6GK7542-1AX00-0XE0 COMMUNICATION MODULE CM 1542-1

Product Code: 6GK7542-1AX00-0XE0

Availability: In Stock

Price: $100,000,000,000.00
Artikelnummer 6GK7542-1AX00-0XE0
Product type designation CM 1542-1
COMMUNICATIONS MODULE CM 1542-1 FOR CONNECTING S7-1500 TO PROFINET AS IO-CONTROLLER: TCP/IP, ISO-ON-TCP, UDP, S7-COMMUNICATION, IP-BROADCAST/ MULTICAST, SNMPV1, DHCP, CLOCK SYNCHRONISATION VIA NTP, 2XRJ45 (10/100 MBIT)
Transmission rate
Transfer rate
● at the 1st interface 10 ... 100 Mbit/s
Interfaces
Number of interfaces / acc. to Industrial Ethernet 0
Number of electrical connections
● at the 1st interface / acc. to Industrial Ethernet 2
Design of the electrical connection
● at the 1st interface / acc. to Industrial Ethernet RJ45 port
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltage DC
Supply voltage / 1 / from backplane bus 15 V
Relative symmetrical tolerance / for DC
● at 15 V 3 %
Consumed current
● from backplane bus / for DC / at 15 V / typical 0.22 A
Active power loss 3.3 W
Permitted ambient conditions
Ambient temperature
● for vertical installation / during operation 0 ... 40 °C
● for horizontally arranged busbars / during operation 0 ... 60 °C
● during storage -40 ... +70 °C
● during transport -40 ... +70 °C
Relative humidity / at 25 °C / without condensation / during operation / maximum 95 %
Protection class IP IP20
Design, dimensions and weight
Module format Compact module S7-1500 single width
Width 35 mm
Height 142 mm
Depth 129 mm
Net weight 0.4 kg
Mounting type
● S7-1500 rail mounting Yes
Product properties, functions, components / general
Number of units
● per CPU / maximum 8
● Note depending on CPU type
Performance data
Performance data / open communication
Number of possible connections / for open communication / by means of T blocks / maximum 64; depending on the system upper limit
Amount of data / as user data per ISO on TCP connection / for open communication / by means of T blocks / maximum 65536 byte
Number of Multicast stations 6
Performance data / S7 communication
Number of possible connections / for S7 communication
● maximum 64
● Note depending on the system upper limit
Performance data / multi-protocol mode
Number of active connections / with multi-protocol mode 64
Performance data / PROFINET communication / as PN IO-Controller
Product function / PROFINET IO controller Yes
Number of PN IO devices / on PROFINET IO controller / usable / total 128
Number of PN IO IRT devices / on PROFINET IO controller / usable 64
Number of external PN IO lines / with PROFINET / per rack 10
Amount of data
● as user data for input variables / as PROFINET IO controller / maximum 8 Kibyte
● as user data for input variables / as PROFINET IO controller / maximum 8 Kibyte
● as user data for input variables per PN IO device / as PROFINET IO controller / maximum 1433 byte
● as user data for output variables per PN IO device / as PROFINET IO controller / maximum 1433 byte
● as user data for input variables per PN IO device / for each sub-module as PROFINET IO controller / maximum 256 byte
● as user data for output variables per PN IO device / for each sub-module as PROFINET IO controller / maximum 256 byte
Performance data / telecontrol
Protocol / is supported
● TCP/IP Yes
Product functions / management, configuration
Product function / MIB support Yes
Protocol / is supported
● SNMP v1 Yes
● DCP Yes
● LLDP Yes
Configuration software
● required STEP 7 Professional V13 (TIA Portal) or higher
Identification & maintenance function
● I&M0 - device-specific information Yes
● I&M1 – higher-level designation/location designation Yes
Product functions / Diagnosis
Product function / Web-based diagnostics Yes; yes, via S7-1500 CPU
Product functions / switch
Product feature / Switch Yes
Product function
● switch-managed No
● with IRT / PROFINET IO switch Yes
● Configuration with STEP 7 Yes
Product functions / Redundancy
Product function
● Ring redundancy Yes
● Redundancy manager Yes
● Media Redundancy Protocol (MRP) Yes
Product functions / Security
Product function
● switch-off of non-required services Yes
● Blocking of communication via physical ports No
● log file for unauthorized access No
Product functions / Time
Product function / SICLOCK support Yes
Product function / pass on time synchronization Yes
Protocol / is supported / NTP Yes
Further Information / Internet Links
Internet-Link
● to website: Selector SIMATIC NET SELECTION TOOL http://www.siemens.com/snst
● to website: Industrial communication http://www.siemens.com/simatic-net
● to website: Information and Download Center http://www.siemens.com/automation/net/catalog
● to website: Image database http://automation.siemens.com/bilddb
● to website: CAx Download Manager http://www.siemens.com/cax
● to website: Industry Online Support http://support.automation.siemens.com
last modified: 03.11.2014
Date
04.11.2014
Changes preserved
© Copyright Siemens AG 2014

Write a review

Note: HTML is not translated!

Rating: Bad Good

Enter the code in the box below: