6GK5302-7GD00-3EA3 SCALANCE X302-7EEC

Product Code: 6GK5302-7GD00-3EA3

Availability: In Stock

Price: $100,000,000,000.00
Artikelnummer 6GK5302-7GD00-3EA3
Product type designation SCALANCE X302-7EEC
Product description
SCALANCE X302-7EEC; MANAGED IE SWITCH, COMPACT; 2 X 10/100/1000MBIT/S RJ45; 7 X 100MBIT/S LC FO PORTS; 100 - 240 V AC/DC POWER SUPPLY; LED-DIAGNOSTICS, FAULT SIGNAL CONTACT WITH SELECT/SET-BUTTON; PROFINET-IO DEVICE, NETWORK- MANAGEMENT, INTEGRATED REDUNDANCY MANAGER, OFFICE FEATURES (RSTP, VLAN, IGMP,..); C-PLUG IN SCOPE OF SUPPLY
Transmission rate
Transfer rate 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s
Interfaces
Number of electrical/optical connections
● for network components or terminal equipment / maximum 9
Number of electrical connections
● for network components or terminal equipment 2
● for signaling contact 1
● for power supply 1
Design of the electrical connection
● for network components or terminal equipment RJ45 port
● for signaling contact 3-pole terminal block
● for power supply 3-pole terminal block
Number of optical interfaces
● for fiber optic cable / at 100 Mbit/s 7
Design of the optical interface
● for fiber optic cable / at 100 Mbit/s LC port (multimode up to 5 km)
Connectable optical power relative to 1 mW
● of the transmitter output / minimum -19 dB
● of the transmitter output / maximum -14 dB
● of the receiver input / maximum -14 dB
Optical sensitivity relating to 1 mW / of the receiver input / minimum -32 dB
Damping ratio / of the FOC transmission link / minimum necessary 0 dB
Range / at the optical interface / depending on the optical fiber used 0 ... 5 km
design of the removable storage / C-PLUG Yes
Signal-Inputs/outputs
Operating voltage / of the signaling contacts
● with AC / Rated value 276 V
● for DC / Rated value 230 V
Operating current / of the signaling contacts
● with AC / maximum 5 A
● for DC / maximum 0.1 A
Supply voltage, current consumption, power loss
Type of voltage supply / redundant power supply unit No
Type of voltage / of the supply voltage AC
Supply voltage
● with AC 230 V
● with AC / Rated value 80 ... 276 V
Supply voltage / 2 / Rated value
● Type of voltage / 2 / of the supply voltage DC
Supply voltage
● for DC 220 V
● for DC / Rated value / minimum 46.25 V
● for DC / Rated value / maximum 300 V
Product component / fusing at power supply input Yes
Fuse protection type / at input for supply voltage T 2 A / 250 V
Consumed current / maximum 0.08 A
Active power loss
● with AC / at 230 V 18 W
● for DC / at 250 V 18 W
Permitted ambient conditions
Ambient temperature
● during operation -40 ... +70 °C
● during storage -40 ... +70 °C
● during transport -40 ... +70 °C
● Note A maximum operating temperature of +85 °C is permissible for a duration of 16 hours
Relative humidity
● at 25 °C / without condensation / during operation / maximum 95 %
Ambient condition / for operation Conformal coating, no
Coating Conformal Coating, no
Protection class IP IP30
Design, dimensions and weight
Design compact
Width 216 mm
Height 143 mm
Depth 110 mm
Net weight 1.85 kg
Mounting type Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate
● 19-inch installation Yes
● 35 mm DIN rail mounting Yes
● wall mounting Yes
● S7-300 rail mounting Yes
● S7-1500 rail mounting No
Product properties, functions, components / general
Cascading in cases of star topology Any (depending only on signal propagation time)
Product functions / management, configuration
Product function
● CLI Yes
● web-based management Yes
● MIB support Yes
● TRAPs via email Yes
● Configuration with STEP 7 Yes
● RMON Yes
● Port mirroring Yes
● multiport mirroring Yes
● CoS Yes
● with IRT / PROFINET IO switch No
● PROFINET IO diagnosis Yes
● switch-managed Yes
Protocol / is supported
● Telnet Yes
● HTTP Yes
● HTTPS Yes
● TFTP Yes
● FTP Yes
● BOOTP Yes
● GMRP Yes
● DCP Yes
● LLDP Yes
● IGMP (snooping/querier) Yes
Identification & maintenance function
● I&M0 - device-specific information Yes
● I&M1 – higher-level designation/location designation Yes
Protocol / is supported
● SNMP v1 Yes
● SNMP v2 Yes
● SNMP v3 Yes
Product functions / Diagnosis
Product function
● Port diagnostics Yes
● Statistics Packet Size Yes
● Statistics packet type Yes
● Error statistics Yes
● SysLog Yes
Product functions / VLAN
Product function
● VLAN - port based Yes
● VLAN - protocol-based No
● VLAN - IP-based No
● VLAN dynamic Yes
Number of VLANs / maximum 255
Number of VLANs - dynamic / maximum 255
Protocol / is supported / GVRP Yes
Product functions / DHCP
Product function
● DHCP client Yes
● DHCP Option 82 Yes
● DHCP Option 66 Yes
● DHCP Option 67 Yes
Product functions / Redundancy
Product function
● Ring redundancy Yes
● High Speed Redundancy Protocol (HRP) Yes
● high speed redundancy protocol (HRP) with redundancy manager Yes
● high speed redundancy protocol (HRP) with standby redundancy Yes
● Media Redundancy Protocol (MRP) Yes
● media redundancy protocol (MRP) with redundancy manager Yes
● redundancy procedure STP Yes
● redundancy procedure RSTP Yes
● redundancy procedure MSTP Yes
● Passive listening Yes
Protocol / is supported
● STP/RSTP Yes
● STP Yes
● RSTP Yes
● MSTP No
● RSTP big network support Yes
● LACP Yes
Product functions / Security
Product function
● ACL - MAC-based Yes
● ACL - port/MAC-based Yes
● IEEE 802.1x (radius) Yes
● Broadcast/Multicast/Unicast Limiter Yes
● broadcast blocking Yes
Protocol / is supported
● SSH Yes
Product functions / Time
Product function
● SICLOCK support Yes
Protocol / is supported
● NTP Yes
● SNTP Yes
● IEEE 1588 profile default Yes
Standards, specifications, approvals
Standard
● for EMC IEC 61850, IEEE 1613
● for FM -
● for hazardous zone -
● for safety / from CSA and UL UL 508, CSA C22.2 No. 142-M1987
● for hazardous zone / from CSA and UL -
● for emitted interference EN 61000-6-4:2007 (Class A)
● for interference immunity EN 61000-6-2:2005
Certificate of suitability EN 61000-6-2:2005, EN 61000-6-4:2007
● CE marking Yes
● C-Tick Yes
● KC approval Yes
● Railway application in accordance with EN 50155 No
● Railway application in accordance with EN 50124-1 No
● IEC 61850-3 Yes
● IEEE 1613 Yes
MTBF / at 40 °C 22.8 y
Further Information / Internet Links
Internet-Link
● to website: Selector SIMATIC NET SELECTION TOOL http://www.siemens.com/snst
● to website: Industrial communication http://www.siemens.com/simatic-net
● to website: Information and Download Center http://www.siemens.com/automation/net/catalog
● to website: Image database http://automation.siemens.com/bilddb
● to website: CAx Download Manager http://www.siemens.com/cax
● to website: Industry Online Support http://support.automation.siemens.com
Security information
Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4)
last modified: 04.11.2014
Date
06.11.2014
Changes preserved
© Copyright Siemens AG 2014

Write a review

Note: HTML is not translated!

Rating: Bad Good

Enter the code in the box below: