address space per DP station
connectable programming devices/PCs
SIMATIC PG/PC, standard PC
Interface modules
● Interface module IM 360 integrated
Yes
Number of DP masters
● integrated
0
● via CP
1; CP 342-5
Number of operable FMs and CPs (recommended)
● FM
8
● CP, point-to-point
4
● CP, LAN
2
Expansion modules
● Number of expansion modules, max.
24
● Analog inputs/outputs, max.
192
● Digital inputs/outputs, max.
768
Rack
● Modules per rack, max.
8
● Rack, number of rows, max.
3
Time of day
Clock
● Hardware clock (real-time clock)
Yes; CPU
● Software clock
Yes; OP
Digital inputs
Number of digital inputs
16
Input voltage
● Rated value, DC
24 V
● for signal "0"
-3 to +5V
● for signal "1"
+11 to +30 V
Input current
● for signal "1", typ.
11.5 mA
Input delay (for rated value of input voltage)
for standard inputs
— at "0" to "1", max.
4.8 ms; typically 3 ms
Cable length
● Cable length, shielded, max.
1 000 m
● Cable length unshielded, max.
600 m
Digital outputs
Number of digital outputs
16
Short-circuit protection
Yes; Clocked electronically
Limitation of inductive shutdown voltage to
48 V
Switching capacity of the outputs
● Lamp load, max.
5 W
Output voltage
● for signal "1", min.
L+ (-0.8 V)
Output current
● for signal "1" rated value
0.5 A
● for signal "1" minimum load current
5 mA
● for signal "0" residual current, max.
0.5 mA
Switching frequency
● with resistive load, max.
100 Hz
● with inductive load, max.
0.5 Hz
Total current of the outputs (per group)
all mounting positions
— up to 20 °C, max.
4 A
— up to 40 °C, max.
2 A
Cable length
● Cable length, shielded, max.
1 000 m
● Cable length unshielded, max.
600 m
Universal inputs
Number of universal inputs
4
usable as
UI1, UI2: Digital/alarm input 24 V DC or up/down counter; UI3: Digital/alarm input 24 V DC or up/down counter or frequency/period duration counter; UI4: Digital/alarm input 24 V DC
Counter frequency, max.
10 kHz
Input voltage
● Rated value (DC)
24 V
● for signal "0"
-3 to +5V
● for signal "1"
+11 to +30 V
Input current
● for signal "1"
typ. 11.5 mA
Cable length, shielded, max.
1 000 m
Analog inputs
Number of analog inputs
4
permissible input voltage for voltage input (destruction limit), max.
30 V
permissible input current for current input (destruction limit), max.
30 mA
Cycle time (all channels), typ.
2 ms
Input ranges
● Voltage
Yes
● Current
Yes
Input ranges (rated values), voltages
● -10 V to +10 V
Yes
● Input resistance (-10 V to +10 V)
50 kΩ
Input ranges (rated values), currents
● -20 to +20 mA
Yes
● 4 to 20 mA
Yes
● Input resistance (4 to 20 mA)
105.5 kΩ
Analog outputs
Number of analog outputs
4
Voltage output, short-circuit protection
Yes
Voltage output, short-circuit current, max.
25 mA
Current output, no-load voltage, max.
16 V; +/-
Cycle time (all channels) max.
4 ms; typ. 2 ms
Output ranges, voltage
● -10 to +10 V
Yes
Output ranges, current
● -20 to +20 mA
Yes
● 4 to 20 mA
Yes
Load impedance (in rated range of output)
● with voltage outputs, min.
2 kΩ
● with voltage outputs, capacitive load, max.
1 µF
● with current outputs, max.
0.5 kΩ
● with current outputs, inductive load, max.
1 mH
Cable length
● Cable length, shielded, max.
200 m
Analog value generation
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max.
12 bit
● Conversion time (per channel)
0.5 ms
Settling time
● for resistive load
0.1 ms
● for capacitive load
3.3 ms
● for inductive load
0.5 ms
Encoder
Connectable encoders
● 2-wire sensor
Yes
— permissible quiescent current (2-wire sensor), max.
2 mA
Errors/accuracies
Operational error limit in overall temperature range
● Voltage, relative to input area, (+/-)
0.8 %
● Current, relative to input area, (+/-)
0.8 %
● Voltage, relative to output area, (+/-)
0.8 %
● Current, relative to output area, (+/-)
1 %
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input area, (+/-)
0.6 %
● Current, relative to input area, (+/-)
0.6 %
● Voltage, relative to output area, (+/-)
0.5 %
● Current, relative to output area, (+/-)
0.6 %
Interfaces
Number of printer interfaces
1; RS 232
PROFIBUS DP
● Transmission rate, max.
12 Mbit/s
MPI
● Cable length, max.
9 100 m; without repeaters 50 m; with 2 repeaters: 1100 m; with 10 repeaters in series: 9100 m; via fiber optic cable: 23.8 km (with star hubs or OLMs)
1. Interface
Functionality
● MPI
Yes; occupies 2 nodes per device (1 x CPU, 1 x OP)
● DP master
No
● DP slave
No
MPI
● Number of nodes, max.
32; PG/PC, OP, C7, S7-300/400, M7
● Transmission rate, max.
187.5 kbit/s
Communication functions
PG/OP communication
Yes
Global data communication
● supported
Yes
S7 basic communication
● supported
Yes
S7 communication
● S7 extended communication
Yes; Server
S5 compatible communication
● supported
Yes
Standard communication (FMS)
● supported
Yes
Number of connections
● overall
— of which dynamic
8
— of which static
4
Interrupts/diagnostics/status information
Substitute values connectable
Yes; Parameterizable
Alarms
● Alarm cycle
Yes; Parameterizable
● Diagnostic alarm
Yes; Measurement overrange, wire break detection at 4 to 20 mA by means of software; parameterizable for parameter errors
Diagnostic messages
● Diagnostic functions
Yes; C7-CPU
Counter
Number of counter inputs
3; UE1, UE2, UE3
Principle
Counting of edges
Counting range, description
UI1, UI2: up: 0 to 65535, down: 65535 to 0; UI3: up: 0 to 16777215, down: 16777215 to 0
Counting alarm backward counter
on reaching "0"
Counting alarm forward counter
on reaching limit value
Enable
In the program
Limit value (setpoint) default
one counter per value
External gate counters
● Number of external gate counters
3
● Principle
Counting of edges within a gate time via external pin
● Counting range
UE1, UE2: 0 to 65535; UE3: 0 to 16777215
Frequency counter
Number of frequency counters
1; UI3
Principle
Counting of pulses within a time period
Gate width, adjustable
Yes
Gate width
0.1 / 1 / 10 s (adjustable)
Counting range
0 to 16777215
Cycle duration counter
Number
1; UI3
Cycle duration, max.
8.38 s; or 0.12 Hz
Principle
Counting of fixed time units between two positive edges
Fatal Error: Can't alloc dataspace in /www/wwwroot/www.kollewin.com/system/secache/secache.php on line 617
Warning: fopen(/www/wwwroot/www.kollewin.com/system/logs/error.txt): failed to open stream: Permission denied in /www/wwwroot/www.kollewin.com/system/library/log.php on line 12
Warning: fwrite() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 14
Warning: fclose() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 16
Warning: alloc datasize:976632435 in /www/wwwroot/www.kollewin.com/system/secache/secache.php on line 617
Warning: fopen(/www/wwwroot/www.kollewin.com/system/logs/error.txt): failed to open stream: Permission denied in /www/wwwroot/www.kollewin.com/system/library/log.php on line 12
Warning: fwrite() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 14
Warning: fclose() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 16