Product type designation |
RUGGEDCOM MX5000 |
Product description |
|
|
THE RUGGEDCOM MX5000 IS AN MIL-STD HIGH PORT DENSITY ROUTING AND SWITCHING PLATFORM, DESIGNED TO OPERATE IN THE MOST DEMANDING ENVIRONMENTS. THE RUGGEDCOM MX5000 CAN WITHSTAND HIGH LEVELS OF ELECTROMAGNETIC INTERFERENCE, RADIO FREQUENCY INTERFERENCE AND A WIDE TEMPERATURE RANGE OF -40 CEL TO +85 CEL. UP TO 48 10/100TX MICROD UP TO 96 10/100TX RJ45 PORTS UP TO 48 100FX OPTICAL PORTS UP TO 2 GIGABIT ETHERNET PORTS LONG-HAUL OPTICS ALLOW DISTANCES UP TO 90KM MULTIPLE CONNECTOR TYPES (ST AND LC) |
Transmission rate |
Transfer rate |
10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, 10 Gbit/s |
Interfaces |
Number of electrical/optical connections |
|
● for network components or terminal equipment / maximum |
98 |
● for network components or terminal equipment / maximum / Note |
up to 96 x 10/100TX RJ45 Ports + 2 Ports via Switch Modul |
● for gigabit Ethernet / maximum |
26 |
Number of electrical connections |
|
● for network components or terminal equipment / maximum |
96 |
● for gigabit Ethernet / maximum |
24 |
● for serial interfaces / acc. to RS 232/RS 422/RS 485 / maximum |
48 |
● for operator console |
1 |
● for management purposes |
1 |
Design of the electrical connection |
|
● for operator console |
RS232 |
● for management purposes |
RJ45 |
● for power supply |
3-pole terminal block, permanently installed |
Number of optical interfaces |
|
● for network components or terminal equipment / maximum |
48 |
Range / at the optical interface / depending on the optical fiber used |
2 ... 90 km |
● with gigabit |
0.5 ... 25 km |
Signal-Inputs/outputs |
Relay design |
Form-C contact relay (SP CO) |
Type of relay output |
Changeover contact |
Operating voltage / of the signaling contacts |
|
● with AC / maximum |
150 V |
● for DC / maximum |
125 V |
Operating current / of the signaling contacts |
|
● with AC / at 250 V / maximum |
2 A |
● for DC / at 30 V / maximum |
2 A |
Supply voltage, current consumption, power loss |
product options / wide range power supply |
Yes |
Product property |
|
● Modular power supply |
Yes |
● Hot-swappable power supply |
Yes |
Supply voltage / 3 / Rated value |
|
● Supply voltage / 3 / Rated value |
88 ... 300 V |
● Type of voltage / 3 / of the supply voltage |
DC |
Supply voltage / 4 / Rated value |
|
● Supply voltage / 4 / Rated value / minimum |
85 V |
● Supply voltage / 4 / Rated value / maximum |
264 V |
● Type of voltage / 4 / of the supply voltage |
AC |
Permitted ambient conditions |
Ambient temperature |
|
● during operation |
-40 ... +85 °C |
● Note |
A maximum operating temperature of +85 °C is permissible for a duration of 16 hours |
Operating condition / fanless operation |
Yes |
Coating |
Conformal Coating optional |
Protection class IP |
IP40 |
Design, dimensions and weight |
Design |
19" rack |
Number of slots |
6 |
Width |
454.66 mm |
Height |
175.26 mm |
Depth |
302.006 mm |
Net weight |
Weight is depending on the built in modules |
Material / of the enclosure |
18 AWG galvanized steel enclosure |
Mounting type |
|
● 19-inch installation |
Yes |
● 35 mm DIN rail mounting |
No |
● wall mounting |
Yes |
Product properties, functions, components / general |
Product function |
|
● RAW socket mode for any serial protocols |
Yes |
Number of automatically learnable MAC addresses |
98304 |
Storage capacity |
|
● of the MAC-address table |
64 Kibyte |
Switch latency period |
10.5 µs |
Transfer rate / of the switch |
88 Gbit/s |
Number of priority channels |
4 |
Product property |
|
● no head-off-line-blocking |
Yes |
● Store & Forward switching method |
Yes |
● Zero-Packet-Loss technology |
Yes |
Product functions / management, configuration |
Product function |
|
● CLI |
Yes |
● web-based management |
Yes |
● MIB support |
Yes |
● RMON |
Yes |
● switch-managed |
Yes |
Protocol / is supported |
|
● Telnet |
Yes |
● HTTP |
Yes |
● HTTPS |
No |
● TFTP |
Yes |
● NETCONF |
Yes |
● IGMP (snooping/querier) |
Yes |
Number of groups / at IGMP |
256 |
Protocol / is supported |
|
● SNMP v1 |
Yes |
● SNMP v2 |
No |
● SNMP v2c |
Yes |
● SNMP v3 |
Yes |
Product function / for MIB support |
|
● by BRIDGE-MIB |
RFC1493 |
● by IF-MIB |
RFC2863 |
● by RMON-MIB |
RFC2819 |
● by RSTP-MIB |
draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB |
● by SNMPv2-MIB |
RFC1907 |
● by SNMPv2-SMI |
RFC2578 |
● by SNMPv2-TC |
RFC2579 |
● by TCP-MIB |
RFC2012 |
● by UDP-MIB |
RFC2013 |
Product functions / VLAN |
Product function |
|
● VLAN - port based |
Yes |
Number of VLANs / maximum |
255 |
VLAN identification number |
1 ... 4094 |
Protocol / is supported / GVRP |
Yes |
Product functions / DHCP |
Product function |
|
● DHCP client |
Yes |
● DHCP Option 82 |
No |
● DHCP Option 66 |
No |
● DHCP Option 67 |
No |
Product functions / Routing |
Product function |
|
● dynamic IP routing |
Yes |
Protocol / is supported |
|
● RIP v1 |
Yes |
● RIPv2 |
Yes |
● OSPFv2 |
Yes |
● VRRP |
No |
● BGP |
Yes |
Product functions / Redundancy |
Product function |
|
● redundancy procedure STP |
Yes |
● redundancy procedure RSTP |
Yes |
● redundancy procedure MSTP |
Yes |
● eRSTP |
Yes |
Protocol / is supported |
|
● STP |
Yes |
● RSTP |
Yes |
● MSTP |
Yes |
Product functions / Security |
Product function |
|
● ACL - MAC-based |
Yes |
● ACL-Role based |
Yes |
● IEEE 802.1x (radius) |
Yes |
● Blocking of communication via physical ports |
Yes |
Protocol / is supported |
|
● SSH |
Yes |
Product function / port-rate-limiting |
Yes |
Product functions / Time |
Protocol / is supported |
|
● SNTP |
Yes |
Type of time synchronization |
NTP |
Standards, specifications, approvals |
Standard |
|
● for EMC |
FCC Part 15 (Class A), EN55022 (CISPR22 Class A) |
● for safety / from CSA and UL |
cTUVus (Compliant to UL 60950-1:2007, CAN/CSA-C22.2 No. 60950-1-07, EN 60950-1:2006) |
Laser protection class |
Complies with 21 CFR Chapter1, Subchapter J |
Certificate of suitability |
|
● CE marking |
Yes |
● IEC 61850-3 |
Yes |
product conformity |
|
● acc. to IEEE 802.3-10BaseT |
Yes |
● acc. to IEEE 802.3u-100BaseTX |
Yes |
● acc. to IEEE 802.3u-100BaseFX |
Yes |
● acc. to IEEE 802.3ab-1000BaseT |
Yes |
● acc. to IEEE 802.3z-1000BaseLX |
Yes |
● acc. to IEEE 802.3ad-Link Aggregation |
Yes |
● acc. to IEEE 802.3x-Flow Control |
Yes |
● acc. to IEEE 802.1d-MAC Bridges |
Yes |
● acc. to IEEE 802.1d-STP |
Yes |
● acc. to IEEE 802.1p-class of service |
Yes |
● acc. to IEEE 802.1Q-VLAN tagging |
Yes |
● acc. to IEEE 802.1Q-2005 (formerly IEEE 802.1s) MSTP |
Yes |
● acc. to IEEE 802.1w-RRST |
Yes |
● acc. to MIL-STD 167-Vibration |
Yes |
● acc. to MIL-STD 461-EMI |
Yes |
● acc. to MIL-STD 810-Temperature and Humidity |
Yes |
● acc. to MIL-S 901D-Shock (Hard Mounted) |
Yes |
● acc. to MIL-STD 1399 Magnetic Field (DC Magnetic Exposure) |
Yes |
● RFC768-UDP |
Yes |
● RFC783-TFTP |
Yes |
● RFC791-IP |
Yes |
● RFC792-ICMP |
Yes |
● RFC793-TCP |
Yes |
● RFC826-ARP |
Yes |
● RFC854-Telnet |
Yes |
● RFC894-IP over Ethernet |
Yes |
● RFC1112-IGMPv1 |
Yes |
● RFC1519-CIDR |
Yes |
● RFC1541-DHCP (client) |
Yes |
● RFC2030-SNTP |
Yes |
● RFC2068-HTTP |
Yes |
● RFC2236-IGMPv2 |
Yes |
● RFC2475-Differentiated Service |
Yes |
Further Information / Internet Links |
Internet-Link |
|
● to website: Industry Mall/RUGGEDCOM selector |
http://ruggedcom-selector.automation.siemens.com |
● to website: Siemens RUGGEDCOM |
http://siemens.com/ruggedcom |
● to website: Selector for cables and connectors |
http://www.siemens.com/snst |
● to website: Industrial communication |
http://www.siemens.com/simatic-net |
● to website: Information and Download Center |
http://www.siemens.com/automation/net/catalog |
● to website: Image database |
http://automation.siemens.com/bilddb |
● to website: CAx Download Manager |
http://www.siemens.com/cax |
● to website: Industry Online Support |
http://support.automation.siemens.com |
Security information |
Security information |
Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4) |
last modified: |
23.10.2014 |
Date 30.10.2014 |
Changes preserved © Copyright Siemens AG 2014 |