6ES7626-2DG04-0AE3 SIMATIC C7-626/P DP, COMP. UNIT

Product Code: 6ES7626-2DG04-0AE3

Availability: In Stock

Price: $3,075.65
  
 
Artikelnummer 6ES7626-2DG04-0AE3
SIMATIC C7-626/P DP, COMP. UNIT WITH INTEGRATED COMPONENTS: S7-300 CPU 315 2DP (128 KB), SIMATIC OP25 AND IM 360, 16 DI, 16 DO, 4 AI, 4AO, 4 UI
Operator control and monitoring
Password protection Yes
Password levels 9
Graphics object
● Semigraphic Yes
● Pixel graphics Yes; Access to external editors
Process images
● Number of process images depending on user memory
● Number of variables in message text, max. 8
Operating / fault messages
● Operating messages
— Operating messages, max. 2 000; depending on user memory
— Scroll operating messages, max. 512
— Number of entries in operational log, max. 512; Entries in ring buffer
● Fault messages Yes
— Number of fault message, max. 2 000; depending on user memory
— Number of entries in fault message buffer, max. 512; Entries in ring buffer
● Number of symbol/character sets 4
Recipes
● Number of recipes, max. 255
● Data records per recipe, max. 500
● Entries per data record, max. 500
● Recipe data memory, max. 64 kbyte
Display
Design of display LC-Display, CCFL-backlit, passive mono; active display area 105 x 79 mm
dynamic objects Input, output, input/output fields, date/time fields, symbolic input/output fields, bar graphs, characteristics, pictorial presentation etc.
Resolution (pixels)
● Horizontal image resolution 320
● Vertical image resolution 240
Backlighting
● MTBF backlighting (at 20 °C) 20 000 h; about 2.2 years
Control elements
Keyboard
● Number of function keys 10
● Number of softkeys 14
Supply voltage
24 V DC Yes
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 30.2 V
Load voltage L+
● Rated value (DC) 24 V
● permissible range, lower limit (DC) 20.4 V
● permissible range, upper limit (DC) 28.8 V
Input current
Current consumption, typ. 700 mA
Current consumption, max. 2 A
Power losses
Power loss, typ. 17 W
Memory
Work memory
● Integrated 96 kbyte; RAM 96 KB/32 K instructions (integrated); 2 MB dyn. RAM
Load memory
● integrated FEPROM, max. 512 kbyte
● integrated RAM, max. 260 kbyte
Backup
● present Yes
● with battery Yes; all data
● without battery Yes; 4736 Byte: parameterizable for memory bits, times, counters, data
CPU processing times
for bit operations, typ. 0.3 µs
for bit operations, max. 0.6 µs
for word operations, typ. 1 µs
for fixed point arithmetic, typ. 2 µs
for floating point arithmetic, typ. 50 µs
for timer/counter operations, typ. 12 µs
CPU-blocks
DB
● Number, max. 255; DB 0 reserved
FB
● Number, max. 192; see instruction list
FC
● Number, max. 192; see instruction list
OB
● Number, max. see instruction list
● Number of free cycle OBs 1; OB 1
● Number of time alarm OBs 1; OB 10
● Number of time interrupt OBs 1; OB 35
● Number of process alarm OBs 1; OB 40
● Number of startup OBs 1; OB 100
● Number of asynchronous error OBs 8; OB 80, 81, 82, 85, 86, 87, 121, 122
Nesting depth
● per priority class 8
Counters, timers and their retentivity
S7 counter
● Number 64
of which retentive with battery
— can be set Yes
— lower limit 0
— upper limit 63
of which retentive without battery
— can be set Yes
— lower limit 0
— upper limit 63
Counting range
— lower limit 0
— upper limit 999
S7 times
● Number 128
of which retentive with battery
— can be set Yes
— lower limit 0
— upper limit 127
of which retentive without battery
— can be set Yes
— lower limit 0
— upper limit 127
Time range
— lower limit 10 ms
— upper limit 9 990 s
Data areas and their retentivity
Flag
● Number, max. 256 byte
● Retentivity available Yes
● of which retentive with battery 0 to 2047
● of which retentive without battery 0 to 2047
Address area
I/O address area
● Inputs 1 kbyte
● Outputs 1 kbyte
Process image
● Inputs 128 byte
● Outputs 128 byte
Hardware configuration
Number of modules per system, max. 8
Number of modules per DP slave interface, max. 32; 122 byte address space per DP station
Connectable programming devices/PCs SIMATIC PG/PC, standard PC
Interface modules
● Interface module IM 360 integrated Yes
Number of DP masters
● Integrated 1
● Via CP 1; CP 342-5
Number of operable FMs and CPs (recommended)
● FM 8
● CP, point-to-point 4
● CP, LAN 2
Expansion modules
● Number of expansion modules, max. 24
● Analog inputs/outputs, max. 192
● Digital inputs/outputs, max. 768
Rack
● Modules per rack, max. 8
● Rack, number of rows, max. 3
Time of day
Clock
● Hardware clock (real-time clock) Yes
Digital inputs
Number of digital inputs 16
Input voltage
● Rated value, DC 24 V
● for signal "0" -3 to +5V
● for signal "1" +11 to +30 V
Input current
● for signal "1", typ. 11.5 mA
Input delay (for rated value of input voltage)
for standard inputs
— at "0" to "1", max. 4.8 ms; typically 3 ms
Cable length
● Cable length, shielded, max. 1 000 m
● Cable length unshielded, max. 600 m
Digital outputs
Number of digital outputs 16
short-circuit protection Yes; Clocked electronically
Limitation of inductive shutdown voltage to 48 V
Switching capacity of the outputs
● Lamp load, max. 5 W
Output voltage
● for signal "1", min. L+ (-0.8 V)
Output current
● for signal "1" rated value 0.5 A
● for signal "1" minimum load current 5 mA
● for signal "0" residual current, max. 0.5 mA
Switching frequency
● with resistive load, max. 100 Hz
● with inductive load, max. 0.5 Hz
Aggregate current of outputs (per group)
all mounting positions
— up to 20 °C, max. 4 A
— up to 40 °C, max. 2 A
Cable length
● Cable length, shielded, max. 1 000 m
● Cable length unshielded, max. 600 m
Universal inputs
Number of universal inputs 4
usable as UI1, UI2: Digital/alarm input 24 V DC or up/down counter; UI3: Digital/alarm input 24 V DC or up/down counter or frequency/period duration counter; UI4: Digital/alarm input 24 V DC
Counter frequency, max. 10 kHz
Input voltage
● Rated value (DC) 24 V
● for signal "0" -3 to +5V
● for signal "1" +11 to +30 V
Input current
● for signal "1" typ. 11.5 mA
Cable length, shielded, max. 1 000 m
Analog inputs
Number of analog inputs 4
permissible input voltage for voltage input (destruction limit), max. 30 V
permissible input current for current input (destruction limit), max. 30 mA
Cycle time (all channels), typ. 2 ms
Input ranges
● Voltage Yes
● Current Yes
Input ranges (rated values), voltages
● -10 V to +10 V Yes
● Input resistance (-10 V to +10 V) 50 kΩ
Input ranges (rated values), currents
● -20 to +20 mA Yes
● Input resistance (-20 to +20 mA) 105.5 Ω
● 4 to 20 mA Yes
● Input resistance (4 to 20 mA) 105.5 Ω
Analog outputs
Number of analog outputs 4
Voltage output, short-circuit protection Yes
Voltage output, short-circuit current, max. 25 mA
Current output, no-load voltage, max. 16 V; +/-
Cycle time (all channels) max. 4 ms; typ. 2 ms
Output ranges, voltage
● -10 to +10 V Yes
Output ranges, current
● -20 to +20 mA Yes
● 4 to 20 mA Yes
Load impedance (in rated range of output)
● with voltage outputs, min. 2 kΩ
● with voltage outputs, capacitive load, max. 1 µF
● with current outputs, max. 0.5 kΩ
● with current outputs, inductive load, max. 1 mH
Cable length
● Cable length, shielded, max. 200 m
Analog value creation
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 12 bit
● Conversion time (per channel) 0.5 ms
Settling time
● for resistive load 0.1 ms
● for capacitive load 3.3 ms
● for inductive load 0.5 ms
Encoder
Connectable encoders
● 2-wire sensor Yes
— Permissible quiescent current (2-wire sensor), max. 2 mA
Errors/accuracies
Operational limit in overall temperature range
● Voltage, relative to input area, (+/-) 0.8 %
● Current, relative to input area, (+/-) 0.8 %
● Voltage, relative to output area, (+/-) 0.8 %
● Current, relative to output area, (+/-) 1 %
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input area, (+/-) 0.6 %
● Current, relative to input area, (+/-) 0.6 %
● Voltage, relative to output area, (+/-) 0.5 %
● Current, relative to output area, (+/-) 0.6 %
Interfaces
Number of printer interfaces 1; RS 232
MPI
● Cable length, max. 9 100 m; without repeaters 50 m; with 2 repeaters: 1100 m; with 10 repeaters in series: 9100 m; via fiber optic cable: 23.8 km (with star hubs or OLMs)
1st interface
Functionality
● MPI Yes
● DP master Yes
● DP slave Yes
MPI
● Number of nodes, max. 32; PG/PC, OP, C7, S7-300/400, M7
● Transmission rate, max. 187.5 kbit/s
DP master
● Transmission rate, max. 12 Mbit/s
2nd interface
Functionality
● DP master Yes
● DP slave Yes
DP master
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 64
User data per DP slave
— User data per DP slave, max. 122 byte
Communication functions
PG/OP communication Yes
Global data communication
● supported Yes
S7 basic communication
● supported Yes
S7 communication
● S7 extended communication Yes; Server
S5-compatible communication
● supported Yes
Standard communication (FMS)
● supported Yes; occupies 2 nodes per device (1 x CPU, 1 x OP)
Number of connections
● overall
— of which dynamic 8
— of which static 4
Interrupts/diagnostics/status information
Substitute values connectable Yes; Parameterizable
Alarms
● Alarm cycle Yes; Parameterizable
● Diagnostic alarm Yes; parameterizable for parameter errors, measuring range exceeded, wire break detection at 4 to 20 mA via software
Diagnostic messages
● Diagnostic functions Yes
Counter
Number of counter inputs 3; UE1, UE2, UE3
Principle Counting of edges
Counting range, description UI1, UI2: up: 0 to 65535, down: 65535 to 0; UI3: up: 0 to 16777215, down: 16777215 to 0
Counting alarm backward counter on reaching "0"
Counting alarm forward counter on reaching limit value
Release In the program
Limit value (setpoint) default one counter per value
Frequency counter
Number of frequency counters 1; UI3
Principle Counting of pulses within a time period
Gate width, adjustable Yes
Gate width 0.1 / 1 / 10 s
Counting range 0 to 16777215
Cycle duration counter
Number 1; UI3
Cycle duration, max. 8.38 s; or 0.12 Hz
Principle Counting of fixed time units between two positive edges
Gate width 0.1 / 1 / 10 s (adjustable)
Counting range, lower limit 0
Counting range, upper limit 16 777 214
Galvanic isolation
Galvanic isolation digital inputs
● Galvanic isolation digital inputs Yes
● between the channels, in groups of 16
Galvanic isolation digital outputs
● Galvanic isolation digital outputs Yes; Optocoupler
● between the channels, in groups of 8
Galvanic isolation analog inputs
● Galvanic isolation analog inputs Yes; shared with AO
Galvanic isolation analog outputs
● Galvanic isolation analog outputs Yes; shared with AI
Electrical isolation channels
● Galvanic isolation universal inputs No
Isolation
Isolation checked with 500 V DC
EMC
Emission of radio interference acc. to EN 55 022
● Interference emission acc. to EN 55022, class A Yes; Noise emission: Class A / EN 55022; conducted interference: IEC 1000-4-4, IEC 1000-4-5; noise immunity: IEC 1000-4-2, IEC 1000-4-3, IEC 1000-4-4, IEC 1000-4-6, EN 50140
Degree and class of protection
Degree of protection to EN 60529
● IP20 Yes; Housing
● IP65 Yes; Front
Standards, approvals, certificates
DIN/ISO 9001 Yes; Certification of production and development
CSA approval Yes; C22.2 Number 142
UL approval Yes; UL 508
FM approval Yes; FM-Standards No. 3611, 3600, 3810 Class I, Division 2, Group A, B, C, D
Developed in accordance with IEC 61131 Yes; EN 61131-2 (IEC 1131-2)
Ambient conditions
Operating temperature
● 45 degree installation, min. 0 °C
● 45 degree installation, max. 30 °C
● horizontal installation, min. 0 °C
● horizontal installation, max. 45 °C; possible with forced ventilation
● vertical installation, min. 0 °C
● vertical installation, max. 45 °C
Air pressure
● permissible range, min. 795 hPa
● permissible range, max. 1 080 hPa
Relative humidity
● Operation, min. 5 %
● Operation, max. 95 %; RH class 2 in accordance with IEC 1131-2
Vibrations
● Operation, checked according to IEC 60068-2-6 Yes; IEC 68, Part 2-6; 10 to 58 Hz; (constant amplitude 0.075 mm); 58 to 500 Hz; (constant acceleration 9.8 m/s2)
Shock test
● checked according to IEC 60068-2-29 Yes; IEC 68, Part 2-29 half-sine: 100 m/s2 (10 g), 16 ms, 100 shocks
Configuration
Configuration software
● STEP 7 Yes
● STEP 7 Mini Yes
● ProTool Yes
● ProTool/Pro Yes
programming
● Command set see instruction list
● Nesting levels 8
● Program organization Linear, structured
● System functions (SFC) see instruction list
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Software libraries
— Process diagnostics Yes; S7-CPU and C7-OP
— Software controller Yes; 16 circles
Know-how protection
● User program protection/password protection Yes
Cycle time monitoring
● lower limit 1 ms
● upper limit 6 000 ms
● can be set Yes
● preset 150 ms
Languages
Online languages
● Number of online/runtime languages 3
Dimensions
Width 240 mm
Height 168 mm
Depth 69 mm
Mounting cutout/device depth (W x H x T)
● Mounting cutout, width 231 mm
● Mounting cutout, height 159 mm
Weights
Weight, approx. 1 780 g
last modified: 25.09.2014