Product type designation |
SCALANCE WLC711 (NAM) |
Product description |
Supports Access Points SCALANCE W786C, W788C |
|
IWLAN CONTROLLER SCALANCE WLC711; NATIONAL APPROVALS FOR USE IN NORTHERN AMERICA INCL.CANADA (NAM); FOR 16 ACCESS POINTS; EXPANDABLE TO 48 ACCESS POINTS; REDUNDACY; LAYER 3-ROAMING; VOIP SUPPORT; POWER DISTRIBUTION; INTERNAL CAPTIVE PORTAL PLEASE NOTE NATIONAL APPROVALS! |
Suitability for use |
Basic license for 16 Access Points preinstalled, can be estended with up to 2 Capacity Upgrade License Key WLC-700 |
Transmission rate |
Transfer rate |
|
● for Industrial Ethernet |
10 Mbit/s, 1000 Mbit/s |
Interfaces |
Number of electrical connections |
|
● for network components or terminal equipment |
2 |
● for power supply |
1 |
Design of the electrical connection |
|
● for network components or terminal equipment |
RJ45 socket |
● for power supply |
2-pole screw terminal |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage |
DC |
Supply voltage / 1 |
|
● from terminal block |
24 V |
Consumed current |
|
● for DC / at 24 V / typical |
4 A |
Active power loss |
|
● for DC / at 24 V / typical |
20 W |
Permitted ambient conditions |
Ambient temperature |
|
● during operation |
5 ... 40 °C |
● during storage |
-40 ... +60 °C |
● during transport |
-40 ... +60 °C |
Relative humidity / at 25 °C / without condensation / during operation / maximum |
95 % |
Protection class IP |
IP20 |
Design, dimensions and weight |
Width |
262 mm |
Height |
142 mm |
Depth |
47 mm |
Net weight |
2 kg |
Mounting type |
Wall mounting using the supplied mounting brackets |
● wall mounting |
Yes |
Product functions / management, configuration |
Product function |
|
● CLI |
Yes |
● web-based management |
Yes |
● MIB support |
Yes |
● WDS |
Yes |
Protocol / is supported |
|
● Address Resolution Protocol (ARP) |
No |
● ICMP |
Yes |
● Telnet |
Yes |
● HTTP |
Yes |
● HTTPS |
Yes |
● TFTP |
Yes |
● DCP |
No |
● LLDP |
No |
Product functions / Diagnosis |
Product function |
|
● SysLog |
Yes |
Protocol / is supported |
|
● SNMP v2 |
Yes |
● SNMP v3 |
Yes |
Product functions / VLAN |
Product function |
|
● function VLAN with IWLAN |
Yes |
Product functions / DHCP |
Product function |
|
● DHCP client |
No |
Product functions / Security |
Product function |
|
● IEEE 802.1x (radius) |
Yes |
● NAT/NAPT |
No |
● access protection according to IEEE802.11i |
Yes |
● WPA/WPA2 |
Yes |
● TKIP/AES |
Yes |
Protocol / is supported |
|
● SSH |
Yes |
Product functions / Time |
Protocol / is supported |
|
● NTP |
Yes |
● SNTP |
No |
● SIMATIC Time |
No |
Product functions / IWLAN controller |
Number of supported access points |
|
● in standard mode with one IWLAN controller |
48 |
● in redundancy mode with two IWLAN controllers |
96 |
Number of supported WLAN clients / per IWLAN controller |
512 |
Number of VNS segments / per IWLAN controller |
8 |
Product function |
|
● of the IWLAN controller |
If delivered with basic license, 16 access points can operated in standard mode and 32 access points can operate in redundant mode. A capacity upgrade permits 48 access points in standard mode and 96 access points in redundant mode. |
● Pre-standard (CAPWAP) |
Yes |
● integrated VLAN-VNS |
Yes |
● auto-detection of new access points |
Yes |
● CDR/RADIUS accounting |
Yes |
● Dynamic Radio Management |
Yes |
Load distribution function |
DRM (Dynamic Radio/ RF Management), Packet Fairness, Flexible Client Access (Airtime Fairness), Load Balancing, Band-Steering |
Product function |
|
● VoIP QoS mapping (DSCP/TCP-on-WMM) |
Yes |
● VoIP roaming between IP subnets |
Yes |
● VoIP roaming between several IWLAN controllers |
Yes |
Backup function for IWLAN controller |
Redundancy mode with two IWLAN controllers (with full capacity upgrade for both controllers, both controllers can be operated with 48 access points each. If one controller fails, the remaining controller can handle 96 access points.) |
Switching function |
Traffic bridged at controller/traffic bridged locally at wireless access point |
Design of the interface / for public network access |
Internal captive portal (web redirection) |
Standards, specifications, approvals |
Standard |
|
● for FM |
- |
● for safety / from CSA and UL |
UL 60950-1 CSA C22.2 No. 60950-1, UL 508 CAN/CSA C22.2 No. 142 |
Certificate of suitability |
|
● EC declaration of conformity |
Yes |
● CE marking |
Yes |
● C-Tick |
Yes |
● E1 approval |
No |
● Railway application in accordance with EN 50155 |
No |
● NEMA4X |
No |
● Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af |
No |
● Power-over-Ethernet according to IEEE802.3at for type 2 |
No |
Standard for wireless communication |
|
● IEEE 802.11a |
Yes |
● IEEE 802.11b |
Yes |
● IEEE 802.11e |
Yes |
● IEEE 802.11g |
Yes |
● IEEE 802.11h |
Yes |
● IEEE 802.11i |
Yes |
● IEEE 802.11n |
Yes |
Wireless approval |
You can find the current list of countries at: www.siemens.com/simatic-net/ik-info |
Accessories |
accessories |
24 V DC screw terminal and 2 mounting brackets included in the scope of delivery |
Further Information / Internet Links |
Internet-Link |
|
● to website: TIA Selection Tool |
http://www.siemens.com/tia-selection-tool |
● to the website: IWLAN |
http://www.siemens.com/iwlan |
● to website: Industry Mall |
https://mall.industry.siemens.com |
● to website: Information and Download Center |
http://www.siemens.com/automation/net/catalog |
● to website: Image database |
http://automation.siemens.com/bilddb |
● to website: CAx Download Manager |
http://www.siemens.com/cax |
● to website: Industry Online Support |
http://support.automation.siemens.com |
Security information |
Security information |
Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4) |
last modified: |
01.12.2014 |
Date 11.12.2014 |
Changes preserved © Copyright Siemens AG 2014 |