6GK7443-1EX30-0XE0 COMMUNICATION PROCESSOR CP 443-1

Product Code: 6GK7443-1EX30-0XE0

Availability: In Stock

Price: $100,000,000,000.00
Artikelnummer 6GK7443-1EX30-0XE0
Product type designation CP 443-1
SIMATIC NET CP 443-1 2 X 10/100 MBIT/S (IE SWITCH); RJ 45 PORTS; ISO; TCP; UDP; PROFINET-IO CONTROLLER; S7-COMMUNCATION; OPEN COMMUNICATION (SEND/RE- CEIVE); S7-ROUTING; IP-CONFIGU- RATION VIA DHCP/BLOCK; IP ACCESSS CONTROL LIST; TIME- SYNCHRONISATION; EXTENDED WEB-DIAGNOSIS; FAST STARTUP; PROFIENERGY SUPPORT
Transmission rate
Transfer rate
● at the 1st interface 10 ... 100 Mbit/s
Interfaces
Number of interfaces / acc. to Industrial Ethernet 2
Number of electrical connections
● at the 1st interface / acc. to Industrial Ethernet 2
Design of the electrical connection
● at the 1st interface / acc. to Industrial Ethernet RJ45 port
design of the removable storage / C-PLUG No
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltage DC
Supply voltage / 1 / from backplane bus 5 V
Relative symmetrical tolerance / for DC
● at 5 V 5 %
Consumed current
● from backplane bus / for DC / at 5 V / typical 1.4 A
Active power loss 8.6 W
Permitted ambient conditions
Ambient temperature
● during operation 0 ... 60 °C
● during storage -40 ... +70 °C
● during transport -40 ... +70 °C
Relative humidity / at 25 °C / without condensation / during operation / maximum 95 %
Protection class IP IP20
Design, dimensions and weight
Module format Compact module S7-400 single width
Width 25 mm
Height 290 mm
Depth 210 mm
Net weight 0.7 kg
Product properties, functions, components / general
Number of units
● per CPU / maximum 14
● Note max. 4 as PN IO ctrl.
Performance data
Performance data / open communication
Number of possible connections / for open communication / by means of SEND/RECEIVE blocks
● maximum 64
Amount of data
● as user data per ISO connection / for open communication / by means of SEND/RECEIVE blocks / maximum 8 Kibyte
● as user data per ISO on TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum 8 Kibyte
● as user data per TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum 8 Kibyte
● as user data per UDP connection / for open IE communication / by means of SEND/RECEIVE blocks / maximum 2 Kibyte
Number of possible connections / for open communication / by means of T blocks / maximum 64
Amount of data / as user data per ISO on TCP connection / for open communication / by means of T blocks / maximum 1452 byte
Performance data / S7 communication
Number of possible connections / for S7 communication
● maximum 128
● with PG connections / maximum 2
● Note when using several CPUs
Performance data / multi-protocol mode
Number of active connections / with multi-protocol mode 128
Performance data / PROFINET communication / as PN IO-Controller
Product function / PROFINET IO controller Yes
Number of PN IO devices / on PROFINET IO controller / usable / total 128
Number of PN IO IRT devices / on PROFINET IO controller / usable 64
Number of external PN IO lines / with PROFINET / per rack 4
Amount of data
● as user data for input variables / as PROFINET IO controller / maximum 4 Kibyte
● as user data for input variables / as PROFINET IO controller / maximum 4 Kibyte
● as user data for input variables per PN IO device / as PROFINET IO controller / maximum 1433 byte
● as user data for output variables per PN IO device / as PROFINET IO controller / maximum 1433 byte
● as user data for input variables per PN IO device / for each sub-module as PROFINET IO controller / maximum 240 byte
● as user data for output variables per PN IO device / for each sub-module as PROFINET IO controller / maximum 240 byte
Performance data / telecontrol
Protocol / is supported
● TCP/IP Yes
Product functions / management, configuration
Product function / MIB support Yes
Protocol / is supported
● SNMP v1 Yes
● DCP Yes
● LLDP Yes
Configuration software
● required STEP 7 V5.5 SP3 or higher / STEP 7 Professional V12 (TIA Portal) or higher
Product functions / Diagnosis
Product function / Web-based diagnostics Yes
Product functions / switch
Product feature / Switch Yes
Product function
● switch-managed No
● with IRT / PROFINET IO switch Yes
● Configuration with STEP 7 Yes
Product functions / Redundancy
Product function
● Ring redundancy Yes
● Redundancy manager Yes
● Media Redundancy Protocol (MRP) Yes
Product functions / Security
Product function
● password protection for Web applications No
● ACL - IP-based Yes
● ACL - IP-based for PLC/routing No
● switch-off of non-required services Yes
● Blocking of communication via physical ports Yes
● log file for unauthorized access No
Product functions / Time
Product function / SICLOCK support Yes
Product function / pass on time synchronization Yes
Protocol / is supported / NTP Yes
Further Information / Internet Links
Internet-Link
● to website: Selector SIMATIC NET SELECTION TOOL http://www.siemens.com/snst
● to website: Industrial communication http://www.siemens.com/simatic-net
● to website: Information and Download Center http://www.siemens.com/automation/net/catalog
● to website: Image database http://automation.siemens.com/bilddb
● to website: CAx Download Manager http://www.siemens.com/cax
● to website: Industry Online Support http://support.automation.siemens.com
last modified: 03.11.2014
Date
03.11.2014
Changes preserved
© Copyright Siemens AG 2014

Write a review

Note: HTML is not translated!

Rating: Bad Good

Enter the code in the box below: