6ES7317-2EJ10-0AB0 CPU317-2 PN/DP, 512KB

Product Code: 6ES7317-2EJ10-0AB0

Availability: In Stock

Price: $2,688.63
  
 
Artikelnummer 6ES7317-2EJ10-0AB0
General information
Hardware product version 02
Firmware version V2.3.0
Engineering with
● Programming package STEP 7 V5.3 or higher
Supply voltage
external protection for power supply lines (recommendation) 2 A min.
Memory
Backup
● present Guaranteed by MMC (maintenance-free)
● without battery Program and data
CPU-blocks
Number of blocks (total) (DBs, FCs, FBs OBs, SDBs); the maximum number of loadable blocks can be reduced by the MMC being used.
DB
● Number, max. Number band: 1 to 2047
FB
● Number, max. Number range: 0 to 2047
FC
● Number, max. Number range: 0 to 2047
OB
● Number, max. see instruction list
● Number of free cycle OBs OB 1
● Number of time alarm OBs OB 10
● Number of delay alarm OBs OB 20, 21
● Number of time interrupt OBs OB 32, 33, 34, 35
● Number of process alarm OBs OB 40
● Number of startup OBs OB 100
● Number of asynchronous error OBs OB 80
● Number of synchronous error OBs OB 121, 122
Counters, timers and their retentivity
S7 counter
of which retentive without battery
— preset Z 0 to Z 7
IEC counter
● Type SFB
● Number Unlimited (limited only by RAM capacity)
S7 times
Retentivity
— preset No retentivity
IEC timer
● Type SFB
● Number Unlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area, total All, max. 256 KB
Flag
● Retentivity available From MB 0 to MB 4095
● Retentivity preset MB 0 to MB 15
● Number of clock memories 1 memory byte
Data blocks
● Number, max. from DB 1 to DB 2047
● Retentivity adjustable via non-retain property on DB
● Retentivity preset Yes
Time of day
Clock
● Backup time At 40 °C ambient temperature
Operating hours counter
● Number/Number range 0 to 3
● Range of values 0 to 2^31 hours (when using SFC 101)
● Granularity 1 hour
● retentive Must be restarted at each restart
1. Interface
Interface type Integrated RS 485 interface
Physics RS 485
DP slave
● automatic baud rate search only with passive interface
Services
— Routing with interface active
2. Interface
Interface type PROFINET
Physics RJ45
automatic detection of transmission rate 10/100 Mbit/s
Functionality
● PROFINET IO Controller Firmware Status V2.3 or higher
PROFINET IO Controller
● Updating time 1 to 512 ms (minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the volume of configured user data)
Services
— S7 communication with loadable FBs, max. configurable connections: 16
— Open IE communication via TCP/IP
Communication functions
S7 basic communication
● User data per job (of which consistent), max. 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
● as client via integrated PROFINET interface and loadable FB or via CP and loadable FB
● User data per job, max. See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5 compatible communication
● supported via CP and loadable FC
Open IE communication
● TCP/IP via integrated PROFINET interface and loadable FBs
PROFINET CBA (at set setpoint communication load)
HMI variables via PROFINET (acyclic)
— Number of stations that can log on for HMI variables (PN OPC/iMap) 2x PN OPC/1x iMap
PROFIBUS proxy functionality
— Data length per connection, max. Slave-dependent
S7 message functions
Number of login stations for message functions, max. Depending on the configured connections for PG/OP and S7 basic communication
Test commissioning functions
Status/control
● Variables Inputs, outputs, memory bits, DB, times, counters
Forcing
● Forcing, variables Inputs, outputs
Configuration
Configuration software
● STEP 7 V5.3 or higher
Programming
● Command set see instruction list
● System functions (SFC) see instruction list
● System function blocks (SFB) see instruction list
last modified: 21.08.2014