|
SIMATIC NET, CP 142-2 COMMUNICATIONS PROCESSOR FOR CONN. OF SIMATIC ET 200X TO AS-INTERFACE ACCOR. AS-INTERFACE SPEC. V2.0
|
|
General technical data:
|
Product designation | | AS-Interface Master |
Product type designation | | CP 142-2 |
Protection class IP | | IP20 |
Design of the electrical connection / of the AS-interface | | M12 connector |
Type of voltage supply | | via backplane bus |
Operating condition / separate power supply 24 V | | No |
Consumed current | | |
- from profile conductors of the AS-interface
| | |
- at 24 V / with AS-i Power24V / maximum
| mA | 100 |
- from backplane bus / maximum
| mA | 60 |
Active power loss | W | 4.4 |
Insulation voltage / Rated value | V | 500 |
Product function / suitable for AS-i Power24V | | No |
Product property / redundancy capability | | No |
Product function / web-based management | | No |
Product function / Diagnostics via email | | No |
Product function / Galvanic isolation | | Yes |
| | SF, APF, SER, AUP, CM |
Type of configuration / of the AS-interface | | Set pushbutton on device, GSD, command interface |
|
Communication:
|
|
|
Version / of the AS-interface specification | | V 2.0 |
Type of data transmission | | ET 200X backplane bus |
Number of units / per CPU / maximum | | 6 |
Number of interfaces | | |
| | 1 |
| | 0 |
- acc. to Industrial Ethernet
| | 0 |
| | 0 |
| | 0 |
| | 0 |
| | 2 |
Product component / optical interface | | No |
Protocol / is supported | | |
- ASIsafe (Safety at work) protocol
| | No |
| | No |
| | No |
| | No |
| | No |
| | No |
| | No |
Standard for wireless communication / IEEE 802.11 | | No |
|
Ein- und Ausgänge:
|
|
|
Number of inputs / for AS Interface / maximum | | 124 |
Number of outputs / for AS Interface / maximum | | 124 |
Number of AS-i slaves / per AS-Interface / maximum | | 31 |
Bus cycle time / of the AS-interface | | |
| ms | 5 |
| ms | 10 |
Access to digital I/O data | | via process diagram/peripheral addresses and data record transfer |
|
Mechanical design:
|
|
|
Width | mm | 87 |
Height | mm | 110 |
Depth | mm | 63 |
Mounting type | | Screw fixing or ET 200X mounting plate |
Module format | | ET 200X design |
|
Ambient conditions:
|
|
|
Ambient temperature | | |
- if installed on horizontal mounting rail / during operation
| °C | 0…55 |
- if installed on vertical mounting rail / during operation
| °C | 0…55 |
| °C | -40…+70 |
| °C | -40…+70 |
Relative humidity / at 25 °C / during operation / maximum | % | 95 |
Installation altitude / at height above sea level / maximum | m | 2,000 |
|
Safety:
|
|
|
Suitability for use / safety-related function | | No |
Explosion protection marking / for intrinsic safety of related equipment | | |
| | No |
| | No |
Explosion protection category for gas | | none |
Explosion protection category for dust | | none |
|
Certificates/approvals:
|
|
|
General Product Approval |
EMC |
Shipping Approval |
|
|
|
|
|
|
|
|
Further information:
|
Information- and Downloadcenter (Catalogs, Brochures,…)
|
Industry Mall (Online ordering system)
|
Cax online generator:
|
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
|
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
|
|
|
|
|
|
last change:
|
Oct 20, 2014
|