Product type designation |
SCALANCE W788-1RR |
Product description |
|
|
IWLAN ACCESS POINT SCALANCE W788-1RR, FOR USE OUTSIDE OF USA 1 RADIO INTERFACE, IEEE 802.11 B/G/A/H, INDUSTRIAL WIRELESS LAN WITH RAPID ROAMING (IWLAN RR), 2.4/5 GHZ, UP TO 54MBIT/S, WPA2/802.11I/11E, NOTE NATIONAL APPROVALS, POE, IP65(-20-+60 DGR C), EN50155, SCOPE OF SUPPL.:2X ANT 795-4MR, IP67 HYBRID-PLUG CONNECTOR, MOUNTING MAT., MANUAL ON CD-ROM GERMAN / ENGLISH; |
Transmission rate |
Transfer rate |
|
● with WLAN / maximum |
54 Mbit/s |
● for Industrial Ethernet |
10 Mbit/s, 100 Mbit/s |
● Note |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Interfaces |
Number of electrical connections |
|
● for network components or terminal equipment |
1 |
● for power supply |
1 |
● for redundant voltage supply |
1 |
Design of the electrical connection |
|
● for network components or terminal equipment |
Hybrid socket, RJ45 integrated |
● for power supply |
M12 interface (4-pole, A-coded), hybrid socket, PoE |
design of the removable storage |
|
● C-PLUG |
Yes |
● KEY-PLUG |
No |
Interfaces / wireless |
Number of radio cards / permanently installed |
1 |
Number of electrical connections / for external antenna(s) |
2 |
Design of the electrical connection / for external antenna(s) |
R-SMA (socket) |
Product property / external antenna can be mounted directly on device |
Yes |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage |
DC |
Supply voltage / 1 |
|
● from M12 Power Connector (A-coded) for redundant power supply |
24 V |
● from IE Hybrid Cable 2x2 + 4x0.34 |
24 V |
Supply voltage / 2 |
|
● from M12 Power Connector (A-coded) for redundant power supply |
48 V |
● from IE Hybrid Cable 2x2 + 4x0.34 |
48 V |
Supply voltage |
|
● from Power-over-Ethernet acc. to IEEE802.3at for type 1 and IEEE802.3af |
48 V |
Permitted ambient conditions |
Ambient temperature |
|
● during operation |
-20 ... +60 °C |
● during storage |
-40 ... +70 °C |
● during transport |
-40 ... +70 °C |
Relative humidity / at 25 °C / without condensation / during operation / maximum |
100 % |
Ambient condition / for operation |
When used under hazardous conditions (Zone 2), the SCALANCE W788-xPRO/RR or W74x-1PRO/RR product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529. |
Protection class IP |
IP65 |
Design, dimensions and weight |
Width / of the enclosure / without antenna |
125 mm |
Height / of the enclosure / without antenna |
88 mm |
Depth / of the enclosure / without antenna |
108 mm |
Net weight |
1.05 kg |
Mounting type |
|
● S7-300 rail mounting |
Yes |
● S7-1500 rail mounting |
No |
● wall mounting |
Yes |
Wireless frequencies |
Radio frequency |
|
● for WLAN in 2.4 GHz frequency band |
2.41 ... 2.48 GHz |
● for WLAN in 5 GHz frequency band |
4.9 ... 5.8 GHz |
Product properties, functions, components / general |
Product function / Access Point Mode |
Yes |
Product function / Client Mode |
Yes |
Number of SSIDs |
8 |
Product function |
|
● Dual Client |
No |
● iHOP |
No |
● iPCF Access Point |
Yes |
● iPCF client |
Yes |
● iPCF-MC Access Point |
No |
● iPCF-MC client |
No |
Number of iPCF-capable radio modules |
1 |
Product functions / management, configuration |
Number of manageable IP addresses / in client |
8 |
Product function |
|
● CLI |
Yes |
● web-based management |
Yes |
● MIB support |
Yes |
● TRAPs via email |
Yes |
● Configuration with STEP 7 |
No |
● configuration with STEP 7 in the TIA Portal |
Yes |
● operation with IWLAN controller |
No |
● operation with Enterasys WLAN controller |
No |
● iQoS |
Yes |
● forced roaming with IWLAN |
Yes |
● WDS |
Yes |
Protocol / is supported |
|
● Address Resolution Protocol (ARP) |
Yes |
● ICMP |
Yes |
● Telnet |
Yes |
● HTTP |
Yes |
● HTTPS |
Yes |
● TFTP |
Yes |
● DCP |
Yes |
● LLDP |
No |
Identification & maintenance function |
|
● I&M0 - device-specific information |
No |
● I&M1 – higher-level designation/location designation |
No |
Product functions / Diagnosis |
Product function |
|
● PROFINET IO diagnosis |
Yes |
● Link Check |
Yes |
● connection monitoring IP-Alive |
Yes |
● localization via Aeroscout |
No |
● SysLog |
Yes |
Protocol / is supported |
|
● SNMP v1 |
Yes |
● SNMP v2 |
Yes |
● SNMP v3 |
Yes |
Product functions / VLAN |
Product function |
|
● function VLAN with IWLAN |
Yes |
Product functions / DHCP |
Product function |
|
● DHCP client |
Yes |
● in Client Mode / DHCP server via LAN |
Yes |
Product functions / Redundancy |
Protocol / is supported |
|
● STP/RSTP |
Yes |
Product functions / Security |
Product function |
|
● ACL - MAC-based |
Yes |
● Management security, ACL-IP based |
No |
● IEEE 802.1x (radius) |
Yes |
● NAT/NAPT |
Yes |
● access protection according to IEEE802.11i |
Yes |
● WPA/WPA2 |
Yes |
● TKIP/AES |
Yes |
Protocol / is supported |
|
● SSH |
Yes |
Product functions / Time |
Protocol / is supported |
|
● SNTP |
Yes |
● SIMATIC Time |
No |
Standards, specifications, approvals |
Standard |
|
● for hazardous zone |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
● for safety / from CSA and UL |
UL 60950-1 CSA C22.2 No. 60950-1 |
● for hazardous zone / from CSA and UL |
ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 |
Certificate of suitability |
|
● EC declaration of conformity |
Yes |
● CE marking |
Yes |
● C-Tick |
Yes |
● E1 approval |
No |
● Railway application in accordance with EN 50155 |
No |
● NEMA4X |
No |
● Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af |
Yes |
Standard for wireless communication |
|
● IEEE 802.11a |
Yes |
● IEEE 802.11b |
Yes |
● IEEE 802.11e |
Yes |
● IEEE 802.11g |
Yes |
● IEEE 802.11h |
Yes |
● IEEE 802.11i |
Yes |
● IEEE 802.11n |
No |
Wireless approval |
For operation outside the USA, you can find more detailed information at: www.siemens.com/simatic-net/ik-info |
Accessories |
accessories |
2 antennas, hybrid connector included in scope of delivery |
Further Information / Internet Links |
Internet-Link |
|
● to website: Information and Download Center |
http://www.siemens.com/automation/net/catalog |
● to website: Image database |
http://automation.siemens.com/bilddb |
● to website: CAx Download Manager |
http://www.siemens.com/cax |
● to website: Industry Online Support |
http://support.automation.siemens.com |
last modified: |
23.10.2014 |
Date 03.11.2014 |
Changes preserved © Copyright Siemens AG 2014 |