6ES7151-7AA13-0AB0 ET200S, INTERFACE MOD. IM151-7 CPU, 64KB

Product Code: 6ES7151-7AA13-0AB0

Availability: In Stock

Price: $384.29
  
 
Artikelnummer 6ES7151-7AA13-0AB0
SIMATIC DP, IM151-7 CPU FOR ET200S, 96 KB WORKING MEMORY INTEGR. PROFIBUS DP INTERFACE (9 PIN SUB-D, FEMALE) AS DP SLAVE, W/O BATTERY
General information
Hardware product version 01
Firmware version V2.1.10
Engineering with
● Programming package STEP 7 V5.3 or higher with HW update
Supply voltage
Load voltage L+
● Rated value (DC) 24 V
● permissible range, lower limit (DC) 20.4 V
● permissible range, upper limit (DC) 28.8 V
● short-circuit protection Yes
● Reverse polarity protection Yes
Input current
from supply voltage 1L+, max. 250 mA; 280 mA with DP master module
Output current
Current output to backplane bus (DC 5 V), max. 700 mA
Power losses
Power loss, typ. 3.3 W
Memory
Work memory
● Integrated 96 kbyte; For program and data
● expandable No
Load memory
● pluggable (MMC) Yes
● pluggable (MMC), max. 8 Mbyte
● Data management on MMC (after last programming), min. 10 y
Backup
● present Yes; Guaranteed by MMC (maintenance-free)
CPU processing times
for bit operations, typ. 0.1 µs
for word operations, typ. 0.2 µs
for fixed point arithmetic, typ. 2 µs
for floating point arithmetic, typ. 3 µs
CPU-blocks
Number of blocks (total) 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
● Number, max. 511; from DB1 to DB511
● Size, max. 16 kbyte
FB
● Number, max. 1 024; In number range from FB 0 to FB 2047
● Size, max. 16 kbyte
FC
● Number, max. 1 024; In number band of FC0 to FC2047
● Size, max. 16 kbyte
OB
● Number, max. see instruction list
● Size, max. 16 kbyte
● Number of free cycle OBs 1; OB 1
● Number of time alarm OBs 1; OB 10
● Number of delay alarm OBs 1; OB 20
● Number of time interrupt OBs 1; OB 35
● Number of process alarm OBs 1; OB 40
● Number of startup OBs 1; OB 100
● Number of asynchronous error OBs 6; OB 80, 82, 83, 85, 86, 87
Nesting depth
● per priority class 8
● additional within an error OB 4
Counters, timers and their retentivity
S7 counter
● Number 256
Retentivity
— can be set Yes
— lower limit 0
— upper limit 255
— preset Z 0 to Z 7
Counting range
— can be set Yes
— lower limit 0
— upper limit 999
IEC counter
● present Yes
● Type SFB
● Number Unlimited (limited only by RAM capacity)
S7 times
● Number 256
Retentivity
— can be set Yes
— lower limit 0
— upper limit 255
— preset No times retentive
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
● Type SFB
● Number Unlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area in total (incl. times, counters, flags), max. 64 kbyte
Flag
● Number, max. 256 byte
● Retentivity available Yes
● Retentivity preset MB 0 to MB 15
● Number of clock memories 8; 1 memory byte
Data blocks
● Number, max. 511; DB 0 reserved
● Size, max. 16 kbyte
Local data
● per priority class, max. 510 byte
Address area
I/O address area
● Inputs 2 048 kbyte
● Outputs 2 048 kbyte
Process image
● Inputs 128 byte; Not adjustable
● Outputs 128 byte; Not adjustable
Digital channels
● Inputs 16 336
● Outputs 16 336
● Inputs, of which central 248
● Outputs, of which central 248
Analog channels
● Inputs 1 021
● Outputs 1 021
● Inputs, of which central 124
● Outputs, of which central 124
Time of day
Clock
● Hardware clock (real-time clock) Yes
● battery-backed and synchronizable Yes
● Deviation per day, max. 10 s
● Backup time 6 wk; At 40 °C ambient temperature, typically
Operating hours counter
● Number 1
● Number/Number range 0
● Range of values 0 to 2^31 hours (when using SFC 101)
● Granularity 1 hour
● retentive Yes; Must be restarted at each restart
Clock synchronization
● supported Yes
● to MPI, master Yes
● to MPI, slave Yes
● in AS, master No
● in AS, slave No
1st interface
Interface type Integrated RS 485 interface
Physics RS 485
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 80 mA
Functionality
● MPI Yes
● DP master No
● DP slave Yes; active / passive
● Point-to-point connection No
MPI
● Number of connections 12; Notice: 12 connections per CPU, not per interface
● Transmission rate, max. 12 Mbit/s
Services
— PG/OP communication Yes
— Routing Yes; With master module
— Global data communication Yes
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
DP slave
● Number of connections 12; Notice: 12 connections per CPU, not per interface
● GSD file http://www.siemens.com/profibus-gsd
● Transmission rate, max. 12 Mbit/s
● Automatic baud rate search Yes; only with passive interface
● Address area, max. 32
● User data per address area, max. 32 byte; Up to max. size of the transfer memory
Services
— Routing Yes; Only when interface active and in master mode
— S7 communication, as client No
— S7 communication, as server Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV1 No
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
2nd interface
Interface type External interface via master module 6ES7138-4HA00-0AB0
Physics RS 485
Isolated Yes
Power supply to interface (15 to 30 V DC), max. No
Functionality
● MPI No
● DP master Yes
● Point-to-point connection No
DP master
● Number of connections, max. 12; Notice: 12 connections per CPU, not per interface
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 32; Per station
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
— Equidistance mode support Yes
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV1 Yes
Address area
— Inputs, max. 2 kbyte
— Outputs, max. 2 kbyte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
Communication functions
PG/OP communication Yes
Global data communication
● supported Yes
● Number of GD packets, max. 4
● Number of GD packets, transmitter, max. 4
● Number of GD packets, receiver, max. 4
● Size of GD packets, max. 22 byte
● Size of GD packet (of which consistent), max. 22 byte
S7 basic communication
● supported Yes
● User data per job, max. 76 byte
● User data per job (of which consistent), max. 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
● supported Yes
● as server Yes
● As client No
● User data per job, max. 180 byte
● User data per job (of which consistent), max. 64 byte
S5-compatible communication
● supported No
Standard communication (FMS)
● supported No
Number of connections
● overall 12
● usable for PG communication 11
— reserved for PG communication 1
● usable for OP communication 11
— reserved for OP communication 1
● usable for S7 basic communication 10
— Reserved for S7 basic communication 0
● usable for routing 4; As slave only with active interface, with IM 151-7 CPU as DP master
S7 message functions
Number of login stations for message functions, max. 12; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messages Yes; ALARM_S, ALARM_SC, ALARM_SQ
simultaneously active Alarm-S blocks, max. 40
Test commissioning functions
Status block Yes
Single step Yes
Number of breakpoints 2
Status/control
● Status/control variable Yes
● Variables Inputs, outputs, memory bits, DB, times, counters
● Number of variables, max. 30
● of which status variables, max. 30
● of which control variables, max. 14
Forcing
● Forcing Yes
● Force, variables Inputs, outputs
● Number of variables, max. 10
Diagnostic buffer
● present Yes
● Number of entries, max. 100
— can be set No
Galvanic isolation
between load voltage and all other switching components Yes
between PROFIBUS DP and all other circuit components Yes
Permissible potential difference
between different circuits 75 VDC / 60 VAC
Isolation
Isolation checked with 500 V DC
Configuration
Configuration rules max. 63 peripheral modules per station; station width < 1 m or < 2 m; max. 10 A per load group (power module); master interface module on right next to IM 151-7 CPU (X2 interface)
Configuration software
● STEP 7 Yes
programming
● Command set see instruction list
● Nesting levels 8
● System functions (SFC) see instruction list
● System function blocks (SFB) see instruction list
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes; Optional
— GRAPH Yes; Optional
Know-how protection
● User program protection/password protection Yes
Cycle time monitoring
● lower limit 1 ms
● upper limit 6 000 ms
● can be set Yes
● preset 150 ms
Dimensions
Width 60 mm; DP master module: 35 mm
Height 119.5 mm
Depth 75 mm
Weights
Weight, approx. 200 g; DP master module: Approx. 100 g