6ES7675-3AG30-0PA0 SIMATIC MICROBOX 420-T

Product Code: 6ES7675-3AG30-0PA0

Availability: In Stock

Price: $2,759.87
Artikelnummer 6ES7675-3AG30-0PA0
SIMATIC MICROBOX 420-T, WITH SIMATIC WINAC RTX 2005 AND SIMATIC SOFTNET PG, WITH TECHNOLOGY/MOTION CONTROL-FUNC. INSTALLED READY TO RUN ON MICROBOX PC420 WITH PIII 933 MHZ, PROFIBUS DP, 512 MB RAM, 1 GB CF-CARD WINDOWS XP EMBEDDED, LANGUAGE ENGLISCH
General information
Hardware product version V1
Firmware version V1.0
PC configuration
Computer platform Microbox PC 420
Processor selection Pentium III 933 MHz
Main memory 512 Mbyte RAM
Compact Flash 1 Gbyte
Operating systems Windows XP Embedded
Installed software
● Control WinAC T V1.0
● Communication Softnet PG for IE/Simatic Net 2005 V3.0.1
Supply voltage
Rated value, 24 V DC Yes
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Mains buffering
● Mains/voltage failure stored energy time 5 ms
Input current
Rated value at 24 V DC 2 500 mA
Power
Power consumption, max. 61 W
Battery
Backup battery
● Backup time, max. 5 y
CPU processing times
for bit operations, typ. 0.004 µs
for fixed point arithmetic, typ. 0.003 µs
for floating point arithmetic, typ. 0.004 µs
CPU-blocks
DB
● Number, max. 65 535
● Size, max. 64 kbyte
FB
● Number, max. 65 536
● Size, max. 64 kbyte
FC
● Number, max. 65 536
● Size, max. 64 kbyte
OB
● Number, max. 30
● Size, max. 64 kbyte
● Number of free cycle OBs 1
● Number of time alarm OBs 1
● Number of delay alarm OBs 1
● Number of time interrupt OBs 9
● Number of process alarm OBs 1
● Number of startup OBs 1
● Number of asynchronous error OBs 7
● Number of synchronous error OBs 2
● Number of diagnostic alarm OBs 1
Nesting depth
● per priority class 24
● additional within an error OB 2
Counters, timers and their retentivity
S7 counter
● Number 512
Retentivity
— can be set Yes
— lower limit 0
— upper limit 512
— preset 8
Counting range
— can be set Yes
— lower limit 0
— upper limit 999
IEC counter
● present Yes
● Type SFB
● Number 3
S7 times
● Number 512
Retentivity
— can be set Yes
— lower limit 0
— upper limit 512
— preset 0
Time range
— lower limit 10 ms
— upper limit 6 390 s
IEC timer
● present Yes
● Type SFB
● Number 3
Data areas and their retentivity
retentive data area, total 30 KB
retentive data area in total (incl. times, counters, flags), max. 30 kbyte
Flag
● Number, max. 16 384 byte
● Number of clock memories 8
Data blocks
● Number, max. 65 535
● Size, max. 64 kbyte
● Retentivity adjustable Yes
● Retentivity preset Yes
Local data
● adjustable, max. 16 kbyte
● preset 256 byte
Address area
I/O address area
● Inputs 2 000 byte
● Outputs 2 048 byte
Process image
● Inputs 2 048 byte
● Outputs 2 048 byte
● Inputs, adjustable 2 048 kbyte
● Outputs, adjustable 2 048 kbyte
● Inputs, default 512 byte
● Outputs, default 512 byte
Default addresses of the integrated channels
— Digital outputs 66
Subprocess images
● Number of subprocess images, max. 15
Digital channels
● Inputs 16 000
● Outputs 16 376; (2048 - 1 bytes for integrated DO) * 8
Analog channels
● Inputs 1 000
● Outputs 1 023; (2048 - 1 bytes for integrated DO) / 2
● Inputs, of which central 0
● Outputs, of which central 0
Addressing volume
● Inputs 2 048 byte
● Outputs 2 048 byte
Address space per module
● Address space per module, max. 244 byte
Time of day
Clock
● Hardware clock (real-time clock) Yes
● Deviation per day, max. 5 s
● Backup time 5 y
Operating hours counter
● Number 8
● Number/Number range 0 to 7
● Range of values 32767
● Granularity 1 hour
● retentive Yes
Clock synchronization
● supported No
● to PC-CP, slave No
● to MPI, master No
● to MPI, slave No
● in AS, master No
● in AS, slave No
● on Ethernet via NTP No
Digital inputs
integrated channels (DI) 0
Digital outputs
Number of digital outputs 8
● of which high-speed outputs 8
integrated channels (DO) 8
Functions For technology functions, e.g. high-speed cam switch signals
short-circuit protection Yes
Switching capacity of the outputs
● Lamp load, max. 5 W
Output voltage
● for signal "0", max. 3 V
Output current
● for signal "1" rated value 0.5 A
● for signal "1" permissible range, min. 5 mA
● for signal "1" permissible range, max. 0.6 A
Parallel switching of 2 outputs
● for increased power No
● for redundant control of a load No
Switching frequency
