SIMATIC WINAC BASIS V4.0, SINGLE LICENSE F. 1 INSTALL., R-SW, SW AND DOCU. ON CD, LICENSE KEY ON FD, CLASS A, 3 LANGUAGES (G,E,F), EXECUTABLE UNDER WIN 2000/XP, REFERENCE-HW: SIMATIC PC |
Memory |
Work memory |
● Integrated |
PC RAM can be used |
Load memory |
● integrated RAM, max. |
PC RAM can be used |
CPU processing times |
for bit operations, typ. |
0.2 µs; (typ.), reference platform Pentium 400 MHz |
for fixed point arithmetic, typ. |
0.06 µs; (typ.), reference platform Pentium 400 MHz |
for floating point arithmetic, typ. |
0.13 µs; (typ.), reference platform Pentium 400 MHz |
CPU-blocks |
DB |
● Number, max. |
Limited only by available PC work memory |
● Size, max. |
64 kbyte |
FB |
● Number, max. |
Limited only by available PC work memory |
● Size, max. |
64 kbyte |
FC |
● Number, max. |
Limited only by available PC work memory |
● Size, max. |
64 kbyte |
OB |
● Size, max. |
64 kbyte |
● Number of time alarm OBs |
1 |
● Number of delay alarm OBs |
1 |
● Number of time interrupt OBs |
5 |
● Number of process alarm OBs |
1 |
Nesting depth |
● per priority class |
24 |
● additional within an error OB |
24 |
Counters, timers and their retentivity |
S7 counter |
● Number |
512 |
Retentivity |
— can be set |
Yes |
— lower limit |
0 |
— upper limit |
511 |
— preset |
8 |
Counting range |
— can be set |
Yes |
— lower limit |
1 |
— upper limit |
999 |
IEC counter |
● present |
Yes |
● Type |
SFB |
S7 times |
● Number |
512 |
Retentivity |
— lower limit |
511 |
— upper limit |
0 |
Time range |
— lower limit |
10 ms |
— upper limit |
9 990 s |
IEC timer |
● present |
Yes |
● Type |
SFB |
Data areas and their retentivity |
Retentivity without UPS and PS Extension Board |
none |
Retentivity with UPS |
all data |
Flag |
● Number, max. |
2 kbyte |
● of which retentive |
MB 0 to MB 2047 |
● Retentivity preset |
16 |
● Number of clock memories |
8 |
Address area |
I/O address area |
● Inputs |
16 kbyte |
● Outputs |
16 kbyte |
of which, distributed |
— MPI/DP interface, inputs |
1 kbyte |
— MPI/DP interface, outputs |
1 kbyte |
— DP interface, inputs |
16 kbyte; Via CP 5613 |
— DP interface, outputs |
16 kbyte; Via CP 5613 |
Process image |
● Inputs, adjustable |
8 kbyte |
● Outputs, adjustable |
8 kbyte |
● Inputs, default |
512 byte |
● Outputs, default |
512 byte |
Subprocess images |
● Number of subprocess images, max. |
15 |
Digital channels |
● Inputs |
131 072 |
● Outputs |
131 072 |
Analog channels |
● Inputs |
8 192 |
● Outputs |
8 192 |
Hardware configuration |
Number of DP masters |
● overall |
4 |
● Integrated |
1; via CP 5611/integrated DP interface of the SIMATIC PC |
● Via CP |
4; CP 5613 |
Number of operable FMs and CPs (recommended) |
● FM |
FM distributed: FM 350-1 / 350-2, FM 351, FM 352 |
● CP, point-to-point |
CP 340, CP 341 supports the necessary mechanisms |
● CP, LAN |
Over PC CP |
Time of day |
Clock |
● Hardware clock (real-time clock) |
Yes |
● battery-backed and synchronizable |
Yes |
Interfaces |
1st interface |
Interface type |
CP 5611, SIMATIC PC integrated |
Physics |
RS 485 / PROFIBUS |
Isolated |
Yes |
Functionality |
● MPI |
No |
● DP master |
Yes |
● DP slave |
No |
DP master |
● Number of connections, max. |
8 |
● Transmission rate, max. |
12 Mbit/s |
● Number of DP slaves, max. |
32 |
Services |
— PG/OP communication |
Yes |
— Routing |
Yes |
— S7 communication |
Yes |
— Equidistance mode support |
No |
— SYNC/FREEZE |
Yes |
— Activation/deactivation of DP slaves |
Yes |
— Direct data exchange (slave-to-slave communication) |
No |
— DPV0 |
Yes |
— DPV1 |
No |
Address area |
— Inputs, max. |
16 kbyte |
— Outputs, max. |
16 kbyte |
User data per DP slave |
— User data per DP slave, max. |
244 byte; 244 byte / 244 byte |
2nd interface |
Interface type |
CP 5613 |
Physics |
RS 485 / PROFIBUS |
Isolated |
Yes |
Functionality |
● MPI |
No |
● DP master |
Yes |
● DP slave |
No |
DP master |
● Number of connections, max. |
32 |
● Transmission rate, max. |
12 Mbit/s |
● Number of DP slaves, max. |
125 |
Services |
— PG/OP communication |
Yes |
— Routing |
Yes |
— S7 communication |
Yes |
— Equidistance mode support |
Yes |
— SYNC/FREEZE |
Yes |
— Activation/deactivation of DP slaves |
Yes |
— Direct data exchange (slave-to-slave communication) |
No |
— DPV0 |
Yes |
— DPV1 |
Yes |
Address area |
— Address area, max. |
16 kbyte; 16 KB /16 KB |
User data per DP slave |
— User data per DP slave, max. |
244 byte; 244 byte / 244 byte |
Isochronous mode |
Isochronous operation (application synchronized up to terminal) |
No |
Communication functions |
PG/OP communication |
Yes |
Global data communication |
● supported |
No |
S7 basic communication |
● supported |
No |
S7 communication |
● as server |
Yes |
● As client |
Yes |
Number of connections |
● overall |
64 |
● usable for PG communication |
|
— reserved for PG communication |
1 |
● usable for OP communication |
|
— reserved for OP communication |
1 |
S7 message functions |
Number of login stations for message functions, max. |
64 |
Process diagnostic messages |
Yes; Alarm_S |
Test commissioning functions |
Status block |
Yes |
Single step |
Yes |
Status/control |
● Status/control variable |
Yes |
Forcing |
● Forcing |
No |
Diagnostic buffer |
● present |
Yes |
● Number of entries, max. |
|
— preset |
120 |
Hardware requirements |
Hardware required |
Accessories: color monitor, keyboard, mouse or pointer for Windows |
Main memory, min. |
128 Mbyte |
Required memory on hard disk, min. |
100 Mbyte |
Processor |
Intel Pentium 800 MHz |
Operating systems |
Configuration |
Software interface |
C/C++ with WinAC ODK V4.0 |
Configuration software |
● STEP 7 |
Yes; V5.2 or higher |
programming |
● Nesting levels |
8 |
Programming language |
— LAD |
Yes |
— FBD |
Yes |
— STL |
Yes |
— SCL |
Yes |
— CFC |
Yes |
— GRAPH |
Yes |
— HiGraph® |
Yes |
Software libraries |
— Easy Motion Control |
Yes |
Know-how protection |
● User program protection/password protection |
No |
last modified: |
14.10.2014 |