6ES7671-0RC06-0YA0 SIMATIC WINAC RTX 2008

Product Code: 6ES7671-0RC06-0YA0

Availability: In Stock

Price: $842.55
Artikelnummer 6ES7671-0RC06-0YA0
SIMATIC WINAC RTX 2008, SINGLE LICENSE F. 1 INSTALL., R-SW, SW AND DOCU. ON DVD, LICENSE KEY ON USB STICK, CLASS A, 3 LANGUAGES (D,E,F), EXECUTABLE UNDER WIN XP SP2 AND ARDENCE RTX, REFERENCE-HW: SIMATIC PC
General information
Hardware product version -
Firmware version 4,4
Engineering with
● Programming package STEP7 V5.4 SP4 or higher + HW update / iMap V3.0 SP1
Memory
Work memory
● Integrated PC RAM can be used (non-paged memory)
Load memory
● integrated RAM, max. PC RAM can be used (non-paged memory)
CPU processing times
for bit operations, typ. 0.004 µs; Typical
for fixed point arithmetic, typ. 0.003 µs; Typical
for floating point arithmetic, typ. 0.004 µs; Typical
Reference platform Pentium 4, 2.4 GHz
CPU-blocks
DB
● Number, max. Limited only by available PC work memory
● Size, max. 64 kbyte
FB
● Number, max. Limited only by available PC work memory
● Size, max. 64 kbyte
FC
● Number, max. Limited only by available PC work memory
● Size, max. 64 kbyte
OB
● Number, max. Limited only by available PC work memory
● Size, max. 64 kbyte
● Number of free cycle OBs 1; OB 1
● Number of time alarm OBs 1; OB 10
● Number of delay alarm OBs 1; OB 20
● Number of time interrupt OBs 9; OB 30-38
● Number of process alarm OBs 1; OB 40
● Number of ODK OBs 3; OB 52-54
● Number of DPV1 alarm OBs 3; OB 55-57
● Number isochronous mode OBs 2; OB 61-62
● Number of startup OBs 2; OB 100, 102
● Number of asynchronous error OBs 7; OB 80, 82-85, 86, 88
● Number of synchronous error OBs 2; OB 121, 122
Nesting depth
● per priority class 24
● additional within an error OB 24
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2 047
— preset 8
Counting range
— can be set Yes
— lower limit 0
— upper limit 999
IEC counter
● present Yes
● Type SFB
S7 times
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2 047
— preset 0
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
● Type SFB
Data areas and their retentivity
Retentivity without UPS and PS Extension Board 128 KB with SIMATIC Microbox PC 427B and Panel PC 477B; other SIMATIC PCs on request
Retentivity with UPS all data
Flag
● Number, max. 16 kbyte
● of which retentive MB 0 to MB 16383
● Retentivity preset MB 0 to MB 15
● Number of clock memories 8
Address area
I/O address area
● Inputs 16 kbyte
● Outputs 16 kbyte
of which, distributed
— DP interface, inputs 16 kbyte
— DP interface, outputs 16 kbyte
— PN interface, inputs 16 kbyte
— PN interface, outputs 16 kbyte
Process image
● Inputs, adjustable 8 kbyte
● Outputs, adjustable 8 kbyte
● Inputs, default 512 byte
● Outputs, default 512 byte
Subprocess images
● Number of subprocess images, max. 15
Digital channels
● Inputs 128 000
● Outputs 128 000
Analog channels
● Inputs 8 000
● Outputs 8 000
Hardware configuration
Submodules
● Number of submodules, max 4
● of which PROFIBUS, max. 4; CP 5611, CP 5611-A2, integrated PROFIBUS interface of the SIMATIC PC, CP 5613 CP, 5613-A2, CP 5603
● of which Industrial Ethernet, max. 1; PROFINET: CP1616, CP1604, S7-mEC integrated PROFINET interface and SIMATIC PC
Number of operable FMs and CPs (recommended)
● FM 4; FM distributed: FM 350-1 / 350-2, FM 351, FM 352, FM 353, FM 355 / 355-2
● CP, point-to-point 2; CP 340, CP 341 distributed
● CP, LAN Over PC CP
Time of day
Clock
● Hardware clock (real-time clock) Yes
● battery-backed and synchronizable Yes
Clock synchronization
● supported Yes
● to PC-CP, slave Yes
● on Ethernet via NTP Yes
Interfaces
1st interface
Interface type CP 5611, CP 5611-A2, integrated PROFIBUS interface of the SIMATIC PC
Max. no. of simultaneously operable CPs 1
Physics RS 485 / PROFIBUS
Isolated Yes
Power supply to interface (15 to 30 V DC), max. no supply to externally connected devices
Functionality
● MPI No
● DP master Yes
● DP slave No
DP master
● Number of connections, max. 8
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 64
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— Equidistance mode support Yes; Only in conjunction with isochronous mode
— Isochronous mode Yes
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV0 Yes
— DPV1 Yes
Address area
— Inputs, max. 16 kbyte
