Product type designation |
CP 443-5 Extended |
|
COMMUNICATIONSPROCESSOR CP443-5 EXTENDED FOR CONNECTION OF SIMATIC S7-400 TO PROFIBUS, DP, S5 COMPATIBLE PG/OP AND S7 COMMUNICATION |
Transmission rate |
Transfer rate |
|
● at the 1st interface / acc. to PROFIBUS |
9.6 kbit/s ... 12 Mbit/s |
Interfaces |
Number of interfaces / acc. to Industrial Ethernet |
0 |
Number of electrical connections |
|
● at the 1st interface / acc. to PROFIBUS |
1 |
Design of the electrical connection |
|
● at the 1st interface / acc. to PROFIBUS |
9-pin Sub-D socket (RS485) |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage |
DC |
Supply voltage / 1 / from backplane bus |
5 V |
Supply voltage |
5 V |
Relative symmetrical tolerance / for DC |
|
● at 5 V |
5 % |
Consumed current |
|
● from backplane bus / for DC / at 5 V / typical |
1 A |
Active power loss |
5.5 W |
Permitted ambient conditions |
Ambient temperature |
|
● during operation |
0 ... 60 °C |
● during storage |
-40 ... +70 °C |
● during transport |
-40 ... +70 °C |
Relative humidity / at 25 °C / without condensation / during operation / maximum |
95 % |
Protection class IP |
IP20 |
Design, dimensions and weight |
Module format |
Compact module S7-400 single width |
Width |
25 mm |
Height |
290 mm |
Depth |
210 mm |
Net weight |
0.65 kg |
Product properties, functions, components / general |
Number of units |
|
● per CPU / maximum |
14 |
● Note |
The number of CPs that can be operated as DP masters depends on the number of CP 443-1 Advanced processors operating in the S7-400 station as PROFINET IO controllers. Up to 10 CPs can be operated in total: up to 4 as PROFINET IO controllers (CP 443-1 Advanced); up to 10 as DP masters (CP 443-5 Extended) |
Performance data |
Performance data / open communication |
Number of possible connections / for open communication / by means of SEND/RECEIVE blocks |
|
● maximum |
32 |
Amount of data |
|
● as user data per connection / for open communication / by means of SEND/RECEIVE blocks / maximum |
240 byte |
Performance data / PROFIBUS DP |
Service / as DP master |
|
● DPV1 |
Yes |
Number of DP slaves / on DP master / usable |
125 |
Amount of data |
|
● of the address area of the inputs / as DP master / total |
4096 byte |
● of the address area of the outputs / as DP master / total |
4096 byte |
● of the address area of the inputs / per DP slave |
244 byte |
● of the address area of the outputs / per DP slave |
244 byte |
Performance data / S7 communication |
Number of possible connections / for S7 communication |
|
● maximum |
48 |
Performance data / multi-protocol mode |
Number of active connections / with multi-protocol mode |
|
● without DP / maximum |
59 |
● with DP / maximum |
54 |
Performance data / telecontrol |
Protocol / is supported |
|
● TCP/IP |
No |
Product functions / management, configuration |
Configuration software |
|
● required |
STEP 7 V5.4 SP4 or higher and NCM S7 for PROFIBUS |
Further Information / Internet Links |
Internet-Link |
|
● to website: Selector SIMATIC NET SELECTION TOOL |
http://www.siemens.com/snst |
● to website: Industrial communication |
http://www.siemens.com/simatic-net |
● to website: Information and Download Center |
http://www.siemens.com/automation/net/catalog |
● to website: Image database |
http://automation.siemens.com/bilddb |
● to website: CAx Download Manager |
http://www.siemens.com/cax |
● to website: Industry Online Support |
http://support.automation.siemens.com |
last modified: |
03.11.2014 |
Date 04.11.2014 |
Changes preserved © Copyright Siemens AG 2014 |