Operator control and monitoring |
Alarms |
Fault messages, operating messages (no buffer) |
Operating / fault messages |
● Operating messages |
|
— Operating messages, max. |
total number of operation and fault messages |
— Number of entries in operational log, max. |
not retentive |
● Fault messages |
|
— Number of fault message, max. |
total number of operation and fault messages |
— Number of entries in fault message buffer, max. |
not retentive |
Recipes |
● Data records per recipe, max. |
limited due to storage medium |
● Recipe data memory, max. |
expandable using Compact Flash Card (CF-Card) |
Display |
Design of display |
STN, CCFL backlit, 5.7" blue mode (4 blue tones) |
Control elements |
Keyboard |
● Type |
Touch (resistive/analog) |
Input current |
Current consumption, typ. |
idling |
Inrush current, max. |
for 70 ms |
Digital outputs |
● from load voltage L+, max. |
per group |
Memory |
Compact Flash Card |
Optional |
Backup |
● present |
Guaranteed by MMC (maintenance-free) |
CPU-blocks |
DB |
● Number, max. |
DB 0 reserved |
FB |
● Number, max. |
see instruction list |
FC |
● Number, max. |
see instruction list |
OB |
● Number, max. |
see instruction list |
Counters, timers and their retentivity |
S7 counter |
Retentivity |
— preset |
Z 0 to Z 7 |
IEC counter |
● Type |
SFB |
● Number |
Unlimited (limited only by RAM capacity) |
S7 times |
Retentivity |
— preset |
No retentivity |
IEC timer |
● Type |
SFB |
● Number |
Unlimited (limited only by RAM capacity) |
Data areas and their retentivity |
retentive data area in total (incl. times, counters, flags), max. |
all |
Flag |
● Retentivity preset |
MB 0 to MB 15 |
● Number of clock memories |
1 memory byte |
Address area |
Process image |
Default addresses of the integrated channels |
— Digital inputs |
124.0 to 126.7 |
— Digital outputs |
124.0 to 125.7 |
— Analog inputs |
752 to 761 |
— Analog outputs |
752 to 755 |
Hardware configuration |
Rack |
● Modules per rack, max. |
4 in subrack 0; 8 in subracks 1 and 2; 7 in subrack 3 |
Time of day |
Clock |
● Backup time |
At 40 °C ambient temperature |
Operating hours counter |
● Number/Number range |
0 |
● Range of values |
0 to 2^31 hours (when using SFC 101) |
● Granularity |
1 hour |
● retentive |
Must be restarted at each restart |
Digital inputs |
Input voltage |
● for signal "0" |
-3 to +5V |
● for signal "1" |
15 to 30 V |
Input delay (for rated value of input voltage) |
for standard inputs |
— Parameterizable |
0.1 / 0.5 / 3 / 15 ms |
Cable length |
● Cable length, shielded, max. |
100 m for technological functions |
Technological functions |
— shielded, max. |
at maximum count frequency |
— Unshielded, max. |
Unshielded cables are not permissible for technological functions |
Digital outputs |
short-circuit protection |
Clocked electronically |
● Response threshold, typ. |
1 A |
Limitation of inductive shutdown voltage to |
L+ (-48 V) |
Output voltage |
● for signal "1", min. |
L+ (-0.8 V) |
Analog inputs |
Integrated channels (AI) |
and 1x PT100 |
permissible input frequency for current input (destruction limit), max. |
continuous, max. 24 V momentarily |
permissible input voltage for voltage input (destruction limit), max. |
Permanent |
permissible input current for voltage input (destruction limit), max. |
Permanent |
permissible input current for current input (destruction limit), max. |
Permanent |
Technical unit for temperature measurement adjustable |
Degrees Celsius / degrees Fahrenheit / Kelvin |
Input ranges (rated values), resistors |
● Measured current, typ. |
1.8 to 3.3 mA |
Characteristic linearization |
● Parameterizable |
by software |
— for resistance thermometer |
Pt 100 |
Analog outputs |
Connection of actuators |
● for voltage output two-wire connection |
Without compensation of the line resistances |
Destruction limits against externally applied voltages and currents |
● Voltages at the outputs towards MANA |
Permanent |
● Current, max. |
Permanent |
Analog value creation |
Measurement principle |
Actual value encryption (successive approximation) |
Integration and conversion time/resolution per channel |
● Integration time, parameterizable |
2,5 / 16,6 / 20 ms |
Encoder |
Connection of signal encoders |
● for current measurement as 2-wire transducer |
with external supply |
● for resistance measurement with two-wire connection |
Without compensation of the line resistances |
Interfaces |
Number of printer interfaces |
serial |
1st interface |
Interface type |
Integrated RS 485 interface |
Physics |
RS 485 |
MPI |
Services |
— S7 communication, as client |
Via CP and loadable FB |
2nd interface |
Interface type |
Integrated RS 485 interface |
Physics |
RS 485 |
Number of connection resources |
12 |
DP master |
● Number of connections (of which reserved), max. |
1 for PG, 1 for OP |
DP slave |
Services |
— Routing |
Only with active interface |
Communication functions |
S7 basic communication |
● User data per job (of which consistent), max. |
76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
S7 communication |
● As client |
Via CP and loadable FB |
● User data per job, max. |
With PUT/GET |
S5-compatible communication |
● supported |
Via CP and loadable FB |
Number of connections |
● Number of logical connections (also in network), max. |
1 fixed with integral CPU |
S7 message functions |
Number of login stations for message functions, max. |
Depending on the configured connections for PG/OP and S7 basic communication |
Test commissioning functions |
Status/control |
● Variables |
Inputs, outputs, memory bits, DB, times, counters |
Integrated Functions |
Number of frequency meters |
Frequency meter up to max. 60 kHz |
Integrated function blocks (closed-loop control) |
PID controller |
Number of pulse outputs |
Pulse outputs up to 2.5 kHz |
Galvanic isolation |
Galvanic isolation analog inputs |
● Galvanic isolation analog inputs |
common for analog I/O |
Galvanic isolation analog outputs |
● Galvanic isolation analog outputs |
common for analog I/O |
Permissible potential difference |
between different circuits |
75 VDC / 60 VAC |
between inputs and MANA (UCM) |
8 V DC |
between MANA and M internally (UISO) |
75 VDC / 60 VAC |
Isolation |
Isolation checked with |
500 V DC |
EMC |
Interference immunity against discharge of static electricity |
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 |
±6 kV contact discharge acc. to IEC 61000-4-2, ESD; ±8 kV air discharge acc. to IEC 61000-4-2, ESD |
Interference immunity to cable-borne interference |
● Interference immunity on signal lines acc. to IEC 61000-4-4 |
±2 kV to IEC 61000-4-4, Burst |
Surge immunity |
● on the supply lines acc. to IEC 61000-4-5 |
Surge measurements with additional protection elements: ±1 kV (to IEC 61000-4-5; µs pulse / line to line);±2 kV (to IEC 61000-4-5; µs pulse / line to ground) |
Immunity against high-frequency electromagnetic fields |
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-3 |
10 V/m, with 80% amplitude modulation at 1 kHz, 80 MHz to 1 GHz (to IEC 61000-4-3); 10 V/m, pulse-modulated 50% duty cycle at 900 MHz and 1.89 GHz (to IEC61000-4-3) |
Immunity against conducted interference induced by high-frequency fields |
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 |
10 V/m, with 80% amplitude modulation at 1 kHz, 10 kHz to 80 MHz (acc. to IEC 61000-4-6) |
Degree and class of protection |
Degree of protection to EN 60529 |
|
● IP20 |
Housing |
● IP65 |
Front |
Ambient conditions |
Environmental conditions |
Not suitable for open-air use |
Vibrations |
● Operation, checked according to IEC 60068-2-6 |
10 to 58 Hz: Amplitude 0.075 mm; 58 to 150 Hz: Acceleration 9.8 m/s2 |
● Transport tested checked to IEC 60068-2-6 |
5 to 9 Hz: amplitude 3.5 mm; 9 to 500 Hz: acceleration 9.8 m/s (storage/transport in the packaging) |
Shock test |
● checked according to IEC 60068-2-27 |
IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms |
Shock testing |
● Operation, checked according to IEC 60068-2-29 |
Half-sine: 150 m/s2 (15 g), 11 ms, 18 shocks |
● Storage/transport, checked to IEC 60068-2-29 |
250 m/s2 (25 g), 6 ms, 1000 shocks |
Fire resistance |
● Terminal strips |
FV2 (tested to IEC 60707) |
● Basic performance in housing |
FV0 |
Configuration |
Configuration software |
● STEP 7 |
V5.1 SP3, STEP 7 Lite |
● ProTool |
or SIMATIC ProTool/Pro Configuration, Version 6.0 SP1 or higher |
● ProTool/Pro |
Configuration also with WinCC flexible |
programming |
● Command set |
see instruction list |
● System functions (SFC) |
see instruction list |
● System function blocks (SFB) |
see instruction list |
last modified: |