— Outputs, max. 16 kbyte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
2nd interface
Interface type CP 5613, CP 5613-A2
Max. no. of simultaneously operable CPs 4
Physics RS 485 / PROFIBUS
Isolated Yes
Power supply to interface (15 to 30 V DC), max. no supply to externally connected devices
Functionality
● MPI No
● DP master Yes
● DP slave No
DP master
● Number of connections, max. 50
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 125
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— Equidistance mode support Yes; Only in conjunction with isochronous mode
— Isochronous mode Yes
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV0 Yes
— DPV1 Yes
Address area
— Inputs, max. 16 kbyte
— Outputs, max. 16 kbyte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
3rd interface
Interface type PROFINET
Max. no. of simultaneously operable CPs 1; Intel Pro/1000 (Intel 82573L, 82541PI; non-shared IRQ required); integrated IE interface SIMATIC PC 4x7B, 6x7B, 8x7B
Physics Ethernet
Isolated Yes
Automatic detection of transmission speed Yes; 10/100 Mbit/s
Functionality
● PROFINET IO Controller Yes
● PROFINET IO Device No
● PROFINET CBA Yes
● Open IE communication Yes
● Web server No
PROFINET IO Controller
● Transmission rate, min. 10 Mbit/s; 100 Mbit/s, if PROFINET IO-Controller configured
● Transmission rate, max. 100 Mbit/s
● Number of connectable IO devices, max. 128
● IRT, supported No
● Prioritized startup supported Yes
— Number of IO Devices, max. 32
● Activation/deactivation of IO Devices Yes
● IO Devices changing during operation (partner ports), supported Yes
● Device replacement without swap medium Yes
● Send cycles 1 - 512 ms
● Updating time 1 - 512 ms (minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the volume of configured user data)
Services
— PG/OP communication Yes
— Routing Yes; S7 routing
— S7 communication Yes
— Open IE communication Yes
Address area
— Inputs, max. 16 kbyte
— Outputs, max. 16 kbyte
— User data per address area, max. 2 kbyte
— User data consistency, max. 256 byte
PROFINET CBA
● acyclic transmission Yes
● Cyclic transmission Yes
SIMATIC communication
● PG/OP communication Yes
● S7 routing Yes
● S7 communication Yes
● Number of connections, max. 16
Open IE communication
● Open IE communication, supported Yes
● Number of connections, max. 32
4th interface
Interface type PROFINET
Max. no. of simultaneously operable CPs 1; CP 1616 (HW release 8 or above), CP 1604 (HW release 7 or higher), integrated PROFINET interface of SIMATIC PC and S7-mEC
Physics Ethernet
Isolated Yes
Automatic detection of transmission speed Yes; 10/100 Mbit/s
Functionality
● PROFINET IO Controller Yes
● PROFINET CBA Yes
● Open IE communication Yes
● Web server No
PROFINET IO Controller
● Transmission rate, max. 100 Mbit/s
● Number of connectable IO devices, max. 256
● Number of IO devices with IRT and the option "high flexibility" 64
— of which in line, max. 32
● IRT, supported Yes
● Prioritized startup supported Yes
— Number of IO Devices, max. 32
● Activation/deactivation of IO Devices Yes
— Maximum number of IO devices that can be activated/deactivated at the same time. 8
● IO Devices changing during operation (partner ports), supported Yes
● Device replacement without swap medium Yes
● Send cycles 250 µs, 500 µs, 1 ms
● Updating time 0.25...512 depending on the send cycle
Services
— PG/OP communication Yes
— Routing Yes; S7 routing
— S7 communication Yes
— Open IE communication Yes
Address area
— Inputs, max. 16 kbyte
— Outputs, max. 16 kbyte
— User data per address area, max. 2 kbyte
— User data consistency, max. 256 byte
SIMATIC communication
● PG/OP communication Yes
● S7 routing Yes
● S7 communication Yes
● Number of connections, max. 32
Open IE communication
● Open IE communication, supported Yes
● Number of connections, max. 16
Isochronous mode
Isochronous operation (application synchronized up to terminal) Yes; only PROFIBUS
Number of DP masters with isochronous mode 2
User data per isochronous slave, max. 128 byte
equidistance Yes
shortest clock pulse 2.2 ms; 2.2 ms without partial process image; 2.2 ms with partial process image
Communication functions
PG/OP communication Yes
Global data communication
● supported No
S7 basic communication
● supported No
S7 communication
● supported Yes
