6ES7132-1BL00-0XB0 ET200L, EL-BLOCK, 32DO, DC 24V, 0.5A

Product Code: 6ES7132-1BL00-0XB0

Availability: In Stock

Price: $176.05
  
 
Artikelnummer 6ES7132-1BL00-0XB0
General information
Vendor identification (VendorID) 0011h
Supply voltage
24 V DC Yes
Reverse polarity protection Yes
Mains buffering
● Mains buffering, min. 20 ms
Load voltage 2L+
● Rated value (DC) 24 V; 1L+, 2L+, 3L+
Input current
from load voltage L1 (without load), max. 100 mA; Per load group (L1+ or L2+ / L3+)
from supply voltage L+, max. 70 mA; L4+ / L5+
Power loss
Power loss, typ. 7 W
Hardware configuration
Rack
● required terminal block TB 32L
Digital outputs
Number of digital outputs 32
Short-circuit protection Yes
● Response threshold, typ. 0,7 A
Limitation of inductive shutdown voltage to Typ. (L1+ or L2+ / L3+) -55 V
Controlling a digital input Yes
Switching capacity of the outputs
● Lamp load, max. 5 W
Load resistance range
● lower limit 41 Ω
● upper limit 28 000 Ω
Output voltage
● Rated value (DC) 24 V
● for signal "1", min. Ua - 3 V
Output current
● for signal "1" rated value 0.5 A
● for signal "1" permissible range for 0 to 60 °C, max. 0.5 A
● for signal "0" residual current, max. 1 mA
Output delay with resistive load
● "0" to "1", max. 50 ms
● "1" to "0", max. 200 ms
Parallel switching of 2 outputs
● for uprating No
● for redundant control of a load Yes; only outputs of the same group
Switching frequency
● with resistive load, max. 100 Hz
● with inductive load, max. 0.5 Hz
● on lamp load, max. 8 Hz
Total current of the outputs (per group)
all mounting positions
— up to 60 °C, max. 4 A
horizontal installation
— up to 40 °C, max. 3 000 mA
— up to 60 °C, max. 2 000 mA
all other mounting positions
— up to 40 °C, max. 2 A
Cable length
● Cable length, shielded, max. 1 000 m
● Cable length unshielded, max. 600 m
Interfaces
PROFIBUS DP
● Transmission rate, max. 1.5 Mbit/s
● SYNC capability Yes
● Direct data exchange (slave-to-slave communication) Yes; Transmitter (for digital outputs and hybrid modules ET 200L: not for L-SC or IM-SC)
Communication functions
Bus protocol/transmission protocol PROFIBUS DP
Interrupts/diagnostics/status information
Alarms
● Alarms No
Diagnostic messages
● Diagnostic functions Yes
Diagnostics indication LED
● Bus fault BF (red) Yes
● Status indicator digital output (green) Yes
● Status indicator digital input (green) Yes
● Monitoring 24 V voltage supply ON (green) Yes
Galvanic isolation
between PROFIBUS DP and all other circuit components Yes
Galvanic isolation digital outputs
● between the channels No
● between the channels and PROFIBUS DP Yes
Isolation
Isolation tested with 500 V DC
Degree and class of protection
IP20 Yes
Ambient conditions
Operating temperature
● horizontal installation, min. 0 °C
● horizontal installation, max. 60 °C; 40°C for other mountings
Air pressure
● permissible range, min. 795 hPa
● permissible range, max. 1 080 hPa
Relative humidity
● Operation, min. 5 %
● Operation, max. 95 %; RH class 2 in accordance with IEC 1131-2
Vibrations
● Operation, tested according to IEC 60068-2-6 Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g)
Shock test
● tested according to IEC 60068-2-27 Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms
Connection method
Inputs/outputs Screw-type and spring-loaded terminals, permanent wiring; standard: 2-wire connection, optional: 3 and 4-wire connection
Dimensions
Width 145 mm
Height 60 mm
Depth 60.5 mm
Weights
Weight, approx. 150 g
last modified: 21.08.2014