● with resistive load, max. 100 Hz
● with inductive load, max. 0.2 Hz
● on lamp load, max. 10 Hz
Cable length
● Cable length, shielded, max. 25 m
● Cable length unshielded, max. 25 m
Analog inputs
Integrated channels (AI) 0
Analog outputs
Integrated channels (AO) 0
Interfaces
USB port 2xUSB 2.0 high curr./2xUSB 2.0 low curr.
serial interface COM1 (RS232)
Video interfaces
● Graphics interface DVI VGA / DVI integrated
Industrial Ethernet
● Industrial Ethernet interface 2x VUA VT6105L OM/VT6106S, 10/100 Mbit/s with RJ45
1st interface
Physics RS 485
Isolated Yes
Functionality
● MPI No
● DP master Yes
● DP slave No
● Point-to-point connection No
DP master
● Number of connections, max. 14
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 32
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
— Equidistance mode support No
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV1 Yes
User data per DP slave
— User data per DP slave, max. 244 byte
— Inputs, max. 244 byte
— Outputs, max. 244 byte
2nd interface
Physics RS 485
Isolated Yes
Automatic detection of transmission speed Yes
Functionality
● MPI No
● DP master Yes
● DP slave No
● PROFINET IO Controller No
● PROFINET CBA No
● Point-to-point connection No
DP master
● Number of connections, max. 0
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 32
Services
— PG/OP communication No
— Routing Yes
— Global data communication No
— S7 basic communication No
— S7 communication No
— S7 communication, as client No
— S7 communication, as server No
— Equidistance mode support Yes
— SYNC/FREEZE No
— Activation/deactivation of DP slaves No
— Direct data exchange (slave-to-slave communication) No
— DPV1 Yes
User data per DP slave
— User data per DP slave, max. 244 byte
— Inputs, max. 244 byte
— Outputs, max. 244 byte
Communication functions
PG/OP communication Yes
Global data communication
● supported No
S7 basic communication
● supported No
S7 communication
● supported Yes
● as server Yes
● As client Yes
● User data per job, max. 64 kbyte
S7 message functions
Number of login stations for message functions, max. 32
Process diagnostic messages Yes
simultaneously active Alarm-S blocks, max. 200
Test commissioning functions
Status block Yes
Single step Yes
Number of breakpoints 20
Status/control
● Status/control variable Yes
● Variables E/A/M/DB/Z/T
Forcing
● Forcing No
Diagnostic buffer
● present Yes
● Number of entries, max. 120
— can be set Yes
— preset 120
Interrupts/diagnostics/status information
Alarms
● Alarms No
Diagnostic messages
● Diagnostic functions No
Diagnostics indication LED
● Status indicator digital output (green) No
● Status indicator digital input (green) No
Degree and class of protection
Degree of protection to EN 60529
● IP20 Yes
Standards, approvals, certificates
CE mark Yes
CSA approval Yes
cULus Yes
RCM (formerly C-TICK) Yes
FM approval No
Ambient conditions
Operating temperature
● Min. 0 °C
● max. 50 °C
Storage/transport temperature
● Min. -20 °C
● max. 60 °C
Vibrations
● Operation, checked according to IEC 60068-2-6 Yes; 10 to 58 Hz: Amplitude 0.075 mm; 58 to 500 Hz: Acceleration 9.8 m/s2
● Transport tested checked to IEC 60068-2-6 Yes; 5 to 9 Hz: 3.5 mm; 9 to 500 Hz: 9.8 m/s2
Shock test
● checked according to IEC 60068-2-27 Yes; 150 m/s2, 11 ms;
● checked according to IEC 60068-2-29 Yes; 150 m/s2, 11 ms;
Shock testing
● checked according to IEC 60068-2-29 Yes; 150 m/s2, 11 ms;
● Operation, checked according to IEC 60068-2-29 Yes; 150 m/s2, 11 ms;
Configuration
Configuration software
● STEP 7 Yes; Step 7 V5.3 SP3 or higher and S7-Technology option package V3.0 SP1
programming
● Command set see instruction list
● Nesting levels 8
● System functions (SFC) See manual
● System function blocks (SFB) See manual
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Software libraries
— Process diagnostics Yes
— Software controller Yes
Know-how protection
● User program protection/password protection Yes
Cycle time monitoring
● lower limit 1 ms
● upper limit 6 000 ms
● can be set Yes
● preset 6 000 ms
Technology objects
● Number of technology objects, total 64
— of which axes 32
— of which output cams 32
— of which cam disks 32
● Number of probes 16
● Number of external encoders 16
Dimensions
Width 262 mm
Height 133 mm
Depth 65 mm
last modified: 14.10.2014