● as server Yes
● As client Yes
Open IE communication
● TCP/IP Yes
— Number of connections, max. Dependent on interface
— Data length, max. 8 192 byte
● ISO-on-TCP (RFC1006) No
● UDP Yes
— Number of connections, max. Dependent on interface
— Data length, max. 1 472 byte
Web server
● supported No
PROFINET CBA (at set setpoint communication load)
● Setpoint for the CPU communication load 20 %
● Number of remote interconnection partners 64
● Number of functions, master/slave 30
● Total of all Master/Slave connections 1 000
● Data length of all incoming connections master/slave, max. 6 800 byte
● Data length of all outgoing connections master/slave, max. 6 800 byte
● Number of device-internal and PROFIBUS interconnections 500
● Data length of device-internal und PROFIBUS interconnections, max. 4 000 byte
● Data length per connection, max. 1 400 byte
Remote interconnections with acyclic transmission
— Sampling frequency: Sampling time, min. 500 ms
— Number of incoming interconnections 100
— Number of outgoing interconnections 100
— Data length of all incoming interconnections, max. 2 000 byte
— Data length of all outgoing interconnections, max. 2 000 byte
— Data length per connection, max. 1 400 byte
Remote interconnections with cyclic transmission
— Transmission frequency: Transmission interval, min. 10 ms
— Number of incoming interconnections 200
— Number of outgoing interconnections 200
— Data length of all incoming interconnections, max. 4 800 byte
— Data length of all outgoing interconnections, max. 4 800 byte
— Data length per connection, max. 250 byte
HMI variables via PROFINET (acyclic)
— Number of stations that can log on for HMI variables (PN OPC/iMap) 3
— HMI variable updating 500 ms
— Number of HMI variables 200
— Data length of all HMI variables, max. 2 000 byte
PROFIBUS proxy functionality
— supported Yes
— Number of linked PROFIBUS devices 16
— Data length per connection, max. 240 byte; Slave-dependent
Number of connections
● overall 64
● usable for PG communication
— reserved for PG communication 1
● usable for OP communication
— reserved for OP communication 1
S7 message functions
Number of login stations for message functions, max. 62
SCAN procedure No
Process diagnostic messages Yes; ALARM_S, ALARM_SQ
simultaneously active Alarm-S blocks, max. 20; of a total of 20 for all SFCs
Alarm 8-blocks Yes
● Number of instances for alarm 8 and S7 communication blocks, max. 600
Process control messages No
Test commissioning functions
Status block Yes
Single step Yes
Status/control
● Status/control variable Yes
Forcing
● Forcing No
Diagnostic buffer
● present Yes
● Number of entries, max.
— preset 120
Hardware requirements
Hardware required PC with color monitor, keyboard, mouse or pointing device for Windows
Main memory, min. 1 Gbyte
Required memory on hard disk, min. 100 Mbyte
Processor Intel Celeron M, 900 MHz or compatible
● Multi-processor system Yes; Dual Pentium, CoreDuo, Core2Duo or compatible
● Hyper-threading Yes
Operating systems
Configuration
Configuration software
● STEP 7 Yes; V5.4, SP4 or higher, Engineering Tools (optional)
programming
● Nesting levels 8
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Software libraries
— Easy Motion Control Yes
— Software redundancy Yes; As of V1.2, only operation of WinAC RTX with WinAC RTX
Number of simultaneously active SFCs
— DPSYC_FR 20; of a total of 20 for all SFCs
— D_ACT_DP 20; of a total of 20 for all SFCs
— RD_REC 20; of a total of 20 for all SFCs
— WR_REC 20; of a total of 20 for all SFCs
— WR_PARM 20; of a total of 20 for all SFCs
— PARM_MOD 20; of a total of 20 for all SFCs
— WR_DPARM 20; of a total of 20 for all SFCs
— DPNRM_DG 20; of a total of 20 for all SFCs
— RDSYSST 20; of a total of 20 for all SFCs
Number of simultaneously active SFBs
— RD_REC 20; of a total of 20 for all SFBs
— WR_REC 20; of a total of 20 for all SFBs
Know-how protection
● User program protection/password protection Yes
Open Development interfaces
● CCX (Custom Code Extension) Yes; WinAC ODK V4.1 or higher
● CMI (Controller Management Interface) Yes; WinAC ODK V4.1 or higher
● SMX (Shared Memory Extension) Yes; WinAC ODK V4.1 or higher
— Inputs 4 kbyte
— Outputs 4 kbyte
Weights
Weight, approx. 100 g; With packaging
last modified: 14.10.2014