SIMATIC DP, BASIC MODULE ET200X: BM147-2 CPU, FOR PREPROCESSING WITH INT. PLC FUNCTIONS, INT.PROFIBUS DP SLAVE IF WITH ADD. PROFIBUS DP MASTER IF, PROT. IP65/67 |
|
Supply voltage |
Load voltage 1L+ |
Rated value (DC) |
24 V; Permissible range: 20.4V to 28.8V |
Short-circuit protection |
Yes; internal (thermally reversible); no for looping through |
Reverse polarity protection |
No |
Load voltage 2L+ |
Rated value (DC) |
24 V; Permissible range: 20.4V to 28.8V |
Reverse polarity protection |
No |
Power loss |
Power loss, typ. |
3 W |
Memory |
Work memory |
integrated |
48 kbyte |
expandable |
No |
Load memory |
expandable FEPROM, max. |
8 Mbyte; can be plugged in as MMC |
Backup |
present |
Yes; Guaranteed by MMC (maintenance-free) |
CPU processing times |
for bit operations, typ. |
0.1 µs |
for word operations, typ. |
0.2 µs |
for fixed point arithmetic, typ. |
2 µs |
for floating point arithmetic, typ. |
3 µs |
CPU-blocks |
Number of blocks (total) |
1024; DBs, FCs, FBs |
DB |
Number, max. |
511 |
Size, max. |
16 kbyte |
FB |
Number, max. |
512; see instruction list |
Size, max. |
16 kbyte |
FC |
Number, max. |
512; see instruction list |
Size, max. |
16 kbyte |
OB |
Description |
see instruction list |
Size, max. |
16 kbyte |
Nesting depth |
per priority class |
8 |
additional within an error OB |
4 |
Counters, timers and their retentivity |
S7 counter |
Number |
256 |
Retentivity |
adjustable |
Yes |
preset |
Z 0 to Z 7 |
Counting range |
lower limit |
0 |
upper limit |
999 |
IEC counter |
present |
Yes; Number unlimited (limited only by work memory) |
Type |
SFB |
S7 times |
Number |
256 |
Retentivity |
adjustable |
Yes |
preset |
No retentivity |
Time range |
lower limit |
10 ms |
upper limit |
9990 s |
IEC timer |
present |
Yes; Number unlimited (limited only by work memory) |
Type |
SFB |
Data areas and their retentivity |
retentive data area in total (incl. times, counters, flags), max. |
all |
Flag |
Number, max. |
256 byte |
Retentivity available |
Yes |
Retentivity preset |
MB 0 to MB 15 |
Number of clock memories |
8; 1 memory byte |
Local data |
per priority class, max. |
510 byte |
Address area |
I/O address area |
Inputs |
1 kbyte |
Outputs |
1 kbyte |
Process image |
Inputs |
128 byte |
Outputs |
128 byte |
Digital channels |
Inputs |
8192 bits |
Outputs |
8192 bits |
Inputs, of which central |
56 byte |
Outputs, of which central |
56 byte |
Analog channels |
Inputs |
512 words |
Outputs |
512 words |
Inputs, of which central |
14 words |
Outputs, of which central |
14 words |
Hardware configuration |
Expansion modules |
Number of expansion modules, max. |
7 |
of which motor starters/frequency converters, max. |
6 |
of which pneumatic interfaces, max. |
6 |
Time of day |
Clock |
Hardware clock (real-time clock) |
Yes |
battery-backed and synchronizable |
Yes; Backup time typically 6 weeks (at 40 °C ambient temperature) |
Deviation per day, max. |
10 s |
Operating hours counter |
Number |
1 |
Number/Number range |
0 |
Range of values |
0 to 2^31 hours (when using SFC 101) |
Granularity |
1 hour |
retentive |
Yes; Must be restarted at each restart |
Clock synchronization |
supported |
Yes |
to MPI, slave |
Yes |
in AS, master |
Yes |
in AS, slave |
Yes |
1. Interface |
Interface type |
Coexistent, integrated RS 485 interface |
Physics |
RS 485 |
isolated |
Yes |
Functionality |
MPI |
Yes |
DP master |
Yes |
DP slave |
Yes; active / passive |
Point-to-point connection |
No |
MPI |
Transmission rate, max. |
12 Mbit/s |
Services |
PG/OP communication |
Yes |
Routing |
Yes |
Global data communication |
Yes |
S7 basic communication |
Yes |
S7 communication |
Yes |
S7 communication, as server |
Yes |
DP master |
Services |
PG/OP communication |
Yes |
Routing |
Yes |
Global data communication |
No |
S7 basic communication |
No |
S7 communication |
Yes |
S7 communication, as server |
Yes |
Equidistance mode support |
Yes |
SYNC/FREEZE |
Yes |
Activation/deactivation of DP slaves |
Yes |
Direct data exchange (slave-to-slave communication) |
Yes |
DPV1 |
Yes |
Address area |
Inputs, max. |
1 kbyte |
Outputs, max. |
1 kbyte |
User data per DP slave |
User data per DP slave, max. |
244 byte; 244 byte / 244 byte |
DP slave |
Number of connections |
12 |
Transmission rate, max. |
12 Mbit/s |
Address area, max. |
32 |
User data per address area, max. |
32 byte |
Services |
Routing |
Yes; with interface active |
S7 communication, as client |
No |
S7 communication, as server |
No |
Transfer memory |
Inputs |
244 byte |
Outputs |
244 byte |
Communication functions |
PG/OP communication |
Yes |
Global data communication |
supported |
Yes |
Number of GD packets, max. |
4 |
Number of GD packets, transmitter, max. |
4 |
Number of GD packets, receiver, max. |
4 |
Size of GD packets, max. |
22 byte |
Size of GD packet (of which consistent), max. |
22 byte |
S7 basic communication |
supported |
Yes |
User data per job, max. |
76 byte |
User data per job (of which consistent), max. |
76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
S7 communication |
supported |
Yes |
as server |
Yes |
as client |
No |
User data per job, max. |
180 byte; With PUT/GET |
User data per job (of which consistent), max. |
64 byte |
S5 compatible communication |
supported |
No |
Number of connections |
overall |
12 |
usable for PG communication |
|
reserved for PG communication |
1 |
adjustable for PG communication, max. |
11 |
usable for OP communication |
|
reserved for OP communication |
1 |
adjustable for OP communication, max. |
11 |
usable for S7 basic communication |
|
reserved for S7 basic communication |
10 |
adjustable for S7 basic communication, max. |
11 |
S7 message functions |
Number of login stations for message functions, max. |
12; Depending on the configured connections for PG/OP and S7 basic communication |
Process diagnostic messages |
Yes |
simultaneously active Alarm-S blocks, max. |
40 |
Test commissioning functions |
Status block |
Yes |
Single step |
Yes |
Number of breakpoints |
2 |
Status/control |
Status/control variable |
Yes |
Variables |
Inputs, outputs, memory bits, DB, times, counters |
Number of variables, max. |
30 |
of which status variables, max. |
30 |
of which control variables, max. |
14 |
Forcing |
Forcing |
Yes |
Forcing, variables |
Inputs, outputs |
Number of variables, max. |
10 |
Diagnostic buffer |
present |
Yes |
Number of entries, max. |
100 |
adjustable |
No |
Configuration |
Configuration software |
STEP 7 |
Yes; V5.2 SP1 |
Dimensions |
Width |
175 mm |
Height |
110 mm |
Depth |
90 mm |
Status |
Jul 18, 2014 |