PUSH BUTTON PANEL PP17 I 16 SHORT-STROKE KEYS 16 SURFACE LED''S, 16 DI AND 16 DO TERMINALS PROFIBUS DP12 |
Product type designation |
Control elements |
With parameterizable keys |
Yes |
With key and signal lamp test |
Yes; Automatically when switching on |
Keyboard |
● freely inscribable membrane keys |
Yes |
● Short stroke keys |
|
— Number of short-stroke keys |
16 |
Expansions for operator control of the process |
● DP direct LEDs (LEDs as S7 output I/O) |
16 |
● Number of color modes for LED |
3 |
● Direct keys (keys as S7 input I/O) |
16 |
Installation type/mounting |
Rack mounting possible |
No |
Front installation possible |
Yes |
Type of fitting, rail mounting |
No |
Wall mounting/direct mounting possible |
No |
Mounting in portrait format possible |
No |
Mounting in landscape format possible |
Yes |
Mounting technology |
Clamp terminals |
Number of slots for command devices and signaling units |
12 |
Supply voltage |
Type of supply voltage |
DC |
permissible range, lower limit (DC) |
18 V |
permissible range, upper limit (DC) |
30 V |
Input current |
Inrush current A²s |
0.03 A²·s |
Type of output |
LED colors |
Red, yellow, green |
● Red |
Yes |
● Yellow |
Yes |
● Green |
Yes |
● white |
No |
● blue |
No |
Digital inputs |
Number of digital inputs |
16 |
Input voltage |
● Rated value (DC) |
24 V |
Digital outputs |
Number of digital outputs |
16 |
Load "resistive" |
100 mA |
Load "inductive" |
100 mA; max. 2 watts |
Load "capacitive" |
100 mA; max. 2 watts |
Total power |
12 W |
Number of additional outputs |
|
● In groups of |
4 |
● Output current (per output) max. |
100 mA |
● Total current (per group), max. |
500 mA |
● short-circuit protection |
Yes |
Output voltage |
● Rated value (DC) |
24 V |
Interfaces |
PROFINET IO |
● Number of PROFINET interfaces |
0 |
Industrial Ethernet |
● Number of industrial Ethernet interfaces |
0 |
● Industrial Ethernet status LED |
0 |
● Number of ports of the integrated switch |
0 |
Protocols |
PROFINET |
No |
PROFINET IO |
No |
IRT supported |
No |
MRP supported |
No |
PROFINET CBA |
No |
Supports protocol for PROFIsafe |
No |
PROFIBUS |
Yes |
MPI |
Yes |
Protocols (Ethernet) |
● TCP/IP |
No |
Further protocols |
● AS-i |
No |
● Supports protocol for AS-Interface Safety at Work |
No |
● Supports protocol for SafetyBUS p |
No |
● CAN |
No |
● INTERBUS |
No |
● Supports protocol for INTERBUS-Safety |
No |
● EIB/KNX |
No |
● MODBUS |
No |
● Data highway |
No |
● DeviceNet |
No |
● Supports protocol for DeviceNet Safety |
No |
● Supports protocol for EtherNet/IP |
No |
● Local Operating Network |
No |
● SUCOnet |
No |
● Foundation Fieldbus |
No |
● SERCOS |
No |
● other bus systems |
No |
Test commissioning functions |
Illuminant test |
Yes |
Pushbutton and lamp test |
Yes |
EMC |
Emission of radio interference acc. to EN 55 011 |
● Limit class A, for use in industrial areas |
Yes |
● Limit class B, for use in residential areas |
No |
Degree and class of protection |
IP (at the front) |
IP65 |
Enclosure Type 4 at the front |
No |
Enclosure type 4x at the front |
No |
IP (rear) |
IP20 |
Standards, approvals, certificates |
CE mark |
Yes |
KC approval |
No |
cULus |
No |
RCM (formerly C-TICK) |
No |
Suitable for safety functions |
No |
Marine approval |
● Germanischer Lloyd (GL) |
No |
● American Bureau of Shipping (ABS) |
No |
● Bureau Veritas (BV) |
No |
● Det Norske Veritas (DNV) |
No |
● Lloyds Register of Shipping (LRS) |
No |
● Nippon Kaiji Kyokai (Class NK) |
No |
● Polski Rejestr Statkow (PRS) |
No |
Use in hazardous areas |
● ATEX Zone 2 |
No; On request |
● ATEX Zone 22 |
No; On request |
● cULus Class I Zone 1 |
No |
● cULus Class I Zone 2, Division 2 |
No |
● FM Class I Division 2 |
No |
Ambient conditions |
Mounting position |
vertical |
maximum permissible angle of inclination without external ventilation |
35° |
Operating temperature |
● Operating temperature range, min. |
0 °C |
● Operating temperature range, max. |
55 °C |
● Operation (vertical installation) |
0 °C to +55 °C |
— in vertical mounting position, minimum |
0 °C |
— in vertical mounting position, maximum |
55 °C |
● Operation (max. tilt angle) |
0 °C to +55 °C |
— at maximum tilt angle, minimum |
0 °C |
— at maximum tilt angle, maximum |
55 °C |
Storage/transport temperature |
● Min. |
-20 °C |
● max. |
60 °C |
Relative humidity |
● Operation, max. |
95 % |
Configuration |
Configuration software |
● STEP 7 Basic (TIA Portal) |
Yes |
● STEP 7 Professional (TIA Portal) |
Yes |
Functionality under WinCC (TIA Portal) |
Process coupling |
● S7-1200 |
Yes |
● S7-1500 |
Yes |
● S7-200 |
No |
● S7-300/400 |
Yes |
● LOGO! |
No |
● Win AC |
Yes |
● SINUMERIK |
No |
● SIMOTION |
No |
● Allen Bradley (EtherNet/IP) |
No |
● Allen Bradley (DF1) |
No |
● Mitsubishi (MC TCP/IP) |
No |
● Mitsubishi (FX) |
No |
● OMRON (FINS TCP) |
No |
● OMRON (LINK/Multilink) |
No |
● Modicon (Modbus TCP/IP) |
No |
● Modicon (Modbus) |
No |
Mechanics/material |
Type of housing (front) |
|
● plastic |
No |
● aluminum |
Yes |
● Stainless steel |
No |
Lifetime, typ. |
● Short-stroke keys (in switching cycles) |
1 500 000 |
● LEDs (ON period) |
100 % |
Dimensions |
Width of the housing front |
240 mm |
Height of housing front |
204 mm |
Mounting cutout/device depth (W x H x T) |
|
● Mounting cutout, width |
226 mm |
● Mounting cutout, height |
190 mm |
Device depth |
53 mm |
Weights |
Without packaging |
1 130 g |
last modified: |
14.10.2014 |