Product type designation |
SCALANCE XR324-4M POE |
Product description |
|
|
SCALANCE XR324-4M POE; MANAGED IE SWITCH, 19" RACK; POWER SUPPLY DC 24V; PORTS FRONT SIDE; 8 X 10/100/1000MBIT/S FOR RJ45 PORTS ELECTRICAL WITH POE; 8 X 10/100/1000MBIT/S FOR RJ45 PORTS ELECTRICAL W/O POE; 4 X 10/100/1000MBIT/S 2-PORT MEDIA MODULES, ELECTRICAL OR OPTICAL; LED DIAGNOSIS; FAULT SIGNAL CONTACT; SELECT / SET BUTTON; PROFINET IO DEVICE; |
Transmission rate |
Transfer rate |
10 Mbit/s, 100 Mbit/s, 1000 Mbit/s |
Interfaces |
Number of electrical/optical connections |
|
● for network components or terminal equipment / maximum |
24 |
Number of electrical connections |
|
● for network components or terminal equipment |
16 |
● for Power-over-Ethernet / for network components or terminal equipment |
8 |
● for operator console |
1 |
● for signaling contact |
1 |
● for media module |
4 |
● for power supply |
1 |
● for redundant voltage supply |
1 |
Design of the electrical connection |
|
● for network components or terminal equipment |
RJ45 port |
● for Power-over-Ethernet / for network components or terminal equipment |
RJ45 port |
● for operator console |
RJ11 port |
● for signaling contact |
2-pole terminal block |
● for power supply |
4-pole terminal block |
Design of the optical interface |
|
● for fiber optic cable / at 100 Mbit/s |
Dependent on selected media modules |
● for fiber optic cable / at 1000 Mbit/s |
Dependent on selected media modules |
design of the removable storage / C-PLUG |
Yes |
Signal-Inputs/outputs |
Operating voltage / of the signaling contacts |
|
● for DC / Rated value |
24 V |
Operating current / of the signaling contacts |
|
● for DC / maximum |
0.1 A |
Supply voltage, current consumption, power loss |
Type of voltage supply / redundant power supply unit |
No |
Type of voltage / of the supply voltage |
DC |
Supply voltage |
|
● external |
24 V |
● external |
19.2 ... 28.8 V |
Product component / fusing at power supply input |
Yes |
Fuse protection type / at input for supply voltage |
F 5 A / 250 V |
Consumed current / maximum |
4.2 A |
Active power loss |
|
● for DC / at 24 V |
46 W |
Permitted ambient conditions |
Ambient temperature |
|
● during operation |
-40 ... +60 °C |
● during storage |
-40 ... +85 °C |
● during transport |
-40 ... +85 °C |
● Note |
If the device is installed in the vertical position, the maximum operating temperature is reduced to 60 °C. |
Relative humidity |
|
● at 25 °C / without condensation / during operation / maximum |
95 % |
Protection class IP |
IP20 |
Design, dimensions and weight |
Design |
19" rack |
Number of height units / relating to 19-inch cabinet |
1 |
Width |
449 mm |
Height |
43.6 mm |
Depth |
305 mm |
Net weight |
6.8 kg |
Mounting type |
When used in shipbuilding, the device must be secured in the 19" rack at four points |
● 19-inch installation |
Yes |
● 35 mm DIN rail mounting |
No |
● wall mounting |
No |
● S7-300 rail mounting |
No |
● S7-1500 rail mounting |
No |
Product properties, functions, components / general |
Cascading in the case of a redundant ring / at reconfiguration time of <~0.3~s |
100 |
Cascading in cases of star topology |
Any (depending only on signal propagation time) |
Product functions / management, configuration |
Product function |
|
● CLI |
Yes |
● web-based management |
Yes |
● MIB support |
Yes |
● TRAPs via email |
Yes |
● Configuration with STEP 7 |
Yes |
● RMON |
Yes |
● Port mirroring |
Yes |
● multiport mirroring |
Yes |
● CoS |
Yes |
● PROFINET IO diagnosis |
Yes |
● switch-managed |
Yes |
Protocol / is supported |
|
● Telnet |
Yes |
● HTTP |
Yes |
● HTTPS |
Yes |
● TFTP |
Yes |
● FTP |
Yes |
● BOOTP |
Yes |
● GMRP |
Yes |
● DCP |
Yes |
● LLDP |
Yes |
● IGMP (snooping/querier) |
Yes |
Identification & maintenance function |
|
● I&M0 - device-specific information |
Yes |
● I&M1 – higher-level designation/location designation |
Yes |
Protocol / is supported |
|
● SNMP v1 |
Yes |
● SNMP v2 |
Yes |
● SNMP v3 |
Yes |
Product functions / Diagnosis |
Product function |
|
● Port diagnostics |
Yes |
● Statistics Packet Size |
Yes |
● Statistics packet type |
Yes |
● Error statistics |
Yes |
● SysLog |
Yes |
Product functions / VLAN |
Product function |
|
● VLAN - port based |
Yes |
● VLAN - protocol-based |
No |
● VLAN - IP-based |
No |
● VLAN dynamic |
Yes |
Number of VLANs / maximum |
255 |
Number of VLANs - dynamic / maximum |
255 |
Protocol / is supported / GVRP |
Yes |
Product functions / DHCP |
Product function |
|
● DHCP client |
Yes |
● DHCP Option 82 |
Yes |
● DHCP Option 66 |
Yes |
● DHCP Option 67 |
Yes |
Product functions / Redundancy |
Product function |
|
● Ring redundancy |
Yes |
● High Speed Redundancy Protocol (HRP) |
Yes |
● high speed redundancy protocol (HRP) with redundancy manager |
Yes |
● high speed redundancy protocol (HRP) with standby redundancy |
Yes |
● Media Redundancy Protocol (MRP) |
Yes |
● media redundancy protocol (MRP) with redundancy manager |
Yes |
● redundancy procedure STP |
Yes |
● redundancy procedure RSTP |
Yes |
● redundancy procedure MSTP |
Yes |
● Passive listening |
Yes |
Protocol / is supported |
|
● STP/RSTP |
Yes |
● STP |
Yes |
● RSTP |
Yes |
● MSTP |
No |
● RSTP big network support |
Yes |
● LACP |
Yes |
Product functions / Security |
Product function |
|
● ACL - MAC-based |
Yes |
● ACL - port/MAC-based |
Yes |
● IEEE 802.1x (radius) |
Yes |
● Broadcast/Multicast/Unicast Limiter |
Yes |
● broadcast blocking |
Yes |
Protocol / is supported |
|
● SSH |
Yes |
Product functions / Time |
Product function |
|
● SICLOCK support |
Yes |
Protocol / is supported |
|
● NTP |
Yes |
● SNTP |
Yes |
● IEEE 1588 profile default |
Yes |
Standards, specifications, approvals |
Standard |
|
● for FM |
FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
● for hazardous zone |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
● for safety / from CSA and UL |
UL 60950-1, CSA C22.2 No. 60950-1 |
● for hazardous zone / from CSA and UL |
UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
● for emitted interference |
EN 61000-6-4:2007 (Class A) |
● for interference immunity |
EN 61000-6-2:2006 |
Certificate of suitability |
EN 61000-6-2:2006, EN 61000-6-4:2007 |
● CE marking |
Yes |
● C-Tick |
Yes |
● KC approval |
No |
MTBF / at 40 °C |
15 y |
Further Information / Internet Links |
Internet-Link |
|
● to website: Selector SIMATIC NET SELECTION TOOL |
http://www.siemens.com/snst |
● to website: Industrial communication |
http://www.siemens.com/simatic-net |
● to website: Industry Mall |
https://mall.industry.siemens.com |
● to website: Information and Download Center |
http://www.siemens.com/automation/net/catalog |
● to website: Image database |
http://automation.siemens.com/bilddb |
● to website: CAx Download Manager |
http://www.siemens.com/cax |
● to website: Industry Online Support |
http://support.automation.siemens.com |
Security information |
Security information |
Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4) |
last modified: |
07.11.2014 |
Date 07.11.2014 |
Changes preserved © Copyright Siemens AG 2014 |