6ES7613-1CA01-0AE3 C7-613, COMPACT UNIT, 24DI/16DO/5AI/2AO

Product Code: 6ES7613-1CA01-0AE3

Availability: In Stock

Price: $664.45
  
 
Artikelnummer 6ES7613-1CA01-0AE3
SIMATIC C7-613, COMPACT UNIT WITH 4 LINE DISPLAY, KEYS AND S7-300 CPU313C WITH 24 DI, 16 DO, 5 AI, 2 AO; MICRO MEMORY CARD AND CONNECTOR SET REQUIRED
Operator control and monitoring
Password protection Yes
Info texts Yes; 128
Alarms Yes; with buffer
Graphics object
● Graphics object Yes
Process images
● Number of process images 128
● Number of variables per image, max. 8
Display
Design of display LCD backlit
Line display
● Number of lines 4
● Number of characters per line 20
Backlighting
● MTBF backlighting (at 20 °C) 100 000 h
Control elements
Keyboard
● Number of function keys 10; Can be used simultaneously as numeric input
● Number of softkeys 4
Supply voltage
24 V DC Yes
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Load voltage L+
● Rated value (DC) 24 V
● permissible range, lower limit (DC) 20.4 V
● permissible range, upper limit (DC) 28.8 V
Input current
Current consumption, typ. 350 mA; idling
Inrush current, max. 2 A; for 70 ms
Power losses
Power loss, typ. 11 W
Memory
Micro Memory Card Yes; All data located on MMC of the CPU
Work memory
● Integrated 32 kbyte; For program and data
● expandable No
Load memory
● pluggable (MMC) Yes
● pluggable (MMC), max. 8 Mbyte
Backup
● present Yes; Guaranteed by MMC (maintenance-free)
● without battery Yes; Program and data
CPU processing times
for bit operations, typ. 0.1 µs
for bit operations, max. 0.2 µs
for word operations, typ. 0.2 µs
for fixed point arithmetic, typ. 2 µs
for floating point arithmetic, typ. 3 µs
CPU-blocks
DB
● Number, max. 127; DB 0 reserved
● Size, max. 16 kbyte
FB
● Number, max. 128
● Size, max. 16 kbyte
FC
● Number, max. 128
● Size, max. 16 kbyte
OB
● Size, max. 16 kbyte
● Number of time alarm OBs 1
● Number of delay alarm OBs 1
● Number of time interrupt OBs 1
● Number of process alarm OBs 1
Nesting depth
● per priority class 6
● additional within an error OB 4
Counters, timers and their retentivity
S7 counter
● Number 256
of which retentive without battery
— can be set Yes
— lower limit 0
— upper limit 256
Counting range
— lower limit 0
— upper limit 999
IEC counter
● present Yes
● Type SFB
S7 times
● Number 256
of which retentive without battery
— can be set Yes
— lower limit 0
— upper limit 256
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
● Type SFB
Data areas and their retentivity
Flag
● Number, max. 256 byte
● Retentivity available Yes; MB 0 to MB 255
Address area
I/O address area
● Inputs 1 kbyte
● Outputs 1 kbyte
Process image
● Inputs 128 byte
● Outputs 128 byte
Digital channels
● Inputs 992
● Outputs 992
Analog channels
● Inputs 248
● Outputs 124
Hardware configuration
Number of DP masters
● Via CP 1
Number of operable FMs and CPs (recommended)
● FM 4
● CP, point-to-point 4
● CP, LAN 4
Expansion modules
● Number of expansion modules, max. 4; max. 2 flat structure, max. 4 deep structure
Rack
● Racks, max. 1
● Modules per rack, max. 4
Time of day
Clock
● Hardware clock (real-time clock) Yes
● battery-backed and synchronizable Yes
Operating hours counter
● Number 1
Clock synchronization
● supported Yes
Digital inputs
Number of digital inputs 24
Input voltage
● Rated value, DC 24 V
● for signal "0" -3 to +5V
● for signal "1" 15 to 30 V
Input current
● for signal "1", typ. 8 mA
Input delay (for rated value of input voltage)
for standard inputs
— Parameterizable Yes; 0.1 / 0.3 / 3 / 15 ms
for counter/technological functions
— at "0" to "1", max. 16 µs
Cable length
● Cable length, shielded, max. 1 000 m; 100 m for technological functions
● Cable length unshielded, max. 600 m
Digital outputs
Number of digital outputs 16
short-circuit protection Yes; Clocked electronically
Limitation of inductive shutdown voltage to L+ (-48 V)
Output voltage
● for signal "1", min. L+ (-0.8 V)
Output current
● for signal "1" permissible range for 0 to 40 °C, max. 0.5 A
● for signal "1" permissible range for 40 to 60 °C, max. 0.5 A
● for signal "1" minimum load current 5 mA
● for signal "0" residual current, max. 0.5 mA
Switching frequency
● with resistive load, max. 100 Hz
● with inductive load, max. 0.5 Hz
Aggregate current of outputs (per group)
all mounting positions
— up to 40 °C, max. 4 000 mA
— up to 60 °C, max. 2 000 mA
Cable length
● Cable length, shielded, max. 1 000 m
● Cable length unshielded, max. 600 m
Analog inputs
Number of analog inputs 4
Number of analog inputs for voltage/current measurement 4
Number of analog inputs for resistance/resistance thermometer measurement 1
Input ranges
● Voltage Yes
● Current Yes
● Resistance thermometer Yes
● Resistance Yes
Input ranges (rated values), voltages
● 0 to +10 V Yes
● -10 V to +10 V Yes
Input ranges (rated values), currents
● 0 to 20 mA Yes
● -20 to +20 mA Yes
● 4 to 20 mA Yes
Input ranges (rated values), resistance thermometer
● Pt 100 Yes
Input ranges (rated values), resistors
● 0 to 600 ohms Yes
Analog outputs
Number of analog outputs 2
Output ranges, voltage
● 0 to 10 V Yes
● -10 to +10 V Yes
Output ranges, current
● 0 to 20 mA Yes
● -20 to +20 mA Yes
● 4 to 20 mA Yes
Analog value creation
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 12 bit
● Integration time, parameterizable Yes; 2,5 / 16,6 / 20 ms
● Conversion time (per channel) 1 ms
Encoder
Connectable encoders
● 2-wire sensor Yes
— Permissible quiescent current (2-wire sensor), max. 1.5 mA
Errors/accuracies
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input area, (+/-) 0.7 %
● Current, relative to input area, (+/-) 0.7 %
● Resistance, relative to input area, (+/-) 3 %
● Resistance thermometer, relative to input area, (+/-) 3 %
● Voltage, relative to output area, (+/-) 0.7 %
● Current, relative to output area, (+/-) 0.7 %
Interfaces
MPI
● Cable length, max. 50 m; without repeater
1st interface
Isolated No
Functionality
● MPI Yes
● DP master No
● DP slave No
MPI
● Number of connections 8
● Transmission rate, max. 187.5 kbit/s
Services
— PG/OP communication Yes
— Global data communication Yes
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
Communication functions
PG/OP communication Yes
Global data communication
● Number of GD packets, transmitter, max. 4
● Number of GD packets, receiver, max. 4
● Size of GD packets, max. 22 byte
S7 basic communication
● supported Yes
● User data per job, max. 76 byte
S7 communication
● supported Yes
● User data per job, max. 64 kbyte
Number of connections
● overall 8
● usable for PG communication
— reserved for PG communication 1
— Adjustable for PG communication, max. 7
● usable for OP communication
— reserved for OP communication 1
— adjustable for OP communication, max. 7
● usable for S7 basic communication
— Reserved for S7 basic communication 4
— adjustable for S7 basic communication, max. 4
● Number of logical connections (also in network), max. 1; fixed with integrated CPU
S7 message functions
Number of login stations for message functions, max. 5
Integrated Functions
Number of counters 3
Counter frequency (counter) max. 30 kHz
Frequency measurement Yes
PID controller Yes
Number of pulse outputs 3
Limit frequency (pulse) 2.5 kHz
Galvanic isolation
Galvanic isolation digital inputs
● between the channels Yes
● between the channels, in groups of 8; 16 and 8
Galvanic isolation digital outputs
● between the channels Yes
● between the channels, in groups of 8
Galvanic isolation analog inputs
● Galvanic isolation analog inputs Yes; common for analog I/O
Galvanic isolation analog outputs
● Galvanic isolation analog outputs Yes; common for analog I/O
Isolation
tested with
● 24 V DC circuits 500 V; DC
EMC
Emission of radio interference acc. to EN 55 011
● Emission of radio interference Interference emission to EN 50081-2, testing to EN 55011, Class A, Group 1
● Limit class A, for use in industrial areas Yes; Group 1
Degree and class of protection
Degree of protection to EN 60529
● IP20 Yes; Housing
● IP65 Yes; Front
Ambient conditions
Environmental conditions Not suitable for open-air use
Operating temperature
● 45 degree installation, min. 0 °C
● 45 degree installation, max. 45 °C
● horizontal installation, min. 0 °C
● horizontal installation, max. 40 °C
● vertical installation, min. 0 °C
● vertical installation, max. 50 °C
Air pressure
● permissible range, min. 795 hPa
● permissible range, max. 1 080 hPa
Relative humidity
● Operation, min. 5 %
● Operation, max. 95 %; RH class 2 in accordance with IEC 1131-2
Vibrations
● Operation, checked according to IEC 60068-2-6 Yes; 10 to 58 Hz: Constant amplitude 0.075 mm; 58 to 500 Hz: Constant acceleration 1 g
● Transport tested checked to IEC 60068-2-6 Yes; 5 to 9 Hz: amplitude 3.5 mm; 9 to 500 Hz: acceleration 1 g
Shock test
● checked according to IEC 60068-2-29 Yes; in operation: Half-sine: Strength of the shock 15 g (peak value), duration 11 ms, 18 shocks; in storage: 25 g, 6 ms, 1000 shocks
Configuration
Configuration software
● STEP 7 Yes; V5.1 SP3, STEP 7 Lite
programming
● Nesting levels 8
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Know-how protection
● User program protection/password protection Yes
Languages
Online languages
● Number of online/runtime languages 3
Mechanics/material
Lifetime, typ.
● Number of operating cycles, keys 1 000 000
Dimensions
Width 215 mm
Height 165 mm
Depth 79 mm
Mounting cutout/device depth (W x H x T)
● Mounting cutout, width 202 mm
● Mounting cutout, height 152 mm
Weights
Weight, approx. 1 350 g
last modified: 25.09.2014

Write a review

Note: HTML is not translated!

Rating: Bad Good

Enter the code in the box below: