![](/image/data/SIEMENS_Original/6ES7/613/6ES7613-1CA01-0AE3/6ES76131CA010AE3.jpg) |
SIMATIC C7-613, COMPACT UNIT WITH 4 LINE DISPLAY, KEYS AND S7-300 CPU313C WITH 24 DI, 16 DO, 5 AI, 2 AO; MICRO MEMORY CARD AND CONNECTOR SET REQUIRED |
Operator control and monitoring |
Password protection |
Yes |
Info texts |
Yes; 128 |
Alarms |
Yes; with buffer |
Graphics object |
● Graphics object |
Yes |
Process images |
● Number of process images |
128 |
● Number of variables per image, max. |
8 |
Display |
Design of display |
LCD backlit |
Line display |
|
● Number of lines |
4 |
● Number of characters per line |
20 |
Backlighting |
● MTBF backlighting (at 20 °C) |
100 000 h |
Control elements |
Keyboard |
● Number of function keys |
10; Can be used simultaneously as numeric input |
● Number of softkeys |
4 |
Supply voltage |
24 V DC |
Yes |
permissible range, lower limit (DC) |
20.4 V |
permissible range, upper limit (DC) |
28.8 V |
Load voltage L+ |
● Rated value (DC) |
24 V |
● permissible range, lower limit (DC) |
20.4 V |
● permissible range, upper limit (DC) |
28.8 V |
Input current |
Current consumption, typ. |
350 mA; idling |
Inrush current, max. |
2 A; for 70 ms |
Power losses |
Power loss, typ. |
11 W |
Memory |
Micro Memory Card |
Yes; All data located on MMC of the CPU |
Work memory |
● Integrated |
32 kbyte; For program and data |
● expandable |
No |
Load memory |
● pluggable (MMC) |
Yes |
● pluggable (MMC), max. |
8 Mbyte |
Backup |
● present |
Yes; Guaranteed by MMC (maintenance-free) |
● without battery |
Yes; Program and data |
CPU processing times |
for bit operations, typ. |
0.1 µs |
for bit operations, max. |
0.2 µs |
for word operations, typ. |
0.2 µs |
for fixed point arithmetic, typ. |
2 µs |
for floating point arithmetic, typ. |
3 µs |
CPU-blocks |
DB |
● Number, max. |
127; DB 0 reserved |
● Size, max. |
16 kbyte |
FB |
● Number, max. |
128 |
● Size, max. |
16 kbyte |
FC |
● Number, max. |
128 |
● Size, max. |
16 kbyte |
OB |
● Size, max. |
16 kbyte |
● Number of time alarm OBs |
1 |
● Number of delay alarm OBs |
1 |
● Number of time interrupt OBs |
1 |
● Number of process alarm OBs |
1 |
Nesting depth |
● per priority class |
6 |
● additional within an error OB |
4 |
Counters, timers and their retentivity |
S7 counter |
● Number |
256 |
of which retentive without battery |
— can be set |
Yes |
— lower limit |
0 |
— upper limit |
256 |
Counting range |
— lower limit |
0 |
— upper limit |
999 |
IEC counter |
● present |
Yes |
● Type |
SFB |
S7 times |
● Number |
256 |
of which retentive without battery |
— can be set |
Yes |
— lower limit |
0 |
— upper limit |
256 |
Time range |
— lower limit |
10 ms |
— upper limit |
9 990 s |
IEC timer |
● present |
Yes |
● Type |
SFB |
Data areas and their retentivity |
Flag |
● Number, max. |
256 byte |
● Retentivity available |
Yes; MB 0 to MB 255 |
Address area |
I/O address area |
● Inputs |
1 kbyte |
● Outputs |
1 kbyte |
Process image |
● Inputs |
128 byte |
● Outputs |
128 byte |
Digital channels |
● Inputs |
992 |
● Outputs |
992 |
Analog channels |
● Inputs |
248 |
● Outputs |
124 |
Hardware configuration |
Number of DP masters |
● Via CP |
1 |
Number of operable FMs and CPs (recommended) |
● FM |
4 |
● CP, point-to-point |
4 |
● CP, LAN |
4 |
Expansion modules |
● Number of expansion modules, max. |
4; max. 2 flat structure, max. 4 deep structure |
Rack |
● Racks, max. |
1 |
● Modules per rack, max. |
4 |
Time of day |
Clock |
● Hardware clock (real-time clock) |
Yes |
● battery-backed and synchronizable |
Yes |
Operating hours counter |
● Number |
1 |
Clock synchronization |
● supported |
Yes |
Digital inputs |
Number of digital inputs |
24 |
Input voltage |
● Rated value, DC |
24 V |
● for signal "0" |
-3 to +5V |
● for signal "1" |
15 to 30 V |
Input current |
● for signal "1", typ. |
8 mA |
Input delay (for rated value of input voltage) |
for standard inputs |
— Parameterizable |
Yes; 0.1 / 0.3 / 3 / 15 ms |
for counter/technological functions |
— at "0" to "1", max. |
16 µs |
Cable length |
● Cable length, shielded, max. |
1 000 m; 100 m for technological functions |
● Cable length unshielded, max. |
600 m |
Digital outputs |
Number of digital outputs |
16 |
short-circuit protection |
Yes; Clocked electronically |
Limitation of inductive shutdown voltage to |
L+ (-48 V) |
Output voltage |
● for signal "1", min. |
L+ (-0.8 V) |
Output current |
● for signal "1" permissible range for 0 to 40 °C, max. |
0.5 A |
● for signal "1" permissible range for 40 to 60 °C, max. |
0.5 A |
● for signal "1" minimum load current |
5 mA |
● for signal "0" residual current, max. |
0.5 mA |
Switching frequency |
● with resistive load, max. |
100 Hz |
● with inductive load, max. |
0.5 Hz |
Aggregate current of outputs (per group) |
all mounting positions |
— up to 40 °C, max. |
4 000 mA |
— up to 60 °C, max. |
2 000 mA |
Cable length |
● Cable length, shielded, max. |
1 000 m |
● Cable length unshielded, max. |
600 m |
Analog inputs |
Number of analog inputs |
4 |
Number of analog inputs for voltage/current measurement |
4 |
Number of analog inputs for resistance/resistance thermometer measurement |
1 |
Input ranges |
● Voltage |
Yes |
● Current |
Yes |
● Resistance thermometer |
Yes |
● Resistance |
Yes |
Input ranges (rated values), voltages |
● 0 to +10 V |
Yes |
● -10 V to +10 V |
Yes |
Input ranges (rated values), currents |
● 0 to 20 mA |
Yes |
● -20 to +20 mA |
Yes |
● 4 to 20 mA |
Yes |
Input ranges (rated values), resistance thermometer |
● Pt 100 |
Yes |
Input ranges (rated values), resistors |
● 0 to 600 ohms |
Yes |
Analog outputs |
Number of analog outputs |
2 |
Output ranges, voltage |
● 0 to 10 V |
Yes |
● -10 to +10 V |
Yes |
Output ranges, current |
● 0 to 20 mA |
Yes |
● -20 to +20 mA |
Yes |
● 4 to 20 mA |
Yes |
Analog value creation |
Integration and conversion time/resolution per channel |
● Resolution with overrange (bit including sign), max. |
12 bit |
● Integration time, parameterizable |
Yes; 2,5 / 16,6 / 20 ms |
● Conversion time (per channel) |
1 ms |
Encoder |
Connectable encoders |
● 2-wire sensor |
Yes |
— Permissible quiescent current (2-wire sensor), max. |
1.5 mA |
Errors/accuracies |
Basic error limit (operational limit at 25 °C) |
● Voltage, relative to input area, (+/-) |
0.7 % |
● Current, relative to input area, (+/-) |
0.7 % |
● Resistance, relative to input area, (+/-) |
3 % |
● Resistance thermometer, relative to input area, (+/-) |
3 % |
● Voltage, relative to output area, (+/-) |
0.7 % |
● Current, relative to output area, (+/-) |
0.7 % |
Interfaces |
MPI |
● Cable length, max. |
50 m; without repeater |
1st interface |
Isolated |
No |
Functionality |
● MPI |
Yes |
● DP master |
No |
● DP slave |
No |
MPI |
● Number of connections |
8 |
● Transmission rate, max. |
187.5 kbit/s |
Services |
— PG/OP communication |
Yes |
— Global data communication |
Yes |
— S7 basic communication |
Yes |
— S7 communication |
Yes |
— S7 communication, as client |
No |
— S7 communication, as server |
Yes |
Communication functions |
PG/OP communication |
Yes |
Global data communication |
● Number of GD packets, transmitter, max. |
4 |
● Number of GD packets, receiver, max. |
4 |
● Size of GD packets, max. |
22 byte |
S7 basic communication |
● supported |
Yes |
● User data per job, max. |
76 byte |
S7 communication |
● supported |
Yes |
● User data per job, max. |
64 kbyte |
Number of connections |
● overall |
8 |
● usable for PG communication |
|
— reserved for PG communication |
1 |
— Adjustable for PG communication, max. |
7 |
● usable for OP communication |
|
— reserved for OP communication |
1 |
— adjustable for OP communication, max. |
7 |
● usable for S7 basic communication |
|
— Reserved for S7 basic communication |
4 |
— adjustable for S7 basic communication, max. |
4 |
● Number of logical connections (also in network), max. |
1; fixed with integrated CPU |
S7 message functions |
Number of login stations for message functions, max. |
5 |
Integrated Functions |
Number of counters |
3 |
Counter frequency (counter) max. |
30 kHz |
Frequency measurement |
Yes |
PID controller |
Yes |
Number of pulse outputs |
3 |
Limit frequency (pulse) |
2.5 kHz |
Galvanic isolation |
Galvanic isolation digital inputs |
● between the channels |
Yes |
● between the channels, in groups of |
8; 16 and 8 |
Galvanic isolation digital outputs |
● between the channels |
Yes |
● between the channels, in groups of |
8 |
Galvanic isolation analog inputs |
● Galvanic isolation analog inputs |
Yes; common for analog I/O |
Galvanic isolation analog outputs |
● Galvanic isolation analog outputs |
Yes; common for analog I/O |
Isolation |
tested with |
● 24 V DC circuits |
500 V; DC |
EMC |
Emission of radio interference acc. to EN 55 011 |
● Emission of radio interference |
Interference emission to EN 50081-2, testing to EN 55011, Class A, Group 1 |
● Limit class A, for use in industrial areas |
Yes; Group 1 |
Degree and class of protection |
Degree of protection to EN 60529 |
|
● IP20 |
Yes; Housing |
● IP65 |
Yes; Front |
Ambient conditions |
Environmental conditions |
Not suitable for open-air use |
Operating temperature |
● 45 degree installation, min. |
0 °C |
● 45 degree installation, max. |
45 °C |
● horizontal installation, min. |
0 °C |
● horizontal installation, max. |
40 °C |
● vertical installation, min. |
0 °C |
● vertical installation, max. |
50 °C |
Air pressure |
● permissible range, min. |
795 hPa |
● permissible range, max. |
1 080 hPa |
Relative humidity |
● Operation, min. |
5 % |
● Operation, max. |
95 %; RH class 2 in accordance with IEC 1131-2 |
Vibrations |
● Operation, checked according to IEC 60068-2-6 |
Yes; 10 to 58 Hz: Constant amplitude 0.075 mm; 58 to 500 Hz: Constant acceleration 1 g |
● Transport tested checked to IEC 60068-2-6 |
Yes; 5 to 9 Hz: amplitude 3.5 mm; 9 to 500 Hz: acceleration 1 g |
Shock test |
● checked according to IEC 60068-2-29 |
Yes; in operation: Half-sine: Strength of the shock 15 g (peak value), duration 11 ms, 18 shocks; in storage: 25 g, 6 ms, 1000 shocks |
Configuration |
Configuration software |
● STEP 7 |
Yes; V5.1 SP3, STEP 7 Lite |
programming |
● Nesting levels |
8 |
Programming language |
— LAD |
Yes |
— FBD |
Yes |
— STL |
Yes |
— SCL |
Yes |
— CFC |
Yes |
— GRAPH |
Yes |
— HiGraph® |
Yes |
Know-how protection |
● User program protection/password protection |
Yes |
Languages |
Online languages |
● Number of online/runtime languages |
3 |
Mechanics/material |
Lifetime, typ. |
● Number of operating cycles, keys |
1 000 000 |
Dimensions |
Width |
215 mm |
Height |
165 mm |
Depth |
79 mm |
Mounting cutout/device depth (W x H x T) |
|
● Mounting cutout, width |
202 mm |
● Mounting cutout, height |
152 mm |
Weights |
Weight, approx. |
1 350 g |
last modified: |
25.09.2